HP Tool Storage 354903-001 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Macierze dyskowe HP Tool Storage 354903-001. HP Tool Storage 354903-001 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Part Number 354903-001

HP StorageWorks Modular Smart Array 500 Generation 2 Storage System Maintenance and Service Guide April 2004 (First Edition) Part Number 354903-001

Strona 2

10 HP MSA 500 G2 Storage System Maintenance and Service Guide CAUTION: In systems that use external data storage, be sure that the server is the

Strona 3 - Contents

Removal and Replacement Procedures 11 To replace the blank, slide the blank into the bay until it locks into place. Hot-Plug SCSI Hard Drive You

Strona 4

12 HP MSA 500 G2 Storage System Maintenance and Service Guide − In RAID 1+0 configurations, any drives that are not mirrored to other removed or f

Strona 5 - Illustrated Parts Catalog

Removal and Replacement Procedures 13 Bezel Blank To remove the component: CAUTION: To prevent improper cooling and thermal damage, do not ope

Strona 6

14 HP MSA 500 G2 Storage System Maintenance and Service Guide To remove the component: CAUTION: To prevent improper cooling and thermal damage,

Strona 7 - Safety Considerations

Removal and Replacement Procedures 15 Battery-Backed Cache Module To remove the component: 1. Determine if the controller configuration supports

Strona 8 - Warnings

16 HP MSA 500 G2 Storage System Maintenance and Service Guide 2. Close the slot latches. 3. Close the controller. Blower To remove the component

Strona 9

Removal and Replacement Procedures 17 − The blower begins operating immediately. − The power supply/blower assembly LED is green. Hot-Plug Powe

Strona 10 - Hard Drive Blank

18 HP MSA 500 G2 Storage System Maintenance and Service Guide 3. Remove the power supply. To replace the power supply: 1. Lift the locking latch

Strona 11 - Hot-Plug SCSI Hard Drive

Removal and Replacement Procedures 19 3. Remove the module. To replace the component, reverse the removal procedure. If you are replacing a faile

Strona 12

© Copyright 2004 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties f

Strona 13 - Bezel Blank

20 HP MSA 500 G2 Storage System Maintenance and Service Guide Interconnect Blank To remove the component: CAUTION: To prevent improper cooling a

Strona 14

Removal and Replacement Procedures 21 3. Remove the power button/LED assembly. To replace the component, slide the power button/LED assembly int

Strona 15 - Battery-Backed Cache Module

22 HP MSA 500 G2 Storage System Maintenance and Service Guide 8. Remove the interconnect blanks ("Interconnect Blank" on page 20). 9. R

Strona 16

23 Diagnostic Tools In This Section Server Utilities...

Strona 17 - Hot-Plug Power Supply

24 HP MSA 500 G2 Storage System Maintenance and Service Guide Management Agents Management Agents provide the information to enable fault, perform

Strona 18

Diagnostic Tools 25 message seeking to initiate Controller Firmware Auto Cloning. Smart Components for ROM Flash To update the firmware on the

Strona 19

26 HP MSA 500 G2 Storage System Maintenance and Service Guide If 60 seconds elapse with no user input, one of the following actions occurs: • In a

Strona 20 - Power Button/LED Assembly

Diagnostic Tools 27 • Runs as a local application or remote service • Supports online array capacity expansion, logical drive extension, assignmen

Strona 21

28 HP MSA 500 G2 Storage System Maintenance and Service Guide NetWare Online Array Configuration Utility (CPQONLIN) The NetWare Online Array Config

Strona 22

29 Component Identification In This Section Front Panel Components ...

Strona 23 - Diagnostic Tools

3 Front Panel Components...

Strona 24 - ROM Functions and Utilities

30 HP MSA 500 G2 Storage System Maintenance and Service Guide Item Description 4 Controller display 5 Power On/Standby button 6 Enclosure LEDs 7

Strona 25 - Recovery ROM

Component Identification 31 Rear Panel Components Item Description 1 Interconnect blanks (required for proper airflow) 2 Power supply/blower as

Strona 26 - Array Configuration Utility

32 HP MSA 500 G2 Storage System Maintenance and Service Guide Power Supply/Blower Assembly LEDs The power supply/blower assembly LEDs have two fun

