CLI commands
mesh id
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
mesh id <id>
Set the local mesh group id.
allowed downtime
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
allowed downtime <number>
Set the allowed downtime for a connection (or a link) to a peer.
minimum snr
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
minimum snr <number>
Slave: Set the group’s minimum SNR.
snr cost per hop
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snr cost per hop <number>
Slave: Set the group’s SNR cost per hop.
initial discovery time
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
initial discovery time <number>
Slave: Set the group’s initial discovery time in seconds.
active
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
active
Activates the local mesh group.
no active
Deactivates the local mesh group.
end
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
end
Switch to parent context.