Utilities 27
Options Description
-u
Show unavailable fields. Only valid with
-fj
or
-fx
.
-U
Show unavailable fields and details why. Only valid with
-fj
or
-fx
.
-F<field>
Print the value for a single field (For field names, see the next option). Requires that a
device be specified. Multiple
-F
options may be specified.
-l
List the fields that can be individually accessed with
-F
.
CAUTION: Output Change
Starting with version 3.0.0 and later, the standard formatting of fio-status output has
changed. This will affect any custom management tools that used the output of this utility.
Basic information: If no options are used, fio-status reports the following basic information:
Number and type of devices installed in the system
IO Accelerator version
Adapter information:
Adapter type
Product number
External power status
PCIe power limit threshold (if available)
Connected IO Accelerator devices
Block device information:
Attach status
Product name
Product number
Serial number
PCIe address and slot
Firmware version
Size of the device, out of total capacity
Internal temperature (average and maximum, since IO Accelerator load) in degrees Centigrade
Health status: healthy, nearing wearout, write-reduced or read-only
Reserve capacity (percentage)
Warning capacity threshold (percentage)
Data volume information: If the -d option is used, the following data volume information is reported in
addition to the basic information:
Physical bytes written
Physical bytes read
All information: If the -a option is used, all information is printed, which includes the following information
in addition to basic and data volume information.
Adapter information: