HP 5992-3193 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie HP 5992-3193. HP 5992-3193 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Linux User's Guide

HP Insight Foundation Suite for Integrity withLinux User's GuideHP Smart SetupHP Support PackHP Part Number: 5992-3193Published: September 2009Ed

Strona 2

— For additional information on HP products and services, see the HP website:http://www.hp.com— For the location of the nearest sales office, call:In

Strona 3 - Table of Contents

1 Planning the InstallationInstalling the Linux operating system (OS) on an HP Integrity server involves preparing thehardware for the OS installation

Strona 4 - 4 Table of Contents

The following table provides the minimum RHEL and SLES OS distributions that are supportedusing the latest HP Insight Foundation Suite for Integrity w

Strona 5 - Table of Contents 5

2. Click Linux certification and support matrices.3. Select the appropriate Linux distribution tab, locate the server name of interest, and thenclick

Strona 6

Using a Serial ConsoleA serial console is a PC running terminal emulation software, such as a Secure SHell (SSH) clientlike PuTTY (available from the

Strona 7 - About This Document

Using the HP Smart Setup EBSU UtilityYou can use HP Smart Setup both before and after the OS is installed.HP recommends that you obtain the latest ver

Strona 8 - Publishing History

Figure 1-3 Installation OverviewThere are minor differences in the sequence of tasks or the interface you use to perform thembased on your choice of c

Strona 9 - Related Information

2 Preparing for InstallationPreparing your server for an OS installation involves setting up a console (VGA, serial, or both)and preparing the hardwar

Strona 10 - HP Encourages Your Comments

5. Verify existing device compatibility at the HP Integrity server connectivity website:http://www.hp.com/go/serverconnectivity6. Verify storage compa

Strona 11 - 1 Planning the Installation

3. Use the Keyboard Configuration Panel to map the Backspace character to Ctrl-H.4. Boot the server.5. Run the terminal emulator and press Enter.The M

Strona 12 - Support Exceptions

© Copyright 2007–2009 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or c

Strona 13

2. Make a list of all device connections so you can reconnect them after the installation iscompleted.3. Disconnect all mass storage devices from all

Strona 14 - Using a VGA Console

5. Change directories to \EFI\boot, and then enter the following:# bootia64.efiThe Smart Setup EBSU entry is created in the EFI Boot Manager as a sele

Strona 15 - Installation Process

11. Change directories to \EFI\boot, and then enter the following:# bootia64.efiThe Smart Setup EBSU entry is created in the EFI Boot Manager as a sel

Strona 16 - 16 Planning the Installation

3 Installing the OS and Updating the ServerThis chapter provides instructions for installing Linux using the HP Smart Setup EBSU utilityor a cold inst

Strona 17 - 2 Preparing for Installation

NOTE: The entry Smart Setup EBSU (if configured) are not displayed in all EFI BootManagers. If this entry does not appear, perform the steps detailed

Strona 18 - Setting Up a Console

Based on the type of server, the option to configure either the Advanced Configuration andPower Interface (ACPI) or maximum payload size (MPS) setting

Strona 19 - Preparing the Server Hardware

NOTE: This setting cannot be changed for the rx2660, rx3600, and rx6600 PCI-X servers,therefore, this menu option is not available.5. Select Configure

Strona 20 - Enabling a CD/DVD Device

NOTE: If you have just configured a RAID volume, then you must reboot the system sothat it is detected. Additionally, on rx7620 and rx8620 servers, yo

Strona 21 - Enabling a USB Device

Figure 3-10 Page 1: Update Firmware, Cell-Based ServersFor either server type, all hardware devices present are listed and automatically selected ifup

Strona 22 - 22 Preparing for Installation

13. Make the appropriate selections for the options on Smart Setup Page 2 as follows:a. For question 2, specify the logical volume on which you want t

Strona 23

Table of ContentsAbout This Document...7Addition

Strona 24

18. A prompt is displayed with a message directing you to insert the Linux installer media inthe CD or DVD drive, as shown in Figure 3-13.IMPORTANT: I

Strona 25

To install the OS, follow these steps:1. Begin the OS installation as described in the installation guide for the OS you are installing.2. Select the

Strona 26

Installing the Fibre Channel HBA Drivers for LinuxIf your system contains Fibre Channel Host Bus Adapters (HBAs), you should ensure that themost curre

Strona 27

Output of lspci CommandAdapter Part No.Fibre Channel: Emulex Corporation Helios-X LightPulse Fibre ChannelHost Adapter (rev 01)AD168AFibre Channel: QL

Strona 28

5. Click on the appropriate Linux distribution link.All of the available driver and software updates are provided in a categorized listing foryour sel

Strona 29

4 EFI and HP Smart Setup Media UtilitiesThis chapter describes functions available through the HP Smart Setup EBSU utility and providesan easy-to-use

Strona 30

Figure 4-1 EFI Boot ManagerEFI ShellAvailable as a selection from the EFI Boot Manager, the EFI Shell provides a command-lineinterface from which you

Strona 31 - Updating the Server

The HP Smart Setup EBSU utility provides the following capabilities:• Configure Storage Adapters—Configures bootable I/O adapters. A submenu provides

Strona 33

5 Installing and Using the HP Support PackThis chapter provides instructions for installing and using the HP Support Pack. This contentsof this softwa

