2
Operating System Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack
SP6a or later.
SPU
Model HP NetServer LXr 8500
Clock speed 400/450, 500/550, 700 MHz
No. of CPUs 2 – 8
BIOS version ASPN Release 8
CPU cache Any size
RAM 128 MB minimum. Must be HP.
No. of power supplies 3 required for redundancy
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, PCI-1, PCI-2, SCSI A, SCSI B, PCI-3, PCI-4, PCI-5
through PCI-10
M/S Certified
Configuration
P6 – Shared Storage HBA
P4 – Intra-cluster (Heartbeat) LAN
P3 – Client LAN
P2 – HP TopTools Control card D6028A (optional)
Booted from embedded SCSI
Storage
Local
Controller May use embedded SCSI, NetRAID-1Si or NetRAID-3Si.
Driver For embedded SCSI, use sym_hi.sys version 4.12 or later.
For NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack Storage/12FC Required – D5991A
Host Bus Adapter
Model HP Fibre Channel Host Bus Adapter - HP D8602A
No. of HBAs 1
Driver Hhba5100.sys 1.12 or later
RAID level 0, 1, 3, 5, 10
Cabinet
Model HP NetServer Rack Storage/12FC- D5991A
RAID arrays Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets 1
FC Array Cards