References
180
HP Retail Integrated Barcode Scanner
USB-COM Parameters
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and the
beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in
10ms increments. A setting of zero specifies no delay.
To set the delay:
1. Determine the desired setting in mi
lliseconds.
2. Divide the desired setting by 10 (setting is in
10ms increments). Pad the result with
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Go to page 14 and scan the barcode: SELECT
INTERCHARACTER DELAY SET-
TING.
5. Scan the appropriate two digits from the
keypad in Appendix D, Keypad, that repre-
sent the duration which was determined in the
steps above. You will hear a two-beep
indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit.
This completes the procedure. See Table 25 for some examples of how to set this feature.
Table 25. Intercharacter Delay Setting Examples
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP ACTION EXAMPLES
1 Desired Setting
50ms 150ms 600ms 850ms
2
Divide by 10 (pad with leading
z
eroes to yield two-digits)
05 15 60 85
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT INTERCHARACTER DELAY SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘5’ ‘5’ and ‘0’ ‘6’ and ‘0’ ‘8’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE
Komentarze do niniejszej Instrukcji