HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide April 2005 (First Edition) Part Number 391001-001

Strona 2 - Audience assumptions

10 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Rear panel components Item Description 1* PCI-X expansion slot 1, 64-bit/133-

Strona 3 - Contents

100 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide POST problems flowchart Symptoms: • Server does not complete POST NOTE: The

Strona 4

Troubleshooting 101 Item Refer to 7 • "Hardware problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation

Strona 5

102 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

Strona 6

Troubleshooting 103 OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system • Server does not boot Sm

Strona 7 - Front panel components

104 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item Refer to 8 • "Hardware problems" in the HP ProLiant Servers Trou

Strona 9

106 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Server fault indications flowchart Symptoms: • Server boots, but a fault event

Strona 10 - Rear panel components

Troubleshooting 107 Item Refer to 6 • "Hard drive problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentatio

Strona 11 - Rear panel LEDs and buttons

108 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

Strona 12 - System board components

Troubleshooting 109 POST error messages and beep codes List of messages: Introduction to POST error messages...

Strona 13 - System maintenance switch

Server component identification 11 * Depending on the model of the server, slot 1 or slot 2 will be pre-populated with a storage controller. If t

Strona 15

111 Electrostatic discharge In this section Preventing electrostatic discharge ...

Strona 16

112 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Grounding methods to prevent electrostatic discharge Several methods are used fo

Strona 17

113 Regulatory compliance notices In this section Regulatory compliance identification numbers...

Strona 18 - Internal USB connector

114 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Federal Communications Commission notice Part 15 of the Federal Communications C

Strona 19 - SAS and SATA device numbers

Regulatory compliance notices 115 Class B equipment This equipment has been tested and found to comply with the limits for a Class B digital device

Strona 20

116 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 772

Strona 21 - Fan module locations

Regulatory compliance notices 117 European Union regulatory notice This product complies with the following EU Directives: • Low Voltage Directiv

Strona 22

118 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Japanese notice BSMI notice

Strona 23 - Server operations

Regulatory compliance notices 119 Korean notice A&B Class A equipment Class B equipment Laser compliance This product may be provided with

Strona 24 - Powering down the server

12 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item Description Status 6 10/100/1000 NIC 1 activity Green = Activity exists. Fl

Strona 25 - Server operations 25

120 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • Do not try to open the module enclosure. There are no user-serviceable compon

Strona 26 - Installing the access panel

Regulatory compliance notices 121 Taiwan battery recycling notice The Taiwan EPA requires dry battery manufacturing or importing firms in accordanc

Strona 28

123 Server specifications In this section Environmental specifications ...

Strona 29 - Server setup

124 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Input requirement Specification Rated input voltage 100 VAC to 240 VAC Rated i

Strona 30 - Rack planning resources

125 Technical support In this section Customer self repair...

Strona 31 - Optimum environment

126 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • In Canada, call 1-800-263-5868. • In other locations, refer to the HP websit

Strona 32 - Temperature requirements

127 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ASR Automatic Server Recovery BBWC battery-backed write cac

Strona 33 - Power requirements

128 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide iLO Integrated Lights-Out IML Integrated Management Log IPL initial program lo

Strona 34 - Rack warnings

Acronyms and abbreviations 129 PCI Express peripheral component interconnect express PCI-X peripheral component interconnect extended PDU power

Strona 35 - Server setup 35

Server component identification 13 Item Description 7 Optical device/multi-bay connector 8 Power supply connector 9 Power supply signal connec

Strona 36 - Installing hardware options

130 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide SCSI small computer system interface SDRAM synchronous dynamic RAM SIM Systems

Strona 37 - Server setup 37

Acronyms and abbreviations 131 VHDCI very high density cable interconnect WOL Wake-on LAN

Strona 39 - Registering the server

133 Index A AC power supply 51 access panel 26 additional information 109, 125 ADU (Array Diagnostic Utility) 78 array, configuring 48

Strona 40

134 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide G general diagnosis flowchart 95 grounding methods 112 grounding requirement

Strona 41 - Processor option

Index 135 P PCI riser board 27 phone numbers 125 POST error messages 109 POST problems flowchart 100 power connectors, internal 12 power

Strona 42

136 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide T Taiwan battery recycling notice 121 technical support 125 telephone number

Strona 43

14 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide NMI switch The NMI switch allows administrators to perform a memory dump before p

Strona 44 - Memory options

Server component identification 15 Item LED Description Status 3 DIMM 4B failure Amber = DIMM has failed. Off = DIMM is operating normally. 4

Strona 45 - Single- and dual-rank DIMMs

16 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item LED Description Status 15 System diagnostic Refer to the HP Remote Lights

Strona 46 - Installing DIMMs

Server component identification 17 System LED and color Internal Health LED color Status Processor failure, both sockets (Amber) Red Processor

