HP rp7405 Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Części komputerowe HP rp7405. HP rp7405 Technical data Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 74
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Site Preparation Guide
hp rp7405/rp7410 Servers
Second Edition
Manufacturing Part Number: A6752-96009
21102
USA
© Copyright 2002
Przeglądanie stron 0
1 2 3 4 5 6 ... 73 74

Podsumowanie treści

Strona 1 - Site Preparation Guide

Site Preparation Guide hp rp7405/rp7410 ServersSecond EditionManufacturing Part Number: A6752-9600921102USA© Copyright 2002

Strona 2 - Legal Notices

viiiRevision HistoryTable 1 RevisionsRevision Part Number Release Date DescriptionSecond A6752-96003 November 2002 Made general updates and correction

Strona 3 - Contents

ixNotational ConventionsWARNING Warnings highlight procedures or information necessary to avoid injury to personnel. The warning should tell the read

Strona 4

xSafety and RegulatoryRegulatory Model: RSVLA-0102For your protection, this product has been tested to various national and international regulations

Strona 5

xiFigure 1 Declaration of Conformity

Strona 6

xiiUSA Radio Frequency Interference FCC NoticeThe Federal Communications Commission (in 47 CFR Part 15 subpart B) has specified that the following not

Strona 7

xiiiKorean RFI StatementCertification Number: E - AAAAA - BB - CCCC• E: EMC registration• AAAAA: equipment codes (RRL notice, 2000.10.26)• BB: certi

Strona 8

xivBSMI (Taiwan Area)This product is fully compliant to CNS 13438 (CISPR 22: 1993) Class A. The EMC label is in the form shown in Figure 4.Figure 4 Ta

Strona 9

xvInstallation ConditionsSee installation instructions before connecting this equipment to the input supply.Voir la notice d’installation avant de ra

Strona 10 - Revision History

xviLithium Battery CautionWARNING Observe the correct polarity when changing the lithium battery. There is a danger of explosion if battery is install

Strona 11 - Notational Conventions

xviiLaser SafetyNOTE If a Fibre Channel I/O card is present, the following laser safety statement applies.This product contains a laser internal to t

Strona 12 - Safety in Material Handling

iiLegal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to thi

Strona 14 - FCC Notice

Chapter 111 System Specifications

Strona 15 - Canada RFI Statement

Chapter 1System SpecificationsDimensions and Weights2Dimensions and WeightsThis section provides dimensions and weights of the system components. Ship

Strona 16 - IT Power System

Chapter 1System SpecificationsElectrical Specifications3Electrical SpecificationsThis section provides electrical specifications for hp rp7405/rp7410

Strona 17 - Installation Conditions

Chapter 1System SpecificationsElectrical Specifications4Future upgrades may increase the Maximum Theoretical System Power to 3400 VA.Maximum power is

Strona 18 - Australian C-Tick Label

Chapter 1System SpecificationsEnvironmental Specifications5Environmental SpecificationsThis section provides the environmental, power dissipation, noi

Strona 19 - Laser Safety

Chapter 1System SpecificationsEnvironmental Specifications6PCI/Mass Storage Section CoolingSix (6) 92mm fans located between the Mass Storage Devices

Strona 20

Chapter 1System SpecificationsEnvironmental Specifications7Figure 1-1 illustrates the location of the inlet and outlet airducts on a single cabinet.Fi

Strona 21 - 1 System Specifications

Chapter 1System SpecificationsEnvironmental Specifications8

Strona 22 - Dimensions and Weights

Chapter 292 Facility Guidelines

Strona 23 - Electrical Specifications

Contentsiii1. System SpecificationsDimensions and Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 24

Chapter 2Facility GuidelinesElectrical Considerations10Electrical ConsiderationsProper design and installation of a power distribution system for an h

Strona 25 - Environmental Specifications

Chapter 2Facility GuidelinesElectrical Load Requirements (Circuit Breaker Sizing)11Electrical Load Requirements (Circuit Breaker Sizing)It is always a

