service reference guide
HP Compaq dc5750 Business PC
1st Edition
x
This document provides information on the removal and replacement of all
parts as well as information on troubleshooting, Desktop Management, setup
utilities, SATA drives, safety, routine care, connector pin assignments, POST
error messages, and diagnostic indicator lights.
Document Part Number 437963-001
Przeglądanie stron 0
1 2 3 4 5 6 ... 213 214

Podsumowanie treści

Strona 1 - 1st Edition

service reference guideHP Compaq dc5750 Business PC 1st EditionxThis document provides information on the removal and replacement of all parts as well

Strona 2

1–2 437963-001 Service Reference Guide, dc5750Installing the Operating System1.2 Transferring Files and SettingsUse the Microsoft Windows XP Files an

Strona 3 - Service Reference Guide

6–32 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.16 Power SupplyÅWARNING: Voltage is always

Strona 4 - First Edition (November 2006)

Service Reference Guide, dc5750 437963-001 6–33Removal and Replacement Procedures— Microtower (MT) Chassis6.17 System Board 1. Prepare the computer fo

Strona 5 - Contents

6–34 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.18 BatteryThe battery that comes with your

Strona 6

Service Reference Guide, dc5750 437963-001 6–35Removal and Replacement Procedures— Microtower (MT) Chassis6.18.1 Type 1 Battery Holder1. Lift the batt

Strona 7

6–36 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.18.2 Type 2 Battery Holder1. To release th

Strona 8

Service Reference Guide, dc5750 437963-001 6–37Removal and Replacement Procedures— Microtower (MT) Chassis6.18.3 Type 3 Battery Holder1. Pull back on

Strona 9

6–38 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis

Strona 10

Service Reference Guide, dc5750 437963-001 7–17Removal and Replacement Procedures—Small Form Factor (SFF) ChassisAdherence to the procedures and preca

Strona 11 - 2.1 Power-On Self-Test (POST)

7–2 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.2 Extern al S e c u rity D evices7.

Strona 12 - 2.2 Computer Setup Utilities

Service Reference Guide, dc5750 437963-001 7–3Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.3 A cces s Panel 1. Prepare the co

Strona 13

Service Reference Guide, dc5750 437963-001 2–12Setup Utilities and Diagnostics FeaturesSetup Utilities (F10) and diagnostic features provide informati

Strona 14 - 2.2.2 Computer Setup Menu

7–4 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.4 Fron t B ezel1. Prepare the compu

Strona 15

Service Reference Guide, dc5750 437963-001 7–5Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.5 Front D rive B ezels1. Prepare t

Strona 16

7–6 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.6 Cable Management The Small Form F

Strona 17

Service Reference Guide, dc5750 437963-001 7–7Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.6.1 Cable ConnectionsSystem board c

Strona 18

7–8 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.7 Dr ivesA Torx T-15 screwdriver is

Strona 19

Service Reference Guide, dc5750 437963-001 7–9Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.7.2 O pti cal Drive ÄCAUTION: All

Strona 20

7–10 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis6. Remove the two M3 metric guide sc

Strona 21

Service Reference Guide, dc5750 437963-001 7–11Removal and Replacement Procedures— Small Form Factor (SFF) Chassis8. Connect the power 1 cable and dat

Strona 22

7–12 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.7.3 Exte rn al 3. 5- in c h D ri

Strona 23

Service Reference Guide, dc5750 437963-001 7–13Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7. Tilt the left side of the drive d

Strona 24 - 2.3 HP Insight Diagnostics

2–2 437963-001 Service Reference Guide, dc5750Setup Utilities and Diagnostics Features2.2 Computer Setup UtilitiesUse Computer Setup Utilities (F10)

Strona 25 - 2.3.2 Survey Tab

7–14 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.7.4 H ard Drive A Torx T-15 screw

Strona 26 - 2.3.3 Test Tab

Service Reference Guide, dc5750 437963-001 7–15Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7. Press down on the lever to the le

Strona 27 - 2.3.6 Help Tab

7–16 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis✎If the system has only one SATA har

Strona 28 - Enter key

Service Reference Guide, dc5750 437963-001 7–17Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.8 Mem or y ÄCAUTION: The memory mo

Strona 29 - Desktop Management

7–18 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis✎A memory module can be installed in

Strona 30 - 3.1.1 HP OpenView Agent

Service Reference Guide, dc5750 437963-001 7–19Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.9 Expansion Card 7.9.1 Expansion

Strona 31

7–20 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis6. If you are removing an existing P

