The HP ProLiant DL380 G6 Server continues to deliver on its heritage of engineering excellence with increased flexibility and
performance, enterprise-class uptime and manageability, 2-socket Intel Xeon performance, and 2U density for a variety of
applications.
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Quick removal access panel
1.
PCI slot 5
2.
Intel Quad-Core Processor (Performance models include
two processors)
2.
PCI slot 6
3.
PCI slot 4
3.
Second Intel Quad-Core Processor
4.
PCI slot 2
4.
Eighteen slots: DDR3 Registered (RDIMM) or Unbuffered
(UDIMM) memory
5.
PCI slot 3
6.
PCI slot 1
7.
Power supply 2
5.
Hot-plug fans, full N+1 redundancy
8.
Power supply 1
6.
Slim Optical Bay (SATA DVD-RW Optical Drive included
on Performance models)
9.
USB connectors (2)
10.
Video connector
7.
UID LED button
11.
NIC 1 connector
8.
Health LED
12.
NIC 2 connector
9.
Power On/Standby button and system power LED
13.
Mouse connector
10.
USB connectors (2)
14.
Keyboard connector
11.
Video connector
15.
Serial connector
12.
Systems Insight Display
16.
iLO 2 connector
17.
NIC 3 connector
18.
NIC 4 connector
What's New
What's NewWhat's New
What's New
The DL380 G6 will now offer the Intel 5600 Series 6 Core capable processors
X5670 2.93GHz 6C 95w
X5660 2.80GHz 6C 95w
X5650 2.66GHz 6C 95w
QuickSpecs
HP ProLiant DL380 Generation 6 (G6)
HP ProLiant DL380 Generation 6 (G6)HP ProLiant DL380 Generation 6 (G6)
HP ProLiant DL380 Generation 6 (G6)
Overview
DA - 13234 Worldwide — Version 44 — October 14, 2011
Page 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 61 62

Podsumowanie treści

Strona 1 - QuickSpecs

The HP ProLiant DL380 G6 Server continues to deliver on its heritage of engineering excellence with increased flexibility andperformance, enterprise-c

Strona 2

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight ControlHP Insight Contr

Strona 3

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster PlatformsHP Cluster PlatformsHP Cluster Pla

Strona 4

Service and SupportService and SupportService and SupportService and SupportHP Care Pack Services: Packaged server and storage services for increased

Strona 5

Recommended HP Care Pack Services for optimal satisfaction with your HP productRecommended HP Care Pack Services for optimal satisfaction with your HP

Strona 6

Optional HP Care Pack Services that will enhance your HP product experienceOptional HP Care Pack Services that will enhance your HP product experience

Strona 7

X 7, so you can spend less time solving problems and more time focused on your business. You canhave your systems remotely monitored for hardware fail

Strona 8

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Strona 9

Quad-Core ModelsQuad-Core ModelsQuad-Core ModelsQuad-Core ModelsHP DL380G6 X5560HP DL380G6 X5560HP DL380G6 X5560HP DL380G6 X5560470065-067 US470065-07

Strona 10

High Efficiency ModelsHigh Efficiency ModelsHigh Efficiency ModelsHigh Efficiency ModelsQuad-Core ModelsQuad-Core ModelsQuad-Core ModelsQuad-Core Mode

Strona 11

Country Code KeyCountry Code KeyCountry Code KeyCountry Code Keyxx=00U.S.xx=20Brazilxx=29Japanxx=37APDxx=42Europexx=AAPRCQuickSpecsHP ProLiant DL380 G

Strona 12

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Strona 13

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Strona 14

HP DL380 G7 Intel® Xeon® X5660 (2.80GHz/6-core/12MB/95W) FIO ProcessorKit587491-L21HP DL380 G7 Intel® Xeon® X5670 (2.93GHz/6-core/12MB/95W) FIO Proces

Strona 15

Power Advisor is run to determine the right size power supply for your serverconfiguration. The HP Power Advisor is located at: www.hp.com/go/hppowera

Strona 16

2nd processor750-watt redundant power supply512MB cache module for P410i650 mAh P-Series Battery15P 24in SFP Battery Cable AssyOne DL380 G6 HP Fan kit

