HP Moonshot 1500 Chassis
Setup and Installation Guide
Abstract
This document contains setup, installation, and configuration information for the HP Moonshot System. This document is for th
e person who installs,
administers, and troubleshoots the HP Moonshot System. HP assumes you are qualified in the servicing of computer equipment and trained in
recognizing hazards in products with hazardous energy levels.
Part Number: 711993-004
June 2014
Edition: 4
Przeglądanie stron 0
1 2 3 4 5 6 ... 63 64

Podsumowanie treści

Strona 1 - Setup and Installation Guide

HP Moonshot 1500 Chassis Setup and Installation Guide Abstract This document contains setup, installation, and configuration information for the HP

Strona 2

Identifying components and LEDs 10 Chassis front panel components Item Description 1 Bezel ear 2 Backplane assembly release lever 3 Serial label

Strona 3 - Contents

Identifying components and LEDs 11 Item Description LED Status 4 Cartridge health LEDs Green = Normal operation Amber = Standby mode Flashing Amb

Strona 4 - Contents 4

Identifying components and LEDs 12 Fan bay numbering Fan LED Status Description Off The fan is working or the power is off. Solid amber The fan

Strona 5 - Planning the installation

Identifying components and LEDs 13 Power supply LED Status Description Off • No AC power to power supply units. Check the AC power co

Strona 6 - Warnings and cautions

Identifying components and LEDs 14 Item Component Description 1 Serial console port For management 2 SFP+ ports X1–X6 1Gb or 10Gb Ethernet

Strona 7 - Planning the installation 7

Identifying components and LEDs 15 Moonshot-4QSFP+ Uplink Module components Item Component Description 1 Serial console port For management

Strona 8 - Grounding requirements

Identifying components and LEDs 16 Item Description Status 1 Uplink module UID LED/button Solid blue = Switch module ID is selected. Flashing blu

Strona 9

Identifying components and LEDs 17 HP Moonshot 1500 Chassis Management module LEDs and buttons Item Description Label 1 iLO CM management port

Strona 10 - Item Description

Identifying components and LEDs 18 Cartridge slot and switch module bay identification The chassis provides 45 cartridge slots (1-45) and two switch

Strona 11

Identifying components and LEDs 19 Cartridge LEDs and buttons Item Description Status 1 Cartridge power LED/button Green = Normal operation A

Strona 12 - Power supply bay numbering

© Copyright 2013, 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Strona 13 - Power supply LED

Identifying components and LEDs 20 Switch module button, sensor, and LEDs Item Description Status 1 Switch module power LED Green = Normal opera

Strona 14 - • HP 10GBASE-SR SFP+

Installing the chassis 21 Installing the chassis Installation overview To set up and install the chassis: 1. Unpack the Moonshot System ("Unpa

Strona 15 - • HP 40GBASE QSFP+ DAC

Installing the chassis 22 WARNING: The chassis is very heavy. To reduce the risk of personal injury or damage to the equipment, do the following:

Strona 16 - Item Description Label

Installing the chassis 23 1. Fully extend the rails by pressing the push tabs and extending the rails until the rails click two times. WARNING:

Strona 17 - Chassis internal components

Installing the chassis 24 2. Install the chassis into the J-slot on the rails, and then pull it forward. 3. Push in the release lever, and the

Strona 18

Installing the chassis 25 Installing the blanking panel If the rack rail adapter kit is not installed on the rack, always install the blanking p

Strona 19 - Cartridge LEDs and buttons

Installing the chassis 26 2. Attach a cage nut to each side of the rack. 3. Align the blanking panel. 4. Secure the blanking panel to the rack.

Strona 20

Installing the chassis 27 Maintenance and Service Guide or cartridge-specific user and maintenance guides in the HP Moonshot Information Library (ht

Strona 21 - Installing the chassis

Installing the chassis 28 To install the component: Install the power supply into the device bay, and then press firmly until the power supply is se

Strona 22 - • Blanking panel

Installing the chassis 29 Installing the cartridge To install the component: 1. Prepare the cartridge. 2. Align and install the cartridge into th

Strona 23 - Installing the chassis 23

Contents 3 Contents Planning the installation ...