Strona 32 - 3.3.3 HP Client Manager

Service Reference Guide, dc5750 437963-001 7–21Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.10 Power Supply ÅWARNING: Voltage

Strona 33 - 3.3.5 HP Client Premium Suite

7–22 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.11 Fan Shroud 1. Prepare the compu

Strona 34

Service Reference Guide, dc5750 437963-001 7–23Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.12 Front I/O Device 1. Prepare the

Strona 35 - 3.4 ROM Flash

Service Reference Guide, dc5750 437963-001 2–3Setup Utilities and Diagnostics Features2.2.1 Using Computer Setup (F10) Utilities Computer Setup can b

Strona 36 - Software Manager at

7–24 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.13 Chassis Fan1. Prepare the compu

Strona 37 - 3.4.2 HPQFlash

Service Reference Guide, dc5750 437963-001 7–25Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.14 Power Swit c h Assemb ly 1. P

Strona 38 - 3.4.4 Replicating the Setup

7–26 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7. Squeeze the switch holder retaini

Strona 39 - Copying to Multiple Computers

Service Reference Guide, dc5750 437963-001 7–27Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.15 Spea ke r 1. Prepare the comput

Strona 40 - Creating a Bootable Device

7–28 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.16 Heatsi nk 1. Prepare the comput

Strona 41

Service Reference Guide, dc5750 437963-001 7–29Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.17 P rocessor 1. Prepare the compu

Strona 42 - 3.4.5 Dual-State Power Button

7–30 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) ChassisÄCAUTION: Heatsink retaining screws

Strona 43 - 3.4.7 Industry Standards

Service Reference Guide, dc5750 437963-001 7–31Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.18 Sys tem B oard 1. Prepare the

Strona 44

7–32 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.19 Bat t er yThe battery that come

Strona 45

Service Reference Guide, dc5750 437963-001 7–33Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.19.1 Type 1 Battery Holder1. Lift

Strona 46 - 3.5.1 Password Security

2–4 437963-001 Service Reference Guide, dc5750Setup Utilities and Diagnostics Features2.2.2 Computer Setup MenuHeading Option DescriptionFile System I

Strona 47 - Entering a Setup Password

7–34 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.19.2 Typ e 2 Ba t te ry H ol der1

Strona 48

Service Reference Guide, dc5750 437963-001 7–35Removal and Replacement Procedures— Small Form Factor (SFF) Chassis7.19.3 Type 3 B a ttery Ho lde r1

Strona 49 - 3.5.4 DriveLock

7–36 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Small Form Factor (SFF) Chassis

Strona 50 - DriveLock Applications

Service Reference Guide, dc5750 437963-001 A–1AConnector Pin AssignmentsThis appendix contains the pin assignments for many computer and workstation c

Strona 51 - 3.5.5 Smart Cover Sensor

A–2 437963-001 Service Reference Guide, dc5750Connector Pin AssignmentsEthernet RJ-45Connector and Icon Pin Signal1234(+) Transmit Data(-) Transmit Da

Strona 52 - 3.5.6 Cable Lock Provision

Service Reference Guide, dc5750 437963-001 A–3Connector Pin AssignmentsSerial Interface, Powered and Non-PoweredConnector and Icon Pin Signal123Carrie

Strona 53 - 3.6.3 Thermal Sensor

A–4 437963-001 Service Reference Guide, dc5750Connector Pin AssignmentsLine-Out AudioConnector and Icon (1/8” miniphone) Pin Signal1 (Tip) Audio_Out_L

Strona 54

Service Reference Guide, dc5750 437963-001 A–5Connector Pin AssignmentsATA/ATAPI (IDE) Standard Drive CableConnectorPin Signal Pin Signal Pin Signal12

Strona 55 - Features

A–6 437963-001 Service Reference Guide, dc5750Connector Pin Assignments24-Pin MicroFit Power (USDT, SFF, and ST models)ConnectorPin Signal Pin Signal

Strona 56 - 4.2 SATA Hard Drive Cables

Service Reference Guide, dc5750 437963-001 A–7Connector Pin Assignments SATA Data and Power Drive ConnectorPin Signal Pin Signal Pin Signal Pin Signal

Strona 57 - 4.5 Hard Drive Capacities

Service Reference Guide, dc5750 437963-001 2–5Setup Utilities and Diagnostics FeaturesStorage Device ConfigurationLists all installed BIOS-controlled

Strona 58

A–8 437963-001 Service Reference Guide, dc5750Connector Pin AssignmentsPCI Express x1, x4, x8, and x16 PCI Express ConnectorPin APin Signal Pin Signal