Strona 26 - Air Flow

Chapter 2Facility GuidelinesPower Quality12Power QualityThis equipment is designed to operate over a wide range of voltages and frequencies. It has be

Strona 27 - Figure 1-1 Airflow Diagram

Chapter 2Facility GuidelinesDistribution Hardware13Distribution HardwareThis section describes wire selection and the types of raceways (electrical co

Strona 28 - System Specifications

Chapter 2Facility GuidelinesGrounding Systems14Grounding Systemshp rp7405/rp7410 servers require two methods of grounding:• Power distribution safety

Strona 29 - 2 Facility Guidelines

Chapter 2Facility GuidelinesGrounding Systems15NOTE In some cases power distribution system green (green/yellow) wire ground conductors are too long a

Strona 30 - Electrical Considerations

Chapter 2Facility GuidelinesGrounding Systems16• Good—Use the raised floor structure as a ground grid. In this case, the floor must be designed as a g

Strona 31

Chapter 2Facility GuidelinesSystem Installation Guidelines17System Installation GuidelinesThis section contains information about installation practic

Strona 32 - Power Quality

Chapter 2Facility GuidelinesEnvironmental Elements18Environmental Elements The following environmental elements can affect an hp rp7405/rp7410 server

Strona 33 - Distribution Hardware

Chapter 2Facility GuidelinesEnvironmental Elements19At altitudes above 5,000 feet (3048 m), the lower air density reduces the cooling capability of ai

Strona 34 - Grounding Systems

ContentsivFacility Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 35

Chapter 2Facility GuidelinesEnvironmental Elements20• Underfloor air distribution system—Downflow air conditioning equipment located on the raised flo

Strona 36

Chapter 2Facility GuidelinesEnvironmental Elements21CAUTION Low humidity contributes to undesirably high levels of electrostatic charges. This increas

Strona 37 - Data Communications Cables

Chapter 2Facility GuidelinesEnvironmental Elements22Special precautions are necessary if the computer room is near a source of air pollution. Some air

Strona 38 - Environmental Elements

Chapter 2Facility GuidelinesEnvironmental Elements23AcousticsComputer equipment and air conditioning blowers cause computer rooms to be noisy. Ambient

Strona 39 - Air Conditioning System Types

Chapter 2Facility GuidelinesComputer Room Safety24Computer Room SafetyInside the computer room, fire protection and adequate lighting (for equipment s

Strona 40 - Humidity Level

Chapter 2Facility GuidelinesFacility Characteristics25Facility CharacteristicsThis section contains information about facility characteristics that mu

Strona 41 - Dust and Pollution Control

Chapter 2Facility GuidelinesFacility Characteristics26Average Floor LoadingThe average floor load value, defined in Table 2-4, is not appropriate for

Strona 42

Chapter 2Facility GuidelinesFacility Characteristics27WindowsAvoid housing computers in a room with windows. Sunlight entering a computer room may cau

Strona 43 - Acoustics

Chapter 2Facility GuidelinesSpace Requirements28Space RequirementsThis section contains information about space requirements for an hp rp7405/rp7410 s

Strona 44 - Computer Room Safety

Chapter 2Facility GuidelinesSpace Requirements29The service area space requirements, shown in Figure 2-3, are minimum dimensions. If other equipment i

Strona 45 - Facility Characteristics

TablesvTable 1. Revisions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 46

Chapter 2Facility GuidelinesZinc Particle Contamination30Zinc Particle ContaminationMetallic particulates can be especially harmful around electronic

Strona 47

Chapter 3313 Pre-installation SurveyThis chapter provides a site survey information packet consisting of an information form and checklists to be used

Strona 48 - Space Requirements

Chapter 3Pre-installation SurveyPre-installation Survey Content32Pre-installation Survey ContentThe site Pre-installation survey information is design

Strona 49 - Figure 2-3 Footprint

Chapter 3Pre-installation SurveyTypical Installation Schedule33Typical Installation ScheduleThe following schedule lists the sequence of events for a

