6-30 Compaq Integrated Smart Array Controller User Guide
Compaq Confidential Need to Know Required
Writer: CDresden Project: Compaq Integrated Smart Array Controller User Guide Comments:
Part Number: 153236-001 File Name: g-ch6 Compaq Array Configuration Utility.doc Last Saved On: 8/27/99 11:25 AM
3. Create a new logical drive to use the extra space on the expanded array.
For this example, assume a configuration similar to the previous
example, except that the fourth 9.1-GB drive is added later and Array B
does not have a spare. Expand Array B to include the fourth drive. In the
following figure, a single 9.1-GB drive is shown as unassigned in the
main configuration screen.
Figure 6-24. Logical Configuration View screen
To expand the capacity of Array B and create logical drive 2:
1. Select Array B.
2. Select the Expand button.
3. Select the unassigned 9.1-GB drive.
4. Select the Assign Drives to Array button.