Strona 59 - Disassembly Preparation

Service Reference Guide, dc5750 437963-001 A–9Connector Pin AssignmentsPin BPin Signal Pin Signal Pin Signal Pin Signal Pin Signal12345+12V+12VRSVDGND

Strona 60 - 5.1.2 Microtower (MT)

A–10 437963-001 Service Reference Guide, dc5750Connector Pin AssignmentsDVI ConnectorConnector and IconPin Signal Pin Signal1234T.M.D.S. Data2-T.M.D.S

Strona 61 - 5.2.1 Generating Static

Service Reference Guide, dc5750 437963-001 B–1BPower Cord Set RequirementsThe power supplies on some computers have external power switches. The volta

Strona 62 - 5.2.4 Grounding the Work Area

B–2 437963-001 Service Reference Guide, dc5750Power Cord Set RequirementsCountry-Specific RequirementsAdditional requirements specific to a country ar

Strona 63 - 5.4 Routine Care

Service Reference Guide, dc5750 437963-001 C–1CPOST Error MessagesPOST Error MessagesAn error message results if the Power-On Self-Test (POST) encount

Strona 64 - 5.4.3 Cleaning the Keyboard

C–2 437963-001 Service Reference Guide, dc5750POST Error Messages162-System Options Not SetConfiguration incorrect.RTC (real-time clock) battery may n

Strona 65 - 5.5 Service Considerations

Service Reference Guide, dc5750 437963-001 C–3POST Error Messages219 -EC C M emo r y Module Detected. ECC Modules not supported on this platformRecen

Strona 66 - 5.5.5 Hard Drives

C–4 437963-001 Service Reference Guide, dc5750POST Error Messages511-CPU, CPUA, or CPUB Fan not detectedCPU fan is not connected or may have malfuncti

Strona 67

Service Reference Guide, dc5750 437963-001 C–5POST Error Messages918-Front USB Not ConnectedFront USB harness has been detached or unseated from syste

Strona 68

2–6 437963-001 Service Reference Guide, dc5750Setup Utilities and Diagnostics FeaturesStorage (continued)Device Configuration (continued)Multisector T

Strona 69 - Microtower (MT) Chassis

C–6 437963-001 Service Reference Guide, dc5750POST Error Messages1720 -S M A R T H a rd Drive Detects Imminent FailureHard drive is about to fail. (

Strona 70 - 6.2 External Security Devices

Service Reference Guide, dc5750 437963-001 C–7POST Error MessagesNetwork Server Mode Active and No Keyboard AttachedKeyboard failure while Network Ser

Strona 71 - 6.2.2 Installing a Padlock

C–8 437963-001 Service Reference Guide, dc5750POST Error MessagesPOST Diagnostic Front Panel LEDs and Audible CodesThis section covers the front panel

Strona 72 - 6.3 Access Panel

Service Reference Guide, dc5750 437963-001 C–9POST Error MessagesRed Power LED flashes three times, once every second, followed by a two second pause.

Strona 73 - 6.4 Front Bezel

C–10 437963-001 Service Reference Guide, dc5750POST Error MessagesRed Power LED flashes six times, once every second, followed by a two second pause.

Strona 74 - To reinstall the front bezel:

Service Reference Guide, dc5750 437963-001 C–11POST Error MessagesRed Power LED flashes nine times, once every second, followed by a two second pause.

Strona 75 - 6.5 Front Drive Bezels

C–12 437963-001 Service Reference Guide, dc5750POST Error MessagesSystem does not power on and LEDs are not flashing.None System unable to power on.Pr

Strona 76 - 6.6 Cable Management

Service Reference Guide, dc5750 437963-001 D–1DTroubleshooting Without DiagnosticsPreliminary ChecklistThis section describes some simple, preliminary

Strona 77 - 6.6.1 Cable Connections

D–2 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsSolving Minor ProblemsSolving Minor ProblemsProblem Cause Possible So

Strona 78 - 6.7 Memory

Service Reference Guide, dc5750 437963-001 D–3Troubleshooting Without DiagnosticsPoor performance is experienced.Processor is hot. 1. Ensure airflow t

Strona 79 - 6.8 Expansion Cards

Service Reference Guide, dc5750 437963-001 2–7Setup Utilities and Diagnostics FeaturesStorage (continued)Storage Options (continued)SATA EmulationAllo

Strona 80

D–4 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsComputer powered off automatically and the Power LED flashes Red two