Strona 47 - Hard drive options

18 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide System LED and color Internal Health LED color Status Power supply signal interl

Strona 48 - Removing a hard drive blank

Server component identification 19 SAS and SATA device numbers Identifying the status of a hard drive When a drive is configured as a part of a

Strona 49

© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties f

Strona 50

20 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide SAS and SATA hard drive LED combinations 1 - Fault/UID LED (amber/blue) 2 -

Strona 51

Server component identification 21 Fan module locations Item Description 1 Power supply zone fan module 2 Processor zone fan module

Strona 53 - Expansion board options

23 Server operations In this section Powering up the server ...

Strona 54 - Expansion board

24 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Status Amber = One fan in this module has failed. Red = Multiple fans in this

Strona 55

Server operations 25 Extending the server from the rack NOTE: If the optional cable management arm option is installed, you can extend the server

Strona 56

26 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide b. Secure the server by tightening the thumbscrews. 6. Reconnect the peripheral

Strona 57

Server operations 27 Removing PCI riser board assembly CAUTION: To prevent damage to the server or expansion boards, power down the server and r

Strona 58

28 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Installing PCI riser board assembly CAUTION: To prevent damage to the server o

Strona 59

29 Server setup In this section Optional installation services...

Strona 60

3 Contents Server component identification 7 Front panel components...

Strona 61 - Server cabling

30 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide – HP ProLiant Essentials (HP SIM and RDP) – VMWare • Integrated hardware and s

Strona 62

Server setup 31 • The Rack Products Documentation CD enables you to view, search, and print documentation for HP and Compaq branded racks and ra

Strona 63 - Configuration tools

32 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide CAUTION: Always use blanking panels to fill empty vertical spaces in the rack.

Strona 64

Server setup 33 • Do not permit optional equipment to impede airflow around the server or to increase the internal rack temperature beyond the m

Strona 65 - HP ROM-Based Setup Utility

34 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide For more information on the hot-plug power supply and calculators to determine se

Strona 66

Server setup 35 • The leveling jacks are extended to the floor. • The full weight of the rack rests on the leveling jacks. • The stabilizing f

Strona 67

36 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • Hardware options • Operating system or application software Installing hardw

Strona 68 - Array Configuration Utility

Server setup 37 WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications c

Strona 69

38 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide * Depending on the model of the server, slot 1 or slot 2 will be pre-populated w

Strona 70 - Management tools

Server setup 39 Installing the operating system To operate properly, the server must have a supported operating system. For the latest informatio

Strona 71 - ROMPaq utility

4 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Installing the server into the rack...

Strona 73 - Erase Utility

41 Hardware options installation In this section Introduction ...

Strona 74 - HP Systems Insight Manager

42 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide CAUTION: To prevent thermal instability and damage to the server, do not separ

Strona 75 - Redundant ROM support

Hardware options installation 43 5. Remove the protective cover from the processor. 6. Align the holes in the processor assembly with the guid

Strona 76

44 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 7. Install the processor assembly and close the processor locking lever and proc

Strona 77 - Diagnostic tools

Hardware options installation 45 NOTE: When configuring the memory sub-system to run in Online Spare mode, only single rank DIMMs can be install

Strona 78 - HP Insight Diagnostics

46 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide In the online spare configuration, the ROM automatically configures the last popu

Strona 79 - Keeping the system current

Hardware options installation 47 6. Install the DIMM. 7. If removed, reinstall the half-length expansion board ("Installing an expansion

Strona 80 - ProLiant Support Packs

48 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Removing a hard drive blank CAUTION: To prevent improper cooling and thermal d

Strona 81 - Care Pack

Hardware options installation 49 Installing a SAS or SATA hot-plug hard drive 1. Power down the server ("Powering down the server" on

Strona 82

Contents 5 HP Systems Insight Manager...74 Redunda

Strona 83 - Battery replacement

50 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide NOTE: Access to the ejector button is intentionally restricted. Push the ejector

Strona 84 - 5. Remove the battery

Hardware options installation 51 Redundant hot-plug AC power supply option CAUTION: To prevent improper cooling and thermal damage, do not ope

Strona 85 - Troubleshooting

52 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide WARNING: To reduce the risk of electric shock or damage to the equipment, do n

Strona 86 - Important safety information

Hardware options installation 53 6. Use the strain relief clip from the server hardware kit to secure the power cord, as illustrated. 7. Route

Strona 87 - Troubleshooting 87

54 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide PCI expansion slot definitions Slot* Board Size Connector Interconnect PCI-

Strona 88 - Warnings and cautions

Hardware options installation 55 5. Remove the expansion board. Installing an expansion board 1. Power down the server ("Powering down t

Strona 89 - Troubleshooting 89

56 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 8. Install the expansion board into the slot until it seats firmly. IMPORTANT:

Strona 90

Hardware options installation 57 5. Remove the expansion slot cover from the slot, if installed ("Installing an expansion board" on pa

Strona 91 - Loose connections

58 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 8. Identify the differences between the two PCI Express riser boards. It

Strona 92 - Diagnostic steps

Hardware options installation 59 a. Install the riser board with the slot for full-length boards onto the assembly. b. Repeat the previous ste

Strona 93 - Troubleshooting 93

6 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Regulatory compliance notices 113 Regulatory compliance identification numbers...

