HP 600B Instrukcje Operacyjne Strona 1

Przeglądaj online lub pobierz Instrukcje Operacyjne dla Części komputerowe HP 600B. HP 600B Operating instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1

OPERATING INSTRUCTIONS CONCERT SERIES600-HP Compact High-Power SubwooferKeep these important operating instructions.Check www.meyersound.com for updat

Strona 2 - April 15, 2006

4CHAPTER 1Figure 1.3. Flown array with MICA loudspeakers and 600-HP subwoofersFigure 1.4. Ground-stack with MICA loudspeakers and 600-HP subwoofersThe

Strona 3 - SYMBOLS USED

5CHAPTER 2Self-powered and highly portable, the 600-HP subwoofer incorporates advanced loudspeaker technology with equally advanced power capabilities

Strona 4 - SAFETY SUMMARY

6CHAPTER 2 NOTE: Refer to Appendix B for details on the 600-HP’s AC voltage requirements.After applying AC power, the proper operating voltage

Strona 5 - CONTENTS

7CHAPTER 2 CAUTION: In the unlikely event that the circuit breakers on the user panel trip (the white center buttons pop out), disconnect the AC power

Strona 6 - CHAPTER 7: QuickFly

8CHAPTER 2ELECTRICAL SAFETY ISSUESPay close attention to these important electrical and safety issues. CAUTION: Do not use a power cord adapter to dr

Strona 7

9CHAPTER 3The 600-HP uses sophisticated amplification and protec-tion circuitry to produce consistent and predictable results in any system design. Thi

Strona 8 - INTRODUCTION

10CHAPTER 3 NOTE: Most source equipment is safe for driving loads no smaller than 10 times the source’s output impedance. For example an equal

Strona 9 - CHAPTER 1

11CHAPTER 3TruPower limiting also eliminates power compression when the system is operated at high levels for extended periods, and extends the driver

Strona 10 - APPLICATIONS

12CHAPTER 3 NOTE: In the highly unlikely event that the secondary fan does not keep the tempera-ture below 85˚ C, the 600-HP automatically shu

Strona 11 - CHAPTER 2: POWER REQUIREMENTS

13CHAPTER 4The RMS communication module is standard in 600-HP subwoofers with the MRF-600 rigging frame installed and is optional in the other models,

Strona 12 - CURRENT REQUIREMENTS

iiDECLARATION OF CONFORMITY ACCORDING TO ISO/IEC GUIDE 22 AND EN 45014Manufacturer’s Name:Meyer Sound Laboratories Inc.Manufacturer’s Address:2832 San

Strona 13 - CHAPTER 2

14CHAPTER 4Service Button Pressing the Service button will notify the corresponding loudspeaker display icon on the RMS screen. When used in combinati

Strona 14 - ELECTRICAL SAFETY ISSUES

15CHAPTER 5USING 600-HP SUBWOOFERS WITH OTHER MEYER SOUND LOUDSPEAKERSIt is often necessary to augment mid-high or full-range systems with subwoofers

Strona 15 - AUDIO INPUT

16CHAPTER 5Figure 5.1. Array with 600-HP and MICA600-HP Used with Concert and UltraSeries LoudspeakersAll Meyer Sound self-powered products have been

Strona 16 -

17CHAPTER 5 NOTE: When driving Concert or UltraSeries loudspeakers from the Mid-Hi output of the LD-1A or LD-2 line driver, with the Lo-Cut fil

Strona 17 - 

18CHAPTER 5phase shift differences between the loudspeakers and the subwoofers. In addition, you should verify the delay time between channels. Some D

Strona 18

19CHAPTER 6Meyer Sound offers two comprehensive tools to assist you with the acoustical and functional requirements of system design and optimization.

Strona 19

20CHAPTER 6The key to MAPP Online Pro’s value is the accuracy of its predictions. Performance predictions for each Meyer Sound loudspeaker found in MA

Strona 20

21CHAPTER 7When fitted with the optional MRF-600 rigging frame, the 600-HP may be flown alone or with MICA curvilinear array loudspeakers. It may also b

Strona 21

22CHAPTER 7The front links may be set in two different positions: 0°: This is the standard position (left figure) and it is used to achieve a 0-degre

Strona 22

23CHAPTER 7This rigging capability allows all of the 600-HPs to be posi-tioned at 0 degrees in relation to each other and to the MG-MICA grid, while i

Strona 23

iiiSYMBOLS USEDThese symbols indicate important safety or operating features in this booklet and on the chassis:1. Read these instructions.2. Keep t

Strona 24

24CHAPTER 7THE MG-MICA MULTIPURPOSE GRID The MG-MICA multipurpose grid (Figure 7.7) allows multiple 600-HP subwoofers fitted with MRF-600 rigging frame

Strona 25

25CHAPTER 7Ground-Stacked ConfigurationThe MG-MICA ground-stacked pockets receive the 600-HP links directly (Figure 7.9). Many combinations are possibl

Strona 26 - Applications

26CHAPTER 7Whether you’re deploying or striking an array, the MCF-MICA can temporarily support its weight — making it easy to assemble or disassemble

Strona 27 - GUIDEALINK RIGGING FRAME

27CHAPTER 7 CAUTION: Avoid using the 600-HP front or rear link in the extended position (+3 in front and any setting other than 0 in the rear) when tr

Strona 28 - 600-HP to MICA

28CHAPTER 7Figure 7.17. Three 600-HP on the MDB-600 with strap NOTE: For safety reasons and to avoid any damage to the enclosures, use straps

Strona 29

29APPENDIX AUSING THE RAIN HOOD (WEATHER-PROTECTED LOUDSPEAKERS)If your 600-HP loudspeaker was ordered with optional weather protection, a rain hood

Strona 31 - MCF-MICA CASTER FRAME

31APPENDIX BAPPENDIX B: 600-HP SPECIFICATIONS ACOUSTICALOperating frequency range 36 Hz - 150 Hz Note: Recommended maximum operating frequency range

Strona 32 - 

32APPENDIX BAC POWERAC power connector 250 V NEMA L6-20 (twist lock), IEC 309 male inlet, PowerCon, or VEAMVoltage selection Automatic, two ranges, ea

Strona 34

ivEnglish- To reduce the risk of electric shock, disconnect the loudspeaker from the AC mains before installing audio cable. Reconnect the power cord

Strona 35

© 2006 Meyer Sound Laboratories Inc.05.149.005.01 AMeyer Sound Laboratories Inc.2832 San Pablo AvenueBerkeley, CA 94702www.meyersound.comT: +1 510 486

Strona 36 - APPENDIX A

vCONTENTSINTRODUCTION 1How to Use this Manual 1CHAPTER 1: Introducing the 600-HP Compact High-Power Subwoofer 3High Power and High Performance 3Ve

Strona 37 - APPENDIX B

viCHAPTER 7: QuickFly® Rigging and Ground-stacking 21Flying the 600-HP Subwoofer 21GuideALink™ Rigging Frame 21600-HP to 600-HP 22Flown 22Ground-

Strona 38

1INTRODUCTION These operating instructions provide important information about the form, features, function, and specifications of the 600-HP high-powe

Strona 39

2INTRODUCTION

Strona 40

3CHAPTER 1The 600-HP is a self-powered, high-output subwoofer that may be used in both flown and ground-stacked configurations. It is designed to rig di

Komentarze do niniejszej Instrukcji