Strona 24 - Installing the chassis 24

Installing the chassis 30 • Always install the switch module and the uplink module in corresponding bays. Both components must be installed for nor

Strona 25 - Installing the chassis 25

Installing the chassis 31 Production network mapping The first network interface discovered by the operating system routes traffic through switch A

Strona 26 - Installing the chassis 26

Installing the chassis 32 Management network mapping All traffic from the service port management interface is routed through the iLO CM management

Strona 27 - Installing a power supply

Installing the chassis 33 CAUTION: For proper cooling, be sure every switch module bay and uplink module bay has either a blank or a module ins

Strona 28 - Installing the fans

Installing the chassis 34 To install the component: 1. Locate the switch module slot, and then remove the blank. 2. Prepare the switch module for

Strona 29 - Installing the cartridge

Installing the chassis 35 3. Align and install the switch module into the chassis. 4. Do one of the following: o If the uplink module is already

Strona 30 - Installing the chassis 30

Cabling the HP Moonshot System 36 Cabling the HP Moonshot System Cabling overview WARNING: To reduce the risk of electric shock or injury due to

Strona 31 - Production network mapping

Cabling the HP Moonshot System 37 Moonshot iLO CM firmware SSH sessions and switch SSH sessions share connectivity through the iLO CM management por

Strona 32 - Installing the uplink module

Cabling the HP Moonshot System 38 • Moonshot 4QSFP+ Uplink Module Connecting power cables and applying power to the chassis 1. Connect the power

Strona 33 - Installing the switch module

Configuring the HP Moonshot System 39 Configuring the HP Moonshot System Chassis configuration overview To configure the HP Moonshot System, complet

Strona 34 - To install the component:

Contents 4 Installing network components ...

Strona 35

Configuring the HP Moonshot System 40 Log in to the iLO CM firmware After the terminal session is started, log in as administrator at the login prom

Strona 36 - Cabling overview

Configuring the HP Moonshot System 41 Always use the recommended firmware version for all Moonshot System components. For more information on recomm

Strona 37

Configuring the HP Moonshot System 42 For detailed configuration information, see the Switch Administrator's Guide and Switch CLI Guide in the

Strona 38 - Power-on events

Configuring the HP Moonshot System 43 enable password {password} Updating the switch firmware using the switch console Use TFTP, SFTP, or SCP to up

Strona 39 - Configure the chassis

Configuring the HP Moonshot System 44 Power capping The HP Moonshot System provides a power capping feature that operates at the chassis level. The

Strona 40 - 2. Obtain MAC addresses:

Configuring the HP Moonshot System 45 Example: hpiLO-> show chassis power Chassis: #------- Power in use: 170 Watts Power Capacity: 1818

Strona 41 - Configure the switch

Troubleshooting 46 Troubleshooting Troubleshooting resources The HP Moonshot System Troubleshooting Guide provides procedures for resolving common p

Strona 42 - Access the CLI locally

Regulatory information 47 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Strona 43

Regulatory information 48 Valid date formats include the following: • YWW, where Y indicates the year counting from within each new decade, with 20

Strona 44 - Power capping

Electrostatic discharge 49 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Strona 45

Planning the installation 5 Planning the installation Safety and regulatory compliance For safety, environmental, and regulatory information, see Sa

Strona 46 - Troubleshooting

Specifications 50 Specifications Chassis environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°

Strona 47 - Regulatory information

Support and other resources 51 Support and other resources Before you contact HP Be sure to have the following information available before you call

Strona 48 - Communications interference

Support and other resources 52 NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP require

Strona 49 - Electrostatic discharge

Support and other resources 53 Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella so

Strona 50 - Specifications

Support and other resources 54 CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte

Strona 51 - Support and other resources

Support and other resources 55 Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su

Strona 52

Support and other resources 56 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Strona 53 - Customer Self Repair

Support and other resources 57

Strona 54

Support and other resources 58

Strona 55 - Reparo feito pelo cliente

Acronyms and abbreviations 59 Acronyms and abbreviations CM chassis management CPLD complex programmable logic device DHCP Dynamic Host Configurat

Strona 56

Planning the installation 6 covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992 (code for Protection of Electronic Computer/

Strona 57

Acronyms and abbreviations 60 TFTP Trivial File Transfer Protocol UPS uninterruptible power system

Strona 58

Documentation feedback 61 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Strona 59 - Acronyms and abbreviations

Index 62 A access panel 9 accessing the CLI 42 activity LED 10 administrator password 40 airflow requirements 7 authorized reseller 51 B

Strona 60

Index 63 firmware 40, 41, 43 firmware upgrade utility, troubleshooting 46 front panel components 10, 19 G grounding methods 49 grounding req

Strona 61 - Documentation feedback

Index 64 power supply LEDs 13 power supply, installing 27 power up procedure 38 powering up 38 Power-on events 38 preparation procedures

Strona 62 - Index 62

Planning the installation 7 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The rack is bolted to the

Strona 63 - Index 63

Planning the installation 8 HP rack products draw cool air in through the front and expel warm air through the rear of the enclosure. Therefore, the

Strona 64 - Index 64

Identifying components and LEDs 9 Identifying components and LEDs HP Moonshot System components Item Description 1 HP Moonshot 1500 Chassis 2