Strona 17

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. Contact your local sales representative for additional information.HP Unique O

Strona 18

HP MemoryHP MemoryHP MemoryHP MemoryRegistered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)HP 2GB (1x2GB)

Strona 19

HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty HardDrive512547-B21HP 146GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterpris

Strona 20

HP 60GB 3G SATA LFF (3.5-inch) Midline 1yr Warranty Solid State Drive570761-B21HP 120GB 3G SATA LFF (3.5-inch) Midline 1yr Warranty Solid State Drive5

Strona 21

HP Power SuppliesHP Power SuppliesHP Power SuppliesHP Power SuppliesNOTE:NOTE:NOTE:NOTE: Prior to making a power supply selection it is highly recomme

Strona 22

HP Insight SoftwareHP Insight SoftwareHP Insight SoftwareHP Insight SoftwareHP Insight ControlHP Insight ControlHP Insight ControlHP Insight Control H

Strona 23

UpgradeabilityUpgradeabilityUpgradeabilityUpgradeabilityUpgradeable to 2 processors (12 cores)Memory ProtectionMemory ProtectionMemory ProtectionMemor

Strona 24

HP iLO Advanced including 1yr 24x7 Technical Support and Updates ElectronicLicenseTA850AAEHP iLO Advanced including 1yr 24x7 Technical Support and Upd

Strona 25

HP High Performance Computing Linux Value Pack 1 Processor Flexible LicenseNOTE:NOTE:NOTE:NOTE: This part number can be used to purchase one certifica

Strona 26

HP Smart Array P212/256 1-ports Int/1-ports Ext PCIe x8 SAS Controller462834-B21Smart Array P410 ControllerSmart Array P410 ControllerSmart Array P410

Strona 27

http://h18000.www1.hp.com/products/quickspecs/13202_div/13202_div.html(Smart Array P411 Controller)http://h18000.www1.hp.com/products/quickspecs/13558

Strona 28

HP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoverySoftwareSoftwareSoftwareSoftwareHP Data Protector Expr

Strona 29

HP Disk BackupHP Disk BackupHP Disk BackupHP Disk BackupNOTE:NOTE:NOTE:NOTE: For the complete range of StorageWorks D2D Backup Systems see:http://www.

Strona 30

HP StorageWorks FC1242SR 4Gb PCIe DC Host Bus AdapterAE312AStorageWorks SCSI HBAStorageWorks SCSI HBAStorageWorks SCSI HBAStorageWorks SCSI HBA HP Sto

Strona 31

HP R5500 6000VA INTL 3U Rackmount Uninterruptible Power SystemAF416AHP R5500 5000kVA NA/JP 3U Rackmount Uninterruptible Power SystemAF426ANOTE:NOTE:NO

Strona 32

Management page. Under Power Cords, click on the "HP Power Cord Matrix" link.That link will list cable descriptions, requirements, and speci

Strona 33

HP TFT7600 G2 KVM Console Rackmount Keyboard DE MonitorAZ872AHP TFT7600 G2 KVM Console Rackmount Keyboard FR MonitorAZ873AHP TFT7600 G2 KVM Console Ra

Strona 34

* Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the actual busassignment number** Indicates the number of physical e

Strona 35

0x2x16 KVM Server Console G2 Switch with Virtual Media and CACAF618A0x2x32 KVM Server Console G2 Switch with Virtual Media and CACAF619ANOTE:NOTE:NOTE

Strona 36

NOTE:NOTE:NOTE:NOTE: For more information, customer/resellers can contact:http://www.hp.com/services/carepack QuickSpecsHP ProLiant DL380 Generation 6

Strona 37

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".DDR3 memory population guidelinesDDR3 memory p

Strona 38

If you do mix DIMM speeds, the memory bus will default to the minimum clock rate of all DIMMs in the system - even if theslower DIMM is on the other p

Strona 39

Standard memory plus optional memory (1 CPU model)Standard memory plus optional memory (1 CPU model)Standard memory plus optional memory (1 CPU model)

Strona 40

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 2GB DIMM2D; empty3A; 2GB DIMM3A; em