Strona 81

Service Reference Guide, dc5750 437963-001 D–5Troubleshooting Without DiagnosticsSolving Power Supply ProblemsSolving Power Supply ProblemsProblem Cau

Strona 82

D–6 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsPower LED flashes Red, four times, once every second, followed by a t

Strona 83 - 6.9 Drives

Service Reference Guide, dc5750 437963-001 D–7Troubleshooting Without DiagnosticsSolving Diskette ProblemsSolving Diskette ProblemsProblem Cause Solut

Strona 84

D–8 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsCannot format diskette.(continued)Legacy diskette writes are disabled

Strona 85 - Releasing the Drives

Service Reference Guide, dc5750 437963-001 D–9Troubleshooting Without DiagnosticsSolving Hard Drive ProblemsSolving Hard Drive ProblemsProblem Cause S

Strona 86

D–10 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsNonsystem disk/NTLDR missing message(continued)System is trying to s

Strona 87

Service Reference Guide, dc5750 437963-001 D–11Troubleshooting Without DiagnosticsSolving Media Card Reader ProblemsComputer will not boot from hard d

Strona 88

D–12 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsUnable to access data on the media card after inserting it into a sl

Strona 89

Service Reference Guide, dc5750 437963-001 D–13Troubleshooting Without DiagnosticsSolving Display ProblemsSolving Display ProblemsProblem Cause Soluti

Strona 90

2–8 437963-001 Service Reference Guide, dc5750Setup Utilities and Diagnostics FeaturesStorage (continued)Boot Order Allows you to:• Specify the order

Strona 91

D–14 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsBlank screen (no video).(continued)Monitor settings in the computer

Strona 92

Service Reference Guide, dc5750 437963-001 D–15Troubleshooting Without DiagnosticsBlank screen and the power LED flashes Red seven times, once every s

Strona 93 - 6.10 Chassis Fan

D–16 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsImage is not centered. Position may need adjustment.Press the Menu b

Strona 94 - 6.11 Front Shroud

Service Reference Guide, dc5750 437963-001 D–17Troubleshooting Without DiagnosticsSolving Audio ProblemsCertain typed symbols do not appear correct.Th

Strona 95

D–18 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsSound does not come out of the speaker or headphones.(continued)Audi

Strona 96 - 6.13 Heatsink

Service Reference Guide, dc5750 437963-001 D–19Troubleshooting Without DiagnosticsSolving Printer ProblemsSound does not come out of the speaker or he

Strona 97 - 6.14 Processor

D–20 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsSolving Keyboard and Mouse ProblemsPrinter may have failed. Run prin

Strona 98

Service Reference Guide, dc5750 437963-001 D–21Troubleshooting Without DiagnosticsComputer is in standby mode.Press the power button to resume from st

Strona 99 - 6.15 Speaker

D–22 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsComputer is in standby mode.Press the power button to resume from st

Strona 100 - 6.16 Power Supply

Service Reference Guide, dc5750 437963-001 D–23Troubleshooting Without DiagnosticsSolving Hardware Installation ProblemsYou may need to reconfigure th

Strona 101 - 6.17 System Board

Service Reference Guide, dc5750 437963-001 2–9Setup Utilities and Diagnostics FeaturesSecurity (continued)Embedded Security (This menu only appears af

Strona 102 - 6.18 Battery

D–24 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsComputer will not start. Wrong memory modules were used in the upgra

Strona 103 - 6.18.1 Type 1 Battery Holder

Service Reference Guide, dc5750 437963-001 D–25Troubleshooting Without DiagnosticsSolving Network ProblemsThese guidelines do not discuss the process

Strona 104 - 6.18.2 Type 2 Battery Holder

D–26 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsDiagnostics reports a failure.The cable is not securely connected.En

Strona 105 - 6.18.3 Type 3 Battery Holder

Service Reference Guide, dc5750 437963-001 D–27Troubleshooting Without DiagnosticsNetwork controller stops working without apparent cause.(continued)T

Strona 106

D–28 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsSolving Memory ProblemsÄCAUTION: Power may still be supplied to the

Strona 107

Service Reference Guide, dc5750 437963-001 D–29Troubleshooting Without DiagnosticsSolving Processor Problems.Solving Processor ProblemsProblem Cause S

Strona 108 - 7.2.1 Cable Lock

D–30 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsSolving CD-ROM and DVD ProblemsSolving CD-ROM and DVD ProblemsProble

