Fan 3: 14000 RPM (78%)
Fan 4: 14000 RPM (78%)
Fan 5: 14000 RPM (78%)
Fan 6: 14000 RPM (78%)
Fan 7: 14000 RPM (78%)
Fan 8: 14000 RPM (78%)
Fan 9: 14000 RPM (78%)
Fan 10: 14000 RPM (78%)
Fan 11: 14000 RPM (78%)
Fan 12: 14000 RPM (78%)
Fan 13: 14000 RPM (78%)
Fan 14: 14000 RPM (78%)
Fan 15: 14000 RPM (78%)
SHOW ENCLOSURE TEMP
Command:
SHOW ENCLOSURE TEMP
Description:
Displays:
Locale
Status (OK, warm, degraded, or failed)
Temperature in degrees Fahrenheit
Temperature in degrees Celsius for all temperature sensors
NOTE: Interconnect modules and GPSMs only display temperature status.
Access level/Bay level:
All
Bay specific
Restrictions:
There is no temperature display provided for Interconnect Modules or GPSMs. Those
modules will show only Status and Limits.
Example:
Locale Bay # Temp Status Temp Caution Critical
---------------------- ----- ----------- -------- ------- --------
Enclosure N/A 26C/ 78F --- ---
Onboard Administrator 1 OK 35C/ 95F 75C 80C
Blade Bay 3 Unknown 25C/ 77F 38C 43C
Blade Bay 4 Unknown 26C/ 78F 45C 60C
Blade Bay 8 Unknown 26C/ 78F 35C 38C
Interconnect Module 1 OK ---- --- ---
Interconnect Module 2 OK ---- --- ---
XFM 3 Unknown 26C/ 78F 35C 38C
GPSM 1 OK ---- --- ---
SHOW ENCLOSURE TEMP 83