HP 600911-041 Arkusz Danych

Przeglądaj online lub pobierz Arkusz Danych dla Serwery HP 600911-041. HP ProLiant 600911-041 server Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 52
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
The HP ProLiant ML330 G6 is a dual processor tower platform built on the latest Intel Xeon processors with QPI technology to create
unique system architecture. This unique architecture allows the businesses to scale their businesses as needed so they can optimize
their IT spending dollars. The HP ProLiant ML330 G6 delivers to businesses the industry's most powerful embedded management
technology with the HP Integrated Lights-Out 2 (iLO 2) allowing them to manage the servers anytime and from anywhere.
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Power supply
1.
Power supply 1
2.
Expansion slots
2.
Optional power supply for redundancy
3.
First processor socket
3.
Expansion slots
4.
Nine DIMM slots (for 1
st
processor)
4.
UID button/LED
5.
Video port
5.
Video ports
6.
Hard drive bays 5-8
6.
USB ports (4)
7.
Hard drive bays 1-4
7.
PS/2 keyboard port
8.
LED indicators and power button
8.
PS/2 mouse port
9.
USB connectors (2)
9.
Network port 1 (shared iLO management port)
10.
Removable media bays (2)
10.
Network port 2
11.
Optical drive bay
11.
Serial port
12.
Front system fans (2)
12.
Dedicated iLO2 management port (optional)
QuickSpecs
HP ProLiant ML330 Generation 6 (G6)
HP ProLiant ML330 Generation 6 (G6)HP ProLiant ML330 Generation 6 (G6)
HP ProLiant ML330 Generation 6 (G6)
Overview
DA - 13361 North America — Version 46 — November 14, 2011
Page 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - QuickSpecs

The HP ProLiant ML330 G6 is a dual processor tower platform built on the latest Intel Xeon processors with QPI technology to createunique system arch

Strona 2

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Strona 3

Standard CareStandard CareStandard CareStandard CareStandard Care Package: Package that maintains high level of server availabilityStandard Care Packa

Strona 4

NOTE: NOTE: NOTE: NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information

Strona 5

Quad-Core ModelsQuad-Core ModelsQuad-Core ModelsQuad-Core ModelsHP ProLiant ML330 G6HP ProLiant ML330 G6HP ProLiant ML330 G6HP ProLiant ML330 G6E5506

Strona 6

Optical DriveOptical DriveOptical DriveOptical DriveHP Half-Height SATA DVD-ROM Optical DrivePower SupplyPower SupplyPower SupplyPower Supply460 Watt

Strona 7

The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind,offered at discounte

Strona 8

S-Buy ML330G6 E5520S-Buy ML330G6 E5520S-Buy ML330G6 E5520S-Buy ML330G6 E5520HP 2x250GB SATA SBSHP 2x250GB SATA SBSHP 2x250GB SATA SBSHP 2x250GB SATA S

Strona 9

S-Buy ML330G6 E5507S-Buy ML330G6 E5507S-Buy ML330G6 E5507S-Buy ML330G6 E5507HP 1x146GB SAS ServerHP 1x146GB SAS ServerHP 1x146GB SAS ServerHP 1x146GB

Strona 10

Storage ControllerStorage ControllerStorage ControllerStorage ControllerEmbedded HP Smart Array B110i SATA RAID Controller Hot plug advancedpack (RAID

Strona 11

NOTE: NOTE: NOTE: NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are

Strona 12

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Strona 13

HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 LowPower Memory KitNOTE:NOTE:NOTE:NOTE: Low Voltage DIMMs can only be used with In

Strona 14

Step 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integrat

Strona 15

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Strona 16

HP MemoryHP MemoryHP MemoryHP MemoryRegistered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)HP 2GB (1x2GB)

Strona 17

HP Optical DrivesHP Optical DrivesHP Optical DrivesHP Optical DrivesHP Half-Height SATA DVD-ROM Optical Drive447326-B21HP Half-Height SATA DVD-RW Opti

Strona 18

HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty HardDrive507774-B21HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midlin

Strona 19

HP NC523SFP 10Gb 2-port Server Adapter593717-B21HP NC550SFP Dual Port 10GbE Server Adapter581201-B21NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for

Strona 20

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Strona 21

http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.htmlHP Integrated Lights-Out (iLO) AdvancedHP Integrated Lights-Out (iLO) AdvancedHP I

Strona 22

HP Smart Array P800/512 BBWC 2-ports Int/2-ports Ext PCIe x8 SAS Controller381513-B21Smart Array P212 ControllerSmart Array P212 ControllerSmart Array

Strona 23

Memory ProtectionMemory ProtectionMemory ProtectionMemory ProtectionMirroringLock-step modeAdvanced ECCOnline Spare (Requires X5600 or E5600 processor

Strona 24

(Smart Array P800 Controller)http://h18000.www1.hp.com/products/quickspecs/13203_na/13203_na.html(Smart Array P212 Controller)http://h18000.www1.hp.co

