HP TippingPoint Next Generation Firewall Series Instrukcja Instalacji Strona 30

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 54
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 29
18 HP TippingPoint S8000 Series
The management port LEDs indicate link and activity state, as described in the following table.
Eight 1GbE SFP fiber ports and four 10GbE SFP+ ports are also available on the S8000 Series
appliances.
Model Requirements
The following topics describe the power and cabling requirements for the S8000 Series appliances.
•”Power Requirements” on page 18
•”Cabling Requirements” on page 18
Power Requirements
The S8000 Series appliances require one input of Alternating Current (AC) that must meet the following
requirements:
AC: Voltage 100V – 240V; 12 – 6 amp; 47 – 63 Hz
WARNING! Do not attempt to install a DC power supply into an NGFW Appliance. The NGFW
Appliance does not contain the grounding capability for safe installation of a DC power supply. Bodily
harm and damage to the system could result.
Cabling Requirements
The S8000 Series appliances ship with the following cables:
Two AC power cables, one for each hot-pluggable power supply
Null modem cable for the serial console management port (DB-9 to RJ-45)
Table 4-1 Management Port LED Descriptions
LED Type Color Description
Link Green Link is active at 1000Mbps.
Off Link is inactive, or is active at 10Mbps or 100Mbps.
Activity Blinking amber Data traffic is passing.
Off No traffic is passing.
Przeglądanie stron 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 53 54

Komentarze do niniejszej Instrukcji

Brak uwag