HP FlexFabric 5900CP Solutions
Configuration Guide
Abstract
This document describes HP FlexFabric 5900CP switch usage in converged Ethernet and storage network configurations. It
provides information about switch features and storage configurations, including the device support.
HP Part Number: 5697-3386
Published: November 2014
Edition: 2
Przeglądanie stron 0
1 2 3 4 5 6 ... 46 47

Podsumowanie treści

Strona 1 - Configuration Guide

HP FlexFabric 5900CP SolutionsConfiguration GuideAbstractThis document describes HP FlexFabric 5900CP switch usage in converged Ethernet and storage n

Strona 2

Table 2 HP FlexFabric 5900CP use-cases5900CPSwitch ModeStorage ConnectServer ConnectVariantMajor SAN FabricUse-CaseFCFNative FCoERack/CNA1A: Rack Serv

Strona 3 - Contents

Figure 4 HP FlexFabric 5900CP FCF Use-Case 1ALANFCoE StorageIRFIRF*VF_PortVF_PortVN_PortVN_PortExpandswitcheshorizontallyas required5900CP FCFFCoEConv

Strona 4 - Features and benefits

Figure 6 HP FlexFabric 5900CP FCF Use-Case 2AFCoE StorageIRFIRF*VF_PortVF_PortVN_PortVN_PortExpandswitcheshorizontallyas required5900CP FCFFCoEConverg

Strona 5

Figure 7 HP FlexFabric 5900CP FCF Use-Case 2BFC StorageIRFIRF*F_PortF_PortN_PortN_PortExpandswitcheshorizontallyas required5900CP FCFFCoE/FCConverged

Strona 6

Figure 8 HP FlexFabric 5900CP NPV Use-Case 3AFC StorageIRFIRF*NP_PortNP_PortF_PortF_PortN_PortN_PortExpandswitcheshorizontallyas requiredServer/HBA Se

Strona 7 - 2 Port types and switch modes

Converged or Native FC server connection options (Use-cases 3A and 3B):• Virtual Connect 20/40 F8• Virtual Connect Flex - 10/10D, FCoE• Virtual Connec

Strona 8 - Fibre Channel

Figure 11 HP FlexFabric 5900CP FCF Maximum FCoE Hop Count Use-Case 4A5900CP4AVN_PortVN_PortFCoEStorageConverged Ethernet/FCoE Native EthernetFCoE IRF

Strona 9 - 3 Storage use-cases

Figure 12 HP FlexFabric 5900CP FCF Maximum FC Hop Count Use-Case 4B5900CP4BIRF*2345900CP FCFNative FC234Expand switches horizontally as required.11LAN

Strona 10

Figure 13 HP FlexFabric 5900CP FCF Maximum FCoE Hop Count Use-Case 5A5900CP5AVN_PortVN_PortFCoEStorageConverged Ethernet/FCoE Native EthernetFCoE IRF

Strona 11 - 5900CP1b

Figure 14 HP FlexFabric 5900CP FCF Maximum FC Hop Count Use-Case 5B5900CP5BIRF*2345900CP FCFNative FC234Expand switches horizontally as required.11LAN

Strona 12 - 5900CP2A

© Copyright 2014, Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or copyi

Strona 13 - 5900CP2b

4 IRF usage with storageThe HP FlexFabric 5900CP switch supports IRF for use with Ethernet and storage networks. ForEthernet networks, you can configu

Strona 14 - 5900CP3B

• Must be specific on device placement to allow desired access such as CNA to storage• Allows Ethernet usage of the IRF linksConsiderations• Not consi

Strona 15 - 5900CP3D

Figure 17 Dual-redundant storage fabric configuration, 4-Switch IRF for Ethernet-only5900CP7CFabric-A “Virtual Switch” Fabric-B “Virtual Switch

Strona 16 - Rack Server/CNA

irf-port 1/2port group interface FortyGigE1/0/50interface FortyGigE1/0/50priority-flow-control autopriority-flow-control no-drop dot1p 3irf-port 2/2po

Strona 17 - Rack Server/HBA

5 c-Class BladeSystem interconnectsThe HP FlexFabric 5900CP switch supports connectivity to multiple HP server interconnect optionsincluding Virtual C

Strona 18 - • 6125XLG, FCoE (NPV or FCF)

6 HP FlexFabric 5900CP Storage Network SupportThe following section describes the operating system and the hardware support for the HP FlexFabric5900C

Strona 19 - Native FC

• HP QMH2572 8Gb FC HBA• HP BLc QLogic QMH2562 8Gb FC HBA Opt• HP 82Q 8Gb Dual Port PCI-e FC HBA• HP PCIe 2-port 8Gb FC SR (QLogic) HBA• HP 81Q PCI-e

Strona 20 - 4 IRF usage with storage

HP FlexFabric HP Storage System SupportHP FlexFabric HP Storage System Support:• 3PAR StoreServ 10400/10800 FCoE/Fibre Channel/iSCSI• 3PAR 7200/7400/7

Strona 21 - FC and FCoE Storage

7 Software and Firmware update processFirmware Update Process – Non ISSUThe non-ISSU firmware update process is disruptive if you have implemented a s

Strona 22 - VSAN1 VSAN2 VSAN3 VSAN4

8 Management SoftwareThe primary management interface for the HP FlexFabric 5900CP switch is through the CommandLine Interface (CLI). To access the CL

Strona 23 - VSAN 2 VSAN 2 VSAN 3 VSAN 3

Contents1 HP FlexFabric 5900CP switch overview...4Features and benefits...