Strona 50 - Zinc Particle Contamination

Chapter 3Pre-installation SurveySite Inspection34Site InspectionTable 3-1 contains the basic Customer and Hewlett-Packard information.Table 3-2 contai

Strona 51 - 3 Pre-installation Survey

Chapter 3Pre-installation SurveySite Inspection356. Is the raised floor adequate for equipment loading?7. Are there channels or cutouts for cable rou

Strona 52

Chapter 3Pre-installation SurveySite Inspection3622. Is there an emergency power shut-off switch?23. Is there a telephone available for emergency purp

Strona 53 - Typical Installation Schedule

Chapter 3Pre-installation SurveyDelivery Survey37Delivery SurveyThe delivery survey form shown in Figure 3-1 on page 38 and Figure 3-2 on page 39 list

Strona 54 - Site Inspection

Chapter 3Pre-installation SurveyDelivery Survey38• Special security requirements applicable to the facility, such as security clearanceFigure 3-1 Deli

Strona 55

Chapter 3Pre-installation SurveyDelivery Survey39Figure 3-2 Delivery Survey (Part 2)DepthWidthWidthWidthSTAIRSWidthELEVATORHeightFill in the following

Strona 56

Tablesvi

Strona 57 - Delivery Survey

Chapter 3Pre-installation SurveyDelivery Survey40

Strona 58 - DELIVERY CHECKLIST

Appendix A41A System Requirements SummaryThis appendix summarizes the requirements that must be considered in preparing the site for the hp rp7405/rp7

Strona 59 - Pre-installation Survey

Appendix ASystem Requirements SummaryPower Consumption and Air Conditioning42Power Consumption and Air ConditioningTo determine the power consumed and

Strona 60

Appendix ASystem Requirements SummaryPower Consumption and Air Conditioning43Table A-1 Example Power Consumption (Theoretical Maximum) and Air Conditi

Strona 61 - A System Requirements Summary

Appendix ASystem Requirements SummaryPower Consumption and Air Conditioning Requirement44Power Consumption and Air Conditioning Requirement Table A-3

Strona 62

Appendix ASystem Requirements SummaryPower Consumption and Air Conditioning Requirement45Maximum power is the sum of the worst case power consumption

Strona 63 - Requirement Summary

Appendix ASystem Requirements SummaryWeight46WeightTo determine overall weight, follow the examples in Table A-5, then complete the entries in Table A

Strona 64

Appendix B47B TemplatesThis appendix contains blank floor plan grids and equipment templates. Combine the necessary number of floor plan grid sheets t

Strona 65

Appendix BTemp l at e s48Figure B-1 illustrates the overall dimensions required for an hp rp7405/rp7410 system.Figure B-1 hp rp7405/rp7410 Space Requi

Strona 66 - Table A-6 Weigh t Summary

Appendix BTem pla t esEquipment Footprint Templates49Equipment Footprint TemplatesEquipment footprint templates are drawn to the same scale as the flo

Strona 67 - B Templates

FiguresviiFigure 1. Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi

Strona 68 - Temp l at e s

Appendix BTemp l at e sComputer Room Layout Plan50Computer Room Layout PlanUse the following procedure to create a computer room layout plan:Step 1. R

Strona 69 - Equipment Footprint Templates

Appendix BTem pla t esComputer Room Layout Plan51Step 5. Position pieces until the desired layout is obtained; then fasten the pieces to the grid. Mar

Strona 70 - Computer Room Layout Plan

Appendix BTemp l at e sComputer Room Layout Plan52Figure B-3 Planning GridScale: 1/4 inch = 1 foot12/20/9960SP016A

Strona 71

53IndexAAC frequency specifications, 4AC power specifications, 3acoustics, 22air conditioning, 19system recommendations, 19air conditioning ducts, 21a

Strona 72 - Figure B-3 Planning Grid

Index54power distribution systemdistribution hardware, 13power quality, 12power system protection, 12power wiring, 13, 17preinstallation survey, 31Rra

Strona 73

Figuresviii

Strona 74

Preface

Komentarze do niniejszej Instrukcji

Brak uwag