Strona 109 - 7.3 A cces s Panel

Service Reference Guide, dc5750 437963-001 D–31Troubleshooting Without DiagnosticsMovie will not play in the DVD drive.Movie may be regionalized for a

Strona 110 - 7.4 Fron t B ezel

D–32 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsSolving Drive Key ProblemsSolving Drive Key ProblemsProblem Cause So

Strona 111 - 7.5 Front D rive B ezels

Service Reference Guide, dc5750 437963-001 D–33Troubleshooting Without DiagnosticsSolving Front Panel Component ProblemsSolving Front Panel Component

Strona 113 - 7.6.1 Cable Connections

2–10 437963-001 Service Reference Guide, dc5750Setup Utilities and Diagnostics FeaturesSecurity(continued)Setup Security LevelProvides a method to all

Strona 114 - 7.7 Dr ives

D–34 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsSolving Internet Access ProblemsSolving Internet Access ProblemsProb

Strona 115 - 7.7.2 O pti cal Drive

Service Reference Guide, dc5750 437963-001 D–35Troubleshooting Without DiagnosticsInternet takes too long to download Web sites.Modem is not set up pr

Strona 116

D–36 437963-001 Service Reference Guide, dc5750Troubleshooting Without DiagnosticsSolving Software ProblemsMost software problems occur as a result of

Strona 117

Service Reference Guide, dc5750 437963-001 E–1ESystem Board and Riser Board ReferenceDesignatorsThese reference designators are used on most but not a

Strona 118

E–2 437963-001 Service Reference Guide, dc5750System Board and Riser Board Reference DesignatorsJ68J69J70J71J72Stacked mouse (Top)/keyboard (Bottom) c

Strona 119

Service Reference Guide, dc5750 437963-001 E–3System Board and Riser Board Reference DesignatorsP23P24P25 P26P27Header for front panel audio Header fo

Strona 120 - 7.7.4 H ard Drive

E–4 437963-001 Service Reference Guide, dc5750System Board and Riser Board Reference DesignatorsU6U7U10U11U12Clock chip64 bit BridgeLOM1LOM1 EEPROMLOM

Strona 121

Service Reference Guide, dc5750 437963-001 F–1FMemoryThe dc5750 series computers with AMD-based processors come with double data rate 2 synchronous dy

Strona 122

F–2 437963-001 Service Reference Guide, dc5750MemoryThe system board shown may differ from the one in your product. The system will automatically oper

Strona 123 - 7.8 Mem or y

Service Reference Guide, dc5750 437963-001 Index–1Index4-pin power pin assignments A–624-pin MicroFit power pin assignments A–624-pin power pin assign

Strona 124

Service Reference Guide, dc5750 437963-001 2–11Setup Utilities and Diagnostics FeaturesPower (continued)Thermal Fan idle mode - This bar graph control

Strona 125 - 7.9 Expansion Card

Index–2 437963-001 Service Reference Guide, dc5750IndexDdate and time display problems D–2DDR2 memory F–1deleting password 3–20delimiter characters, t

Strona 126

Service Reference Guide, dc5750 437963-001 Index–3Indexhardware, Proactive Change Notification (PCN) 3–7headphone pin assignments A–3heatsinkMT remova

Strona 127 - 7.10 Power Supply

Index–4 437963-001 Service Reference Guide, dc5750Indexoptical driveMT removal and replacement 6–16SFF removal and replacement 7–9 to 7–11overheating,

Strona 128 - 7.11 Fan Shroud

Service Reference Guide, dc5750 437963-001 Index–5IndexMT padlock 6–3MT PCI expansion card 6–12MT PCI Express expansion card 6–13MT power supply 6–32M

Strona 129 - 7.12 Front I/O Device

Index–6 437963-001 Service Reference Guide, dc5750IndexSmall Form Factor See SFFSmart Cover Locklocking 3–24unlocking 3–24Smart Cover Sensorprotection

Strona 130 - 7.13 Chassis Fan

2–12 437963-001 Service Reference Guide, dc5750Setup Utilities and Diagnostics FeaturesAdvanced*(continued)*For advanced users onlyPower-On Options(co

Strona 131

Service Reference Guide, dc5750 437963-001 2–13Setup Utilities and Diagnostics FeaturesAdvanced*(continued)*For advanced users onlyBus Options* On som

Strona 132

2–14 437963-001 Service Reference Guide, dc5750Setup Utilities and Diagnostics Features2.2.3 Recovering the Configuration SettingsThis method of recov