Strona 95 - General diagnosis flowchart

61 Server cabling In this section Cabling overview...

Strona 96

62 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

Strona 97 - Power-on problems flowchart

63 Server software and configuration utilities In this section Configuration tools...

Strona 98

64 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • Testing server hardware using the Insight Diagnostics Utility ("HP Insigh

Strona 99 - Troubleshooting 99

Server software and configuration utilities 65 Configuration Replication Utility ConRep is shipped in the SmartStart Scripting Toolkit and is a p

Strona 100 - POST problems flowchart

66 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • To access RBSU, press the F9 key during power up when prompted in the upper ri

Strona 101 - Troubleshooting 101

Server software and configuration utilities 67 For more information, refer to the HP ROM-Based Setup Utility User Guide on the Documentation CD o

Strona 102

68 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide For more information on online spare memory, refer to the white paper on the HP w

Strona 103 - OS boot problems flowchart

Server software and configuration utilities 69 • Viewing the current logical drive configuration • Deleting a logical drive configuration • Se

Strona 104

7 Server component identification In this section Front panel components...

Strona 105 - Troubleshooting 105

70 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 3. Select Serial Number. The following warning is displayed: WARNING! WARNING!

Strona 106

Server software and configuration utilities 71 Automatic Server Recovery ASR is a feature that causes the system to restart when a catastrophic o

Strona 107 - Troubleshooting 107

72 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide IMPORTANT: This utility supports operating systems that may not be supported by

Strona 108

Server software and configuration utilities 73 To run iLO RBSU: 1. Restart or power up the server. 2. Press the F8 key when prompted during POS

Strona 109 - Other information resources

74 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Run the Erase Utility if you need to erase the system for the following reasons:

Strona 110

Server software and configuration utilities 75 Redundant ROM support The server enables you to upgrade or configure the ROM safely with redundant

Strona 111 - Electrostatic discharge

76 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 4. Install the access panel ("Extending the server from the rack" on p

Strona 112

Server software and configuration utilities 77 • Diagnostics • DOS • Operating environments which do not provide native USB support For more

Strona 113

78 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide This utility supports operating systems that may not be supported by the server.

Strona 114 - Class A equipment

Server software and configuration utilities 79 Integrated Management Log The IML records hundreds of events and stores them in an easy-to-view fo

Strona 115 - Class B equipment

8 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item Description 2 Multi-bay (DVD/CD/Diskette) drive 3 Power on/Standby button a

Strona 116 - Modifications

80 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide If you are installing a SmartStart-supported operating system, use the SmartStart

Strona 117

Server software and configuration utilities 81 Change control and proactive notification HP offers Change Control and Proactive Notification to n

Strona 119 - Laser compliance

83 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the battery that provid

Strona 120 - Battery replacement notice

84 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 5. Remove the battery. IMPORTANT: Replacing the system board battery resets th

Strona 121

85 Troubleshooting In this section Troubleshooting resources...

Strona 122

86 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Server diagnostic steps This section covers the steps to take in order to diagnos

Strona 123 - Server specifications

Troubleshooting 87 This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified

Strona 124 - Specification

88 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide These symbols, on power supplies or systems, indicate that the equipment is sup

Strona 125 - Technical support

Troubleshooting 89 • Do not disable the power cord grounding plug. The grounding plug is an important safety feature. • Plug the power cord into

Strona 126

Server component identification 9 Item Description Status 3 Internal health LED Green = System health is normal. Amber = System is degraded. T

Strona 127 - Acronyms and abbreviations

90 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Preparing the server for diagnosis 1. Be sure the server is in the proper operat

Strona 128

Troubleshooting 91 Symptom information Before troubleshooting a server problem, collect the following information: • What events preceded the fail

Strona 129

92 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • If a fixed cable tray is available for the server, be sure the cords and cable

Strona 130

Troubleshooting 93 Item Refer to 1 "General diagnosis flowchart (on page 95)" 2 "Power-on problems flowchart (on page 97)"

Strona 131 - Wake-on LAN

94 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

Strona 132

Troubleshooting 95 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of

Strona 133

96 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

Strona 134

Troubleshooting 97 Power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber. • The external

Strona 135

98 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item Refer to 5 "Integrated Management Log ("Power-on problems flowcha

Strona 136

Troubleshooting 99

Komentarze do niniejszej Instrukcji