Strona 34

EFI Boot Manager...35EFI Shel

Strona 35 - Using EFI

For more information, see HP Insight Management Agents for Linux on HP Integrity Servers:Installation Guide and Release Notes:http://www.docs.hp.com/e

Strona 36 - HP Smart Setup Utilities

HP Array Configuration Utility – Command Line InterfaceHP Array Configuration Utility – Command Line Interface (ACU-CLI) for Linux on Itanium-basedsys

Strona 37 - HP Smart Setup Utilities 37

When HP Utilization Provider is installed, it launches the utild daemon, which consumesminimal CPU, memory, and disk resources. Only 30 days of utiliz

Strona 38

NOTE: The Management media installer automatically checks your system for the hpmgmtbasesoftware. This software is installed or updated by default.Rem

Strona 39 - HP Insight Management Agents

1. If your system is running RHEL5U1, you must disable SELinux before installing the BEAJRockit 5.0 JDK. Otherwise, bypass this step.# echo 0 >/sel

Strona 40 - HP nPartition Commands

Running the InstallerYou can run the installer anytime after the OS has been installed; however, HP recommends thatyou run the installer immediately a

Strona 41 - Small Footprint CIM Broker

Menu for RHEL4:1. Install HP Insight Manager Agents for HP Integrity servers2. Install HP System Management Homepage3. Install HP Insight Management A

Strona 42

Uninstall HIFILThis option is displayed only when HP Management Base is installed on the system.To remove the HIFIL product, including HP Management B

Strona 44 - Before Running the Installer

A Configuring and Using a Serial ConsoleBefore the Linux operating system (OS) is booted, all console interaction occurs through EFI. Tomodify the def

Strona 45 - Running the Installer

HP SAS Integrated Raid (IR) Configuration Utility May Cause Kernel Panics on RHEL4U7...58Flashing HP PCIe 2-port 1000Base-T adapter (AD337A)

Strona 46

IMPORTANT: Exactly one UART must be selected in the EFI Console-In/Out tables for a serialconsole to work. The UART selected in this table is ttyS0.Th

Strona 47

B HP Support Pack DependenciesSome software products contained in the HP Support Pack have dependencies or prerequisitesthat may or may not, already b

Strona 48

glibc opensslopen64-4.2.1-xxx.ia64.rpm need below packages: gcc glibc info perlRHEL5The following list provides information about software contained

Strona 49 - Configuring a Serial Console

glibc libstdc++ libunwindhp.com-npartition-cmds-1.03.00-xxx.sles10.ia64.rpm need below packages: glibc libgcc libstdc++ libunwindhp.com-parmgr-2.02.0

Strona 51 - RHEL4 51

C Known IssuesThis appendix contains known issues with the HP Insight Foundation Suite for Integrity withLinux product, which undergoes rigorous testi

Strona 52

with the following line:auth required pam_succeed_if.so quiet_success user ingroup sfcb3. Restart SFCB by entering the following:# /etc/ini

Strona 53 - SLES11 53

ELILO boot: Uncompressing Linux... doneLoading file HP-initrd-2.6.18-92.el5xen.img...doneThis is the result of the MPT Fusion driver rebuilding the in

Strona 54

image=vmlinuz-2.6.18-92.el5xen vmm=xen.gz-2.6.18-92.el5 label=HP #Corresponds to kernel 2.6.18-92.el5xen initrd=HP-in

Strona 55 - C Known Issues

D Supported Products MatrixThis appendix lists the adapters that are supported by the HP Insight Foundation Suite forIntegrity with Linux in each of t

Strona 57

Table D-1 Supported Products Matrix (continued)SLES SupportRHEL SupportDescriptionPartNumber1110 SP210 SP1105U154U64U44U34U14LANXXXX4-port GbE Mezz447

Strona 58 - 58 Known Issues

Table D-1 Supported Products Matrix (continued)SLES SupportRHEL SupportDescriptionPartNumber1110 SP210 SP1105U154U64U44U34U14XXXXEmbedded I/O forBL860

Strona 59 - D Supported Products Matrix

Table D-1 Supported Products Matrix (continued)SLES SupportRHEL SupportDescriptionPartNumber1110 SP210 SP1105U154U64U44U34U14XXXXHP PCIe SmartArray E5

Strona 60

Table D-1 Supported Products Matrix (continued)SLES SupportRHEL SupportDescriptionPartNumber1110 SP210 SP1105U154U64U44U34U14XXXXHP PCI-X 2p1000BT, 2p

Strona 61

Table D-1 Supported Products Matrix (continued)SLES SupportRHEL SupportDescriptionPartNumber1110 SP210 SP1105U154U64U44U34U14XXXXEmbedded I/O forBL860

Strona 63

*5992-3193*Printed in the US

Strona 64

About This DocumentThis document describes how to use the HP Insight Foundation Suite for Integrity with Linux(HIFIL) V2.6 product.• The HP Smart Setu

Strona 65

[ERRORNAME]The name of an error, usually returned in the errno variable.KeyThe name of a keyboard key. Return and Enter both refer to the same key.Ter

Strona 66 - *5992-3193*

Publication DateEditionNumberSupported VersionsSupported OSManufacturing PartNumberApril 20082.3RHEL4U4 and later, and RHEL5and RHEL5U1SLES9SP3, and S

Komentarze do niniejszej Instrukcji

Brak uwag