Strona 133 - 7.15 Spea ke r

Service Reference Guide, dc5750 437963-001 2–15Setup Utilities and Diagnostics Features2.3.1 Accessing HP Insight DiagnosticsYou must boot to the Doc

Strona 134 - 7.16 Heatsi nk

2–16 437963-001 Service Reference Guide, dc5750Setup Utilities and Diagnostics FeaturesSystem—Shows information about the computer model, processor, c

Strona 135 - 7.17 P rocessor

Service Reference Guide, dc5750 437963-001 2–17Setup Utilities and Diagnostics Features2.3.4 Status TabThe Status tab displays the status of the selec

Strona 136

2–18 437963-001 Service Reference Guide, dc5750Setup Utilities and Diagnostics Features2.3.7 Saving and Printing Information in HP Insight Diagnostics

Strona 137 - 7.18 Sys tem B oard

Service Reference Guide, dc5750 437963-001 3–13Desktop ManagementHP Client Management Solutions provides standards-based solutions for managing and co

Strona 138 - 7.19 Bat t er y

Service Reference GuideHP Compaq dc5750 Business PC1st EditionDocument Part Number: 437963-001November 2006

Strona 139 - 7.19.1 Type 1 Battery Holder

3–2 437963-001 Service Reference Guide, dc5750Desktop Management3.1.1 HP OpenView AgentThe Radia Management Agent (RMA) used by both HP OpenView Clie

Strona 140

Service Reference Guide, dc5750 437963-001 3–3Desktop Management3.2 Remote System InstallationRemote System Installation allows you to start and set u

Strona 141

3–4 437963-001 Service Reference Guide, dc5750Desktop ManagementWhen HP Client Management Interface is used in conjunction with system management soft

Strona 142

Service Reference Guide, dc5750 437963-001 3–5Desktop Management HP Knowledgebase—link to expert information Automated SoftPaq collection and delive

Strona 143 - Connector Pin Assignments

3–6 437963-001 Service Reference Guide, dc5750Desktop Management Altiris Migration Suite Altiris Local Recovery ProFor more information about the HP

Strona 144 - Parallel Interface

Service Reference Guide, dc5750 437963-001 3–7Desktop Management3.3.9 Proactive Change NotificationThe Proactive Change Notification program uses the

Strona 145 - Line-In Audio

3–8 437963-001 Service Reference Guide, dc5750Desktop Management✎The computer must be powered on, or turned on through Remote Wakeup, to take advantag

Strona 146 - External Infrared Transceiver

Service Reference Guide, dc5750 437963-001 3–9Desktop Management3.4.2 HPQFlashThe HPQFlash utility is used to locally update or restore the system BIO

Strona 147

3–10 437963-001 Service Reference Guide, dc5750Desktop Management3.4.4 Replicating the SetupThe following procedures give an administrator the ability

Strona 148

Service Reference Guide, dc5750 437963-001 3–11Desktop ManagementCopying to Multiple ComputersÄCAUTION: A setup configuration is model-specific. File

Strona 149

© Copyright 2006 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice. Microsoft, MS-DOS, Win

Strona 150 - PCI Express

3–12 437963-001 Service Reference Guide, dc5750Desktop ManagementCreating a Bootable DeviceSupported USB Flash Media DeviceSupported devices have a pr

Strona 151

Service Reference Guide, dc5750 437963-001 3–13Desktop Management10. At the A:\ prompt, enter FORMAT /S X: where X represents the drive letter noted b

Strona 152 - DVI Connector

3–14 437963-001 Service Reference Guide, dc5750Desktop Management6. Go to Advanced > PCI Devices to disable both the PATA and SATA controllers. Whe

Strona 153 - Power Cord Set Requirements

Service Reference Guide, dc5750 437963-001 3–15Desktop ManagementAfter configuring the power button to function as a standby button, press the power b

Strona 154 - Country-Specific Requirements

3–16 437963-001 Service Reference Guide, dc5750Desktop Managementremovable media boot capability, you can protect valuable data assets. Memory Change

Strona 155 - POST Error Messages

Service Reference Guide, dc5750 437963-001 3–17Desktop ManagementDevice Security Enables/disables serial ports, parallel port, front USB ports, system

Strona 156

3–18 437963-001 Service Reference Guide, dc5750Desktop Management3.5.1 Password SecurityThe power-on password prevents unauthorized use of the compute

Strona 157

Service Reference Guide, dc5750 437963-001 3–19Desktop Management3.5.3 Establishing a Power-On Password Using Computer SetupEstablishing a power-on pa

Strona 158

3–20 437963-001 Service Reference Guide, dc5750Desktop ManagementChanging a Power-On or Setup PasswordIf the system is equipped with an embedded secur

Strona 159

Service Reference Guide, dc5750 437963-001 3–21Desktop ManagementNational Keyboard Delimiter CharactersEach keyboard is designed to meet country-speci

Strona 160

Sercice Reference Guide, dc5750 437963-001 iiiContents1 Installing the Operating System1.1 Installing or Upgrading Device Drivers . . . . . . . . . .