Strona 27 - Array Diagnostic Utility

Component Identification 33 − Blowers − Drive presence • Detects and reports component changes in the enclosure (identifies hot-plug addition and

Strona 28 - (CPQONLIN)

34 HP MSA 500 G2 Storage System Maintenance and Service Guide 2-Port Shared Storage Module LEDs Item LED Description Status 1 Power Flashing

Strona 29 - Component Identification

Component Identification 35 4-Port Shared Storage Module Components Item Description Bus 1 SCSI port connector A1 A 2 SCSI port connector A2

Strona 30 - Enclosure LEDs

36 HP MSA 500 G2 Storage System Maintenance and Service Guide 4-Port Shared Storage Module LEDs Item LED Description Status 1 Power Flashing

Strona 31 - Rear Panel Components

Component Identification 37 Controller Display Each controller LCD provides informational and error messages. Item Description 1 Display 2 Left b

Strona 32

38 HP MSA 500 G2 Storage System Maintenance and Service Guide Controller LEDs Item LED Description Status 0-2 Busy status Green = Controller

Strona 33 - Component Identification 33

Component Identification 39 Item LED Description Status 11 Logical I/O activity Green = System is currently processing logical requests from the

Strona 34

4 HP MSA 500 G2 Storage System Maintenance and Service Guide Rear Panel Components...

Strona 35 - Component Identification 35

40 HP MSA 500 G2 Storage System Maintenance and Service Guide NOTE: The data protection and the time limit also apply if a power outage occurs. Wh

Strona 36 - Controller Components

Component Identification 41 Bay SCSI ID Bus Port 5 4 0 6 5 0 7 8 0 8 0 1 9 1 1 10 2 1 11 3 1 12 4 1 13 5 1 14 8 1 Hot-Plug SCSI Hard D

Strona 37 - Controller Display

42 HP MSA 500 G2 Storage System Maintenance and Service Guide Off Off On The drive has failed and has been placed offline. You may replace

Strona 38 - Controller LEDs

Component Identification 43 Activity LED (1) Online LED (2) Fault LED (3) Interpretation Off Off Off Either (1) the drive is not configured as p

Strona 40 - SCSI IDs

45 Depth 52.1 cm (20.5 in) Width 48.3 cm (19.0 in) Specifications In This Section Environmental Specifications...

Strona 41 - Component Identification 41

46 HP MSA 500 G2 Storage System Maintenance and Service Guide Parameter Value Weight (no drives installed) 22.7 kg (50 lb) Power Specifications

Strona 42

47 Acronyms and Abbreviations ACU Array Configuration Utility ADG Advanced Data Guarding ADU Array Diagnostics Utility ASIC application specif

Strona 43 - Component Identification 43

48 HP MSA 500 G2 Storage System Maintenance and Service Guide ECC error checking and correcting EMU environmental monitoring unit HBA host bus ad

Strona 44

Acronyms and Abbreviations 49 NFPA National Fire Protection Association NIC network interface controller NLM NetWare Loadable Module NVRAM non-vo

Strona 45 - Specifications

5 Illustrated Parts Catalog In This Section Mechanical and System Components...

Strona 46 - Power Specifications

50 HP MSA 500 G2 Storage System Maintenance and Service Guide SE single-ended SIM Systems Insight Manager SMART self-monitoring analysis and repo

Strona 47 - Acronyms and Abbreviations

51 DMA activity LED 38 drive bays 29, 40 logical I/O activity LED 38 Index 2 2-Port Shared Storage Module 18, 33, 34 4 4-Port Shared

Strona 48

52 HP MSA 500 G2 Storage System Maintenance and Service Guide M Management Agents 24 management tools 23 O Online ROM Flash Component Util

Strona 49

6 HP MSA 500 G2 Storage System Maintenance and Service Guide Item Description Spare Part Number Mechanical Components 1 Chassis, 4U, with

Strona 50

7 Removal and Replacement Procedures In This Section Safety Considerations...

Strona 51

8 HP MSA 500 G2 Storage System Maintenance and Service Guide • Place parts on a grounded surface before removing them from their containers. • Av

Strona 52

Removal and Replacement Procedures 9 WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health

Komentarze do niniejszej Instrukcji

Brak uwag