1.
Low-profile x8 PCI-Express slot
2.
Eight PC2-5300 FB-DIMMs (DDR2 667) slots
3.
Up to two Intel Quad-Core or Dual-Core Xeon™ processors
4.
Slide-out System Insight Display
5.
Slimline removable media bay
6.
Up to six SAS/SATA hot plug drive bays
7.
Removable fans for easy serviceability
8.
Choice of Smart Array P400i Controller or Smart Array
E200i Controller
9.
Redundant Hot Plug Power Supplies (upgradeable option)
10.
Full length/height x8 PCI-Express Slot (optional PCI-X)
What's New
New Quad-Core Intel Xeon 5300 sequence processor models are now available with 1333GHz Front Side Bus speed, with
8M (2x4MB) L2 Cache (X5355 120W, E5345 80W, E5335 80W)
At A Glance
Combining concentrated 1U compute power, integrated Lights-Out management, and essential fault tolerance, the DL360 is
optimized for space constrained installations. Dual-core Xeon processors, DDR2 Fully Buffered DIMMs, Serial Attached SCSI (SAS)
and PCI Express technology provide a high performance system ideal for the full range of scale out applications. What's more, the HP
ProLiant DL360 G5 steps up the fault tolerant in an ultra dense platform with redundant power, redundant fans, mirrored memory or
online spare memory, embedded RAID capability, and full-featured remote Lights-Out management.
Processors:
Up to (2) Quad-Core or Dual-Core Intel® Xeon® processor 5000 sequence
Up to (2) Quad-Core Intel Xeon processor 5300 sequence
Intel 5000P chipset supporting up to a 1333MHz front-side bus
Memory:
Up to 32 GB of memory, supported by (8) slots of PC2-5300 Fully Buffered DIMMs (DDR2-667); 4:1 interleaving;
memory mirroring; online spare
Storage Controller:
Performance Models: HP Smart Array P400i/256MB BBWC Controller (RAID 0/1/1+0/5/6) (512MB BBWC
optional)
QuickSpecs
HP ProLiant DL360 Generation 5
Overview
DA - 12476 Worldwide QuickSpecs — Version 16 — 1/16/2007
Page 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 48 49

Podsumowanie treści

Strona 1 - QuickSpecs

1.Low-profile x8 PCI-Express slot2.Eight PC2-5300 FB-DIMMs (DDR2 667) slots3.Up to two Intel Quad-Core or Dual-Core Xeon™ processors4.Slide-out System

Strona 2

UPS Power Cord MatrixPlease see the UPS Power Cord Matrix for cable descriptions, requirements, and specifications for UPSunits:ftp://ftp.compaq.com/p

Strona 3

Rack Airflow RequirementsRack 10000 series CabinetsThe increasing power of new high-performance processor technology requires increased coolingefficie

Strona 4

HP ProLiant SmartBuys (NA only)The HP Smart Buy program offers mainstream business solutions at competitive prices with excellentavailability and supe

Strona 5

offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidaysDeployment Services – HP Installation and Start Up services designed

Strona 6

NOTE: ProLiant Smart Buys are available in NA only. For detailed specification information on ProLiant Smart Buys please click onthe following link: f

Strona 7

HP DL360 G5 BaseModelsQuad-Core ModelsDL360R05 E5335 2GB435943-xx1DL360R05 E5320 1GB438313-xx1Dual-Core ModelsDL360R05 5160 1GB416565-xx1DL360R05 5150

Strona 8

HP DL360 G5 EntryModelsQuad-Core ModelsDL360R05 E5310 1GB438312-xx1Dual-Core ModelsDL360R05 5130 1GB416561-xx1DL360R05 5120 1GB416560-xx1DL360R05 5110

Strona 9

NOTE: For Configure to Order requirements within EMEA region, please consult local Sales Contact.NOTE: HP does not allow factory integration of option

Strona 10

HP Smart Array E200 64MB FIO CacheNOTE: Supports Smart Array E200 Controller only.405102-B21128MB Battery Backed Write Cache Enabler Option KitNOTE: S

Strona 11

NOTE: Some options may not be factory integratable. Contact your local sales representative for additional information.HP ProLiant DL360G5 Unique Opti

Strona 12

Base Models: HP Smart Array P400i/256MB Controller (RAID 0/1/1+0/5) (512MB BBWC optional)Entry Models: HP Smart Array E200i/64MB Controller (RAID 0/1/

Strona 13

NOTE: For additional ProLiant Intelligent Networking Pack – Linux License Kits pleasesee the QuickSpecs at:http://h18000.www1.hp.com/products/quickspe

Strona 14

NOTE: This license allows 1 server to be migrated from a physical server to a virtualmachine. Or this license can be used to migrate a virtual machine

Strona 15

HP Insight Power Manager Pack, No Media, Single-Server LicenseNOTE: This option kit includes 1 license for Insight Power Manager.433691-B21NOTE: For a

Strona 16

Optical DrivesSlimline CD-RW/DVD-ROM Combo Option Kit331903-B21Slimline DVD-ROM Drive (8X/24X) Option Kit264007-B21HP DVD+R/RW 8X Slim383975-B21 Sliml

Strona 17

512 MB Battery-Backed Cache UpgradeNOTE: This 512-MB Battery-Backed Cache Module upgrade kit supports the SmartArray P600 Controller and the Smart Arr

Strona 18

http://h18000.www1.hp.com/products/quickspecs/10429_div/10429_div.HTML(SCSI Adapter)http://h18000.www1.hp.com/products/quickspecs/11555_div/11555_div.