Strona 161

3–22 437963-001 Service Reference Guide, dc5750Desktop ManagementUsing DriveLockWhen one or more hard drives that support the ATA Security command set

Strona 162

Service Reference Guide, dc5750 437963-001 3–23Desktop Management3.5.5 Smart Cover SensorCover Removal Sensor, available on some models, is a combinat

Strona 163

3–24 437963-001 Service Reference Guide, dc5750Desktop ManagementLocking the Smart Cover LockTo activate and lock the Smart Cover Lock, complete the f

Strona 164

Service Reference Guide, dc5750 437963-001 3–25Desktop Management3.5.7 Fingerprint Identification TechnologyEliminating the need to enter user passwor

Strona 165

3–26 437963-001 Service Reference Guide, dc5750Desktop Management

Strona 166

Service Reference Guide, dc5750 437963-001 4–14Serial and Parallel ATA Drive Guidelines andFeatures✎Serial ATA = SATAParallel ATA = PATAHP only suppor

Strona 167 - Preliminary Checklist

4–2 437963-001 Service Reference Guide, dc5750Serial and Parallel ATA Drive Guidelines and Features4.2 SATA Hard Drive Cables4.2.1 SATA Data CableAlw

Strona 168 - Solving Minor Problems

Service Reference Guide, dc5750 437963-001 4–3Serial and Parallel ATA Drive Guidelines and Features4.3 PATA Device InformationNo PATA drives are suppo

Strona 169

4–4 437963-001 Service Reference Guide, dc5750Serial and Parallel ATA Drive Guidelines and Features

Strona 170

Service Reference Guide, dc5750 437963-001 5–15Identifying the Chassis, Routine Care, andDisassembly PreparationThis chapter provides general service

Strona 171 - Solving Power Supply Problems

iv 437963-001 Service Reference Guide, dc5750Contents3.4.1 Remote ROM Flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 172

5–2 437963-001 Service Reference Guide, dc5750Identifying the Chassis, Routine Care, and Disassembly Preparation5.1.2 Microtower (MT)

Strona 173 - Solving Diskette Problems

Service Reference Guide, dc5750 437963-001 5–3Identifying the Chassis, Routine Care, and Disassembly Preparation5.2 Electrostatic Discharge Informatio

Strona 174

5–4 437963-001 Service Reference Guide, dc5750Identifying the Chassis, Routine Care, and Disassembly Preparation5.2.3 Personal Grounding Methods and E

Strona 175 - Solving Hard Drive Problems

Service Reference Guide, dc5750 437963-001 5–5Identifying the Chassis, Routine Care, and Disassembly Preparation Static awareness labels Wrist strap

Strona 176

5–6 437963-001 Service Reference Guide, dc5750Identifying the Chassis, Routine Care, and Disassembly Preparation2. Never immerse any parts in water or

Strona 177

Service Reference Guide, dc5750 437963-001 5–7Identifying the Chassis, Routine Care, and Disassembly Preparation5.4.4 Cleaning the Monitor Wipe the m

Strona 178 - Never remove the card when

5–8 437963-001 Service Reference Guide, dc5750Identifying the Chassis, Routine Care, and Disassembly Preparation5.5.3 ScrewsThe screws used in the com

Strona 179 - Solving Display Problems

Service Reference Guide, dc5750 437963-001 5–9Identifying the Chassis, Routine Care, and Disassembly Preparation5.5.6 Lithium Coin Cell BatteryThe bat

Strona 180

5–10 437963-001 Service Reference Guide, dc5750Identifying the Chassis, Routine Care, and Disassembly Preparation

Strona 181

Service Reference Guide, dc5750 437963-001 6–16Removal and Replacement Procedures—Microtower (MT) ChassisAdherence to the procedures and precautions d

Strona 182 - Ensure the computer power is

Service Reference Guide, dc5750 437963-001 vContents5.5.2 Tools and Software Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 183 - Solving Audio Problems

6–2 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.2 External Security Devices6.2.1 Installin