Strona 24

3. Configure scheme authentication for VTY login users. The default authentication scheme ispassword authentication.4. Assign a user role to VTY login

Strona 25

A HP FlexFabric 5900CP system architecture considerationsRemarksParameter valueParameter name/typeE-port utilizes one Login, reduce thenumber by one f

Strona 26 - Fibre Channel Switches

RemarksParameter valueParameter name/typeto avoid storage traffic flow over IRFlinks.By default, the maximum number ofselected ports for an aggregatio

Strona 27

RemarksParameter valueParameter name/typeBy default, the number of concurrentlogins is not limited for the local user.access-limit max-user-number 16r

Strona 28

B Support informationThe HP FlexFabric 5900CP switch provides various display capabilities. You can use the displaysto identify issues by viewing conf

Strona 29 - 8 Management Software

In the following examples, two configuration files are named after the switch number. Theconfig87.cfg file is the primary file representing how the sw

Strona 30 - IMC Management software

C HP FlexFabric 5900CP switch configuration fileThis appendix shows some sections from the HP FlexFabric 5900CP switch configuration file.Use this as

Strona 31

zoneset activate name 5900CP_vsan100##vlan 1#vlan 1001description ToLAN#There shall be an FCoE enabled VLAN associated with each vsanconfigured regard

Strona 32

remark dot1p 3#qos policy DCBXclassifier DCBX behavior DCBX mode dcbx#Configure Console Connectivityline class auxuser-role network-admin#line class v

Strona 33

execute password simple <your password> and it will put it in theconfig file similar to below.password hash$h$6$im0rLRRRYOJHIwCY$zjEOgLLx7RF5dm5

Strona 34 - B Support information

1 HP FlexFabric 5900CP switch overviewThe HP FlexFabric 5900CP switch is a multipurpose converged L2/L3 switch with 48 convergedports and four 40 GbE

Strona 35

stp edged-portlldp tlv-enable dot1-tlv dcbxqos trust dot1pqos wrr be group 1 byte-count 15qos wrr af1 group 1 byte-count 15qos wrr af2 group spqos wrr

Strona 36

fc mode npport trunk vsan 100bind interface FortyGigE 1/0/49#To create an aggregation group follow these steps:1. Create the link-aggregation interfac

Strona 37 - Configure DCBx

interface Ten-GigabitEthernet 1/0/2port link-mode bridgeport link-type trunkport trunk permit vlan 1 1001 4001port trunk pvid vlan 1001priority-flow-c

Strona 38

GlossaryThis glossary defines acronyms and terms used in this guide. It is not a comprehensiveglossary of computer terms.AACL Access Control List. A l

Strona 39

such as PFC configuration and link bandwidth. You can configure DCB to set specific bandwidthto be allocated to packets depending on their priority va

Strona 40

ISSU In-Service Software Upgrade. A comprehensive transparent software upgrade capability fornetwork switches. IRF assisted ISSU will reboot one unit

Strona 41

PPFC Priority flow control. An extension of the 802.3x mechanism and defined in IEEE 802.1Qbb todefine a lossless Ethernet connection. The PAUSE frame

Strona 42

to the same VLAN. Traffic between VLANs must be routed. LAN port VLAN membership is assignedmanually on a port-by-port basis.vN_Port Virtual Node Port

Strona 43 - Glossary

• No additional feature licenses. The following four switch modes are available:Standard—Configurable DCB switch◦◦ FCF—FC/FCoE initiator; target; Flex

Strona 44 - 44 Glossary

(ISLs) (VE_Ports) to other 5900CP or 5900AF switches, the 6125XLG, or via NPV (VNP_Ports) toother HP FCoE switches that support NPIV. When configured

Strona 45

2 Port types and switch modesTo support LAN and SAN environments, the HP FlexFabric 5900CP switch utilizes multiple porttypes and switch modes.Port ty

Strona 46 - 46 Glossary

FCoE• HP FlexFabric 5900CP VF_Port to a VN_Port on a node.• HP FlexFabric 5900CP (NPIV) VF_Port to a VNP_Port on an NPV switch or module.• HP FlexFabr

Strona 47

3 Storage use-casesThe HP FlexFabric 5900CP switch supports several converged Ethernet/FCoE and Fibre Channelstorage configurations. To simplify under