Strona 41

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 4GB DIMM2D; 4GB DIMM3A; 4GB DIMM3A;

Strona 42

Following are memory options available from HP:Following are memory options available from HP:Following are memory options available from HP:Following

Strona 43

1-8Eight SFF SAS hot plug hard drive bays1-16Sixteen SFF SAS hot plug hard drive baysNOTE:NOTE:NOTE:NOTE: This configuration does not support opticald

Strona 44

SAS Hot Plug LFF (3.5-inch) Enterprise (ENT) DrivesSAS Hot Plug LFF (3.5-inch) Enterprise (ENT) DrivesSAS Hot Plug LFF (3.5-inch) Enterprise (ENT) Dri

Strona 45

1PCIe Gen2x16 x1613Full Length,Full HeightslotSupports upto 150W;single widecards only* Default bus assignment (in decimal). Inserting cards with PCI

Strona 46

160GB 3G SATA 7.2KHP Smart Array P212/Zero Memory ControllerHP Smart Array P212/ 256 MB ControllerHP Smart Array P410/256 MB ControllerHP Smart Array

Strona 47

HP Smart Array P410/512 MB FBWC ControllerHP Smart Array P410/1G FBWC ControllerHP Smart Array P411/256 MB ControllerHP Smart Array P411/512 MB BBWC C

Strona 48

External StorageExternal StorageExternal StorageExternal Storage QuantityQuantityQuantityQuantitySupportedSupportedSupportedSupportedPositionPositionP

Strona 49

PositionPositionPositionPositionSupportedSupportedSupportedSupportedControllerControllerControllerControllerPart NumberPart NumberPart NumberPart

Strona 50

HP StorageWorks SASHP StorageWorks SASHP StorageWorks SASHP StorageWorks SASTape Autoloaders andTape Autoloaders andTape Autoloaders andTape Autoloade

Strona 51

HP 460W HE 12V Hot Plug AC Power Supply KitHP 460W HE 12V Hot Plug AC Power Supply KitHP 460W HE 12V Hot Plug AC Power Supply KitHP 460W HE 12V Hot Pl

Strona 52

HP 1200W 12V Hot Plug AC Power SupplyHP 1200W 12V Hot Plug AC Power SupplyHP 1200W 12V Hot Plug AC Power SupplyHP 1200W 12V Hot Plug AC Power SupplyPa

Strona 53

HP 1200W-48V DC Common Slot Power SupplyHP 1200W-48V DC Common Slot Power SupplyHP 1200W-48V DC Common Slot Power SupplyHP 1200W-48V DC Common Slot Po

Strona 54

System UnitSystem UnitSystem UnitSystem UnitDimensions Dimensions Dimensions Dimensions (H x W x D)(with bezel)SFF Drives: 3.38 x 17.54 x 27.25 in (8.

Strona 55

750 W (at 200 to 240 VAC)For 460 W Power Supply:460 W (at 100 to 120 VAC),460 W (at 200 to 240 VAC)Maximum Peak PowerFor 1200 W Power Supply:800 W (at

Strona 56

InterfacesInterfacesInterfacesInterfacesSerial1Video2 (1 front, 1 back)Network RJ-454iLO remote managementport1Keyboard1Pointing Device (Mouse)1Graphi

Strona 57

LWAd4.1 B 4.7 BLpAm22 dBA 28 dBAEmissions ClassificationEmissions ClassificationEmissions ClassificationEmissions Classification(EMC)(EMC)(EMC)(EMC)FC

Strona 58

HP NC382i Dual PortHP NC382i Dual PortHP NC382i Dual PortHP NC382i Dual PortMultifunction GigabitMultifunction GigabitMultifunction GigabitMultifuncti

Strona 59

Client Browser SupportClient Browser SupportClient Browser SupportClient Browser SupportMicrosoft Internet Explorer 7Microsoft Internet Explorer 6Fire

Strona 60

consumers in an effort to bring energy efficient technology solutions to the marketplace. 80 Plusindependently tests power supply efficiency and publi

Strona 61

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight FoundationManaging the

Strona 62

WarrantyWarrantyWarrantyWarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authori