Strona 184

Service Reference Guide, dc5750 437963-001 6–3Removal and Replacement Procedures— Microtower (MT) Chassis6.2.2 Installing a Padlock A padlock may be u

Strona 185 - Solving Printer Problems

6–4 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.3 Access Panel 1. Prepare the computer for

Strona 186

Service Reference Guide, dc5750 437963-001 6–5Removal and Replacement Procedures— Microtower (MT) Chassis6.4 Front Bezel 1. Prepare the computer for d

Strona 187

6–6 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) ChassisTo reinstall the front bezel:1. Position the

Strona 188

Service Reference Guide, dc5750 437963-001 6–7Removal and Replacement Procedures— Microtower (MT) Chassis6.5 Front Drive Bezels Follow these steps be

Strona 189

6–8 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.6 Cable ManagementAlways follow good cable

Strona 190

Service Reference Guide, dc5750 437963-001 6–9Removal and Replacement Procedures— Microtower (MT) Chassis6.6.1 Cable ConnectionsSystem board connector

Strona 191 - Solving Network Problems

6–10 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.7 MemoryÄCAUTION: The memory module socket

Strona 192

Service Reference Guide, dc5750 437963-001 6–11Removal and Replacement Procedures— Microtower (MT) Chassis6.8 Expansion Cards1. Prepare the computer f

Strona 193

vi 437963-001 Service Reference Guide, dc5750Contents7.7.2 Optical Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 194 - Solving Memory Problems

6–12 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis4. Before installing an expansion card, remo

Strona 195 - Solving Processor Problems

Service Reference Guide, dc5750 437963-001 6–13Removal and Replacement Procedures— Microtower (MT) Chassisc. If removing a PCI Express x16 card, pull

Strona 196

6–14 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis7. If replacing or adding a new expansion ca

Strona 197

Service Reference Guide, dc5750 437963-001 6–15Removal and Replacement Procedures— Microtower (MT) Chassis6.9 DrivesThe computer supports up to five d

Strona 198 - Solving Drive Key Problems

6–16 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.9.2 Removing an External Drive 1. Remove a

Strona 199

Service Reference Guide, dc5750 437963-001 6–17Removal and Replacement Procedures— Microtower (MT) ChassisDisconnecting Diskette Drive Cables Releasin

Strona 200

6–18 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.9.3 Installing an External Drive ÄCAUTION:

Strona 201

Service Reference Guide, dc5750 437963-001 6–19Removal and Replacement Procedures— Microtower (MT) Chassis2. Slide the drive into the drive bay, makin

Strona 202 - Solving Software Problems

6–20 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) ChassisConnecting Diskette Drive Cables4. Install t

Strona 203 - Designators

Service Reference Guide, dc5750 437963-001 6–21Removal and Replacement Procedures— Microtower (MT) Chassis4. Remove the front bezel (Section 6.4).5. D

Strona 204

Service Reference Guide, dc5750 437963-001 1–11Installing the Operating SystemÄCAUTION: Do not add optional hardware or third-party devices to your co

Strona 205

6–22 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis7. Release the drive by pulling the green re

Strona 206

Service Reference Guide, dc5750 437963-001 6–23Removal and Replacement Procedures— Microtower (MT) Chassis10. Slide the drive into the drive bay, maki

Strona 207 - DIMM Sockets

6–24 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis✎If your system only has one SATA hard drive

Strona 208

Service Reference Guide, dc5750 437963-001 6–25Removal and Replacement Procedures— Microtower (MT) Chassis6.10 Chassis Fan 1. Prepare the computer for

Strona 209

6–26 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.11 Front Shroud 1. Prepare the computer fo

Strona 210

Service Reference Guide, dc5750 437963-001 6–27Removal and Replacement Procedures— Microtower (MT) Chassis6.12 Front I/O Panel Housing Assembly 1. Pr

Strona 211

6–28 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) Chassis6.13 Heatsink 1. Prepare the computer for di

Strona 212

Service Reference Guide, dc5750 437963-001 6–29Removal and Replacement Procedures— Microtower (MT) Chassis6.14 Processor 1. Prepare the computer for d

Strona 213

6–30 437963-001 Service Reference Guide, dc5750Removal and Replacement Procedures— Microtower (MT) ChassisÄCAUTION: Heatsink retaining screws should b

Strona 214

Service Reference Guide, dc5750 437963-001 6–31Removal and Replacement Procedures— Microtower (MT) Chassis6.15 Speaker 1. Prepare the computer for dis