Strona 25

Tape BackupTape BackupTape BackupTape BackupNOTE:NOTE:NOTE:NOTE: For the complete range of tape drives, autoloaders, libraries and media see:http://ww

Strona 26

Disk BackupDisk BackupDisk BackupDisk BackupNOTE:NOTE:NOTE:NOTE: For the complete range of D2D Backup Systems see:http://www.hp.com/go/d2d. For the co

Strona 27

HP Disk Storage SystemsHP Disk Storage SystemsHP Disk Storage SystemsHP Disk Storage SystemsMSA SAN Storage ArraysMSA SAN Storage ArraysMSA SAN Storag

Strona 28

HP Rack SeriesHP Rack SeriesHP Rack SeriesHP Rack SeriesHP Rack 10000 G2 SeriesHP Rack 10000 G2 SeriesHP Rack 10000 G2 SeriesHP Rack 10000 G2 Series (

Strona 29

NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/13

Strona 30

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".DDR3 memory population guidelinesDDR3 memory p

Strona 31

3 DIMM Per Channel800 800 800 800 800n/a n/a n/a n/a n/aNOTES:NOTES:NOTES:NOTES:PC3-10600 DIMMs have a maximum speed of 1333MHz. PC3-8500 DIMMs have a

Strona 32

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; empty2D; empty3A; 2GB RDIMM3A; empt

Strona 33

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 16GB RDIMM2D; empty3A; 16GB RDIMM3A

Strona 34

Storage ControllerStorage ControllerStorage ControllerStorage ControllerEntry ModelsNon hot plug SATA model with HP Smart Array B110i SATA RAID Contro

Strona 35

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 16GB RDIMM2D; 16GB RDIMM3A; 16GB RD

Strona 36

Following are memory options available from HP:Following are memory options available from HP:Following are memory options available from HP:Following

Strona 37

AOptical DriveB,CRemovable Media Bays (2)- 1 full-height drive or 2 half-height drives1-44 x 3.5" (LFF) Hot plug or Non hot-plug SATA/SAS harddri

Strona 38

HP Smart Array P410/512 MB BBWC ControllerHP Smart Array P410/512 MB FBWC ControllerHP Smart Array P410/1G FBWC ControllerHP Smart Array P411/256 MB C

Strona 39

1TB 3G SATA 7.2K500GB 3G SATA 7.2KHP Smart Array P212/ 256 MB ControllerHP Smart Array P410/256 MB ControllerHP Smart Array P410/512 MB BBWC Controlle

Strona 40

250GB 3G SATA 15K160GB 3G SATA 15KUp to 41-4Embedded Smart Array B110i SATA RAID ControllerHP Smart Array P800/512 BBWC ControllerHP Smart Array P212/

Strona 41

LTO-3 Ultrium 920LTO-3 Ultrium 960LTO4 Ultrium 1760LTO-4 Ultrium 1840DAT 40DAT 72DAT 160HP U320e SCSI Dual Channel Host Bus AdapterAH627ANOTE:NOTE:NOT

Strona 42

HP SAS Tape AutoloadersHP SAS Tape AutoloadersHP SAS Tape AutoloadersHP SAS Tape Autoloadersand Libraries, Externaland Libraries, Externaland L

Strona 43

HP 460W Factory Integrated Power Supply KitHP 460W Factory Integrated Power Supply KitHP 460W Factory Integrated Power Supply KitHP 460W Factory Integ

Strona 44

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions(H x W x D)(W/O foot stand)7.87 x 16.81 x 24.13 in (200 x 427 x 61

Strona 45

Server Power CordsServer Power CordsServer Power CordsServer Power CordsNOTE: NOTE: NOTE: NOTE: If customers require a power cord, they can check the

Strona 46

Non-operating**10% to 95% relative humidity (Rh), 101.7°F(38.7°C) maximum wet bulb temperature, non-condensing.AltitudeAltitudeAltitudeAltitudeOperati

Strona 47

HP Smart Array B110iHP Smart Array B110iHP Smart Array B110iHP Smart Array B110iSATA RAID ControllerSATA RAID ControllerSATA RAID ControllerSATA RAID

Strona 48

Embedded NC326i PCIEmbedded NC326i PCIEmbedded NC326i PCIEmbedded NC326i PCIExpress Dual Port GigabitExpress Dual Port GigabitExpress Dual Port Gigabi

Strona 49

Form FactorForm FactorForm FactorForm FactorTower (5U)NOTE:NOTE:NOTE:NOTE: Rack mounting available via HP Tower to Rack Conversion Tray, Universal Kit

Strona 50

Intelligent ManageabilityIntelligent ManageabilityIntelligent ManageabilityIntelligent ManageabilityHP Systems Insight ManagerSmartStartRedundant ROMS

Strona 51

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight ControlHP Insight Contr

Strona 52

Factory Express PortfolioFactory Express PortfolioFactory Express PortfolioFactory Express Portfoliofor Servers and Storagefor Servers and Storagefor

Komentarze do niniejszej Instrukcji

Brak uwag