Power-on self-t
est diagnostics
The mp x100/100
b performs a series of tests as part of its power-on procedure. The POST diagnostic
program perfor
ms the following tests:
• Memory
• FLASH validation
• PCI device dis
covery
• Management Ethernet por t
Heartbeat LED blink patterns
The Heartbeat LED indicates the operational status of the mpx100/100b. When the POST completes with
no errors, the Heartbeat LED blinks at a steady rate of once per second. When the mpx100/100b is in
maintenance mode, the Heartbeat LED illuminates continuously. The blink patterns that indicate critical
errors are described in the following sections. In addition to producing a Heartbeat error blink pattern, a
critical error also illuminates the System Fault LED.
The Heartbeat LED shows an error blink p attern for the following conditions:
• 1 blink—Normal operation
• 2blinks—Notused
• 3 blinks—System error
• 4 blinks—Management por t IP address conflict
• 5 blinks—Over temperature
Normal heartbeat blink pattern
Ablinkpat
tern of one second ON followed by one second OFF indicates that the mpx100/100b
is operating normally (see Figure 72).
Figure 72 N ormal heartbeat b link pattern
System error blink pattern
A system error is indicated with a three-blink pattern (see Figure 73).
Figure 73
System error blink pattern
Management port IP address conflict blink pattern
An IP address conflict on the management Ethernet port is ind icated with a four-blink pattern (see
Figure 74).
174