HP HyperFabric Instrukcja Instalacji Strona 28

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 27
Planning the Fabric
TCP / IP
Chapter 2
28
Maximum Cable Lengths:
HF1 (copper): The maximum distance between two nodes or between a node and a
switch is 60 ft. (2 standard cable lengths are sold and supported: 35 ft. and 60 ft.)
TCP/IP supports up to four HF1 switches connected in series with a maximum cable
length of 60 ft. between the switches and 60 ft. between switches and nodes.
HF2 (fibre): The maximum distance is 200m (4 standard cable lengths are sold and
supported: 2m, 16m, 50m and 200m).
TCP/IP supports up to four HF2 switches connected in series with a maximum cable
length of 200m between the switches and 200m between switches and nodes.
TCP/IP supports up to 4 hybrid HF1/HF2 switches connected in series with a
maximum cable length of 60 ft. between copper ports and 200m between fibre ports.
Przeglądanie stron 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 155 156

Komentarze do niniejszej Instrukcji

Brak uwag