Strona 19

NOTE: Connecting hard drive cage and SAS tape to the same SAS Controller usingsplit cable (supplied with tape drive) deactivates 1 of the hard drive b

Strona 20

HP StorageWorks 1U USB Rack-Mount KitNOTE: The 1U USB Rack-Mount Kit can support up to (2) half-height tape drives and iscompatible with the DAT 24 US

Strona 21

Tape LibrariesHP StorageWorks MSL2024 Tape LibraryHP StorageWorks MSL2024 1 Ultrium 960 Drive LibraryAG115AHP StorageWorks MSL2024 1 Ultrium 960 4GB F

Strona 22

HP StorageWorksModular Smart Array 20HP StorageWorks Modular Smart Array 20NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,

Strona 23

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information – FactoryIntegrat

Strona 24

Cluster OptionsProLiant Cluster Starter Kit364023-B22NOTE: For additional information regarding the ProLiant Cluster Starter Kit please seethe followi

Strona 25

Uninterruptible PowerSystems – RackMountableHP, R1.5kVA UPS, 1U, NAAF419AHP, R1.5kVA UPS, 1U, INTLAF418AHP, R1.5kVA UPS, 1U, JPN/TWAF421AHP R3000 VA U

Strona 26

Modular PDUs 1U/0U(Up to 32 outlets)NOTE: 1U/0U mountingbrackets shipped withthe unit (optimized for10000 and 9000 seriesracks).Fixed Cord Extension B

Strona 27

HP Rack 5000 Series(Graphite Metallic)HP 5642 Rack Unassembled358254-B21NOTE: Please see the HP Rack 5642 QuickSpecs for additional part numbers andTe

Strona 28

NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such asheight, width, depth, weight, and color:http://h18000.www1.hp.com/produ

Strona 29

HP KVM Switch Options2x1x16 IP Console Switch with Virtual MediaAF601A4x1x16 IP Console Switch with Virtual MediaAF602A2x16 Server Console Switch with

Strona 30

Service and SupportOfferings (HP Care PackServices)Hardware Services 4-Hour On-site Service4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years,

Strona 31

NOTE: Memory configurations listed do not apply to "Factory Integrated Models".NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) r

Strona 32

HP ProLiant DL360 G5 Performance ModelsStandard Memory2 GB PC2-5300 Fully Buffered DIMMs (DDR2-667) (2 x 1 GB)Upgrading Memory and Memory Interleaving

Strona 33

ConfigurationBranch 0Bank A1A and 3ABranch 0Bank C2C and 4CBranch 1Bank B5B and 7BBranch 1Bank D6D and 8D1*X-- -2X X- -3X X X X*NOTE: Configuration 1

Strona 34

MemoryTypePC2-5300 Fully Buffered DIMMs (DDR2-667)Standard (Entry or BaseModels)1 GB (2 x 512 MB)Standard (PerformanceModels)2 GB (2 x 1 GB)Standard (

Strona 35

1-66 x SFF SAS Hot Pluggable Hard Drive BaysASlimline Bay: Optional optical or floppy drive Drive Support QuantitySupportedPositionSupportedController

Strona 36

Serial-ATA (SATA) Hard Drive QuantitySupportedPositionSupportedController60GB 1.5G SATA 5.4K61-6HP Smart Array E200i/64MB ControllerHP Smart Array P40

Strona 37

Modular Smart Array1000Please see theModular SmartArray 1000QuickSpecsbelow todetermineconfigurationrequirementsExternalPlease see the Modular Smart

Strona 38

HP StorageWorks TapeDrives, ExternalDAT 24 USBDAT 40 USBDAT 72 USBExternalUSB 2.0 PortN/A HP StorageWorks TapeDrives, SAS ExternalUltrium 448 SASUltri

Strona 39

MSL6000 (SDLT 600-based)QuickSpecsHP ProLiant DL360 Generation 5StorageDA - 12476 Worldwide QuickSpecs — Version 16 — 1/16/2007Page 44

Strona 40

To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at URL:http://h30099.www

Strona 41

System UnitDimensions (H x W x D)1.70 x 16.78 x 27.75 in (4.32 x 42.62 x 70.49 cm)WeightMaximum (six hard drivesinstalled, two powersupply, two proces

Strona 42

environment. Noise emissions were measured in accordance with ISO 7779(ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).Idle: L WAd (BELS)

Strona 43

Smart Array P400iControllerDisk Drive and EnclosureInterface3G SAS (Serial Attached SCSI)1.5G SATA (Serial Advanced Technology Attachment)SAS Connecto

Strona 44

© Copyright 2007 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Windows N

Strona 45

Storage ControllerOne of the followingdepending on ModelPerformance Models:HP Smart Array P400i/256MB BBWC Controller (RAID 0/1/1+0/5/6)Available upgr

Strona 46

SoftwareManagerextensible environment to centrally manage servers, storage and otherinfrastructure devices across multiple operating system platforms.

Strona 47

ROMPaq, supportsoftware, andconfiguration utilitiesThe latest software, drivers, and firmware fully optimized and tested for yourProLiant server and o

Strona 48

processed and sent to the network.Remote Directory Memory Access (RDMA) Pack for EmbeddedMultifunction Gigabit Server Adapters – provides direct and f

Strona 49

Remote ManagementIntegrated Lights Out 2 (iLO2) Standard Management:Virtual Text Remote ConsoleVirtual Power Button ControlIntegrated Remote ConsoleDe

Komentarze do niniejszej Instrukcji

Brak uwag