HP ProLiant Smart Array E200 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Części komputerowe HP ProLiant Smart Array E200. HP ProLiant Smart Array E200 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 65
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
HP ProLiant BL460c Server Blade
Maintenance and Service Guide
Part Number 405778-401
November 2008 (Tenth Edition)
Przeglądanie stron 0
1 2 3 4 5 6 ... 64 65

Podsumowanie treści

Strona 1 - Part Number 405778-401

HP ProLiant BL460c Server Blade Maintenance and Service Guide Part Number 405778-401 November 2008 (Tenth Edition)

Strona 2 - Intended audience

Customer self repair 10 periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de bijbehorende documentatie word

Strona 3 - Contents

Customer self repair 11 Serviço de garantia apenas para peças A garantia limitada da HP pode incluir um serviço de garantia apenas para peças. Segun

Strona 4 - Contents 4

Customer self repair 12

Strona 5 - Customer self repair

Customer self repair 13

Strona 6 - Customer self repair 6

Customer self repair 14

Strona 7 - Customer Self Repair

Customer self repair 15

Strona 8 - Customer self repair 8

Illustrated parts catalog 16 Illustrated parts catalog Server blade components Item Description Spare part number Customer self repair (on pa

Strona 9

Illustrated parts catalog 17 Item Description Spare part number Customer self repair (on page 5) c) 3.20-GHz Intel® Xeon® processor 5063 MV, dual-

Strona 10 - Reparo feito pelo cliente

Illustrated parts catalog 18 Item Description Spare part number Customer self repair (on page 5) w) 2.50-GHz Intel® Xeon® processor E5420, quad-co

Strona 11 - Customer self repair 11

Illustrated parts catalog 19 Item Description Spare part number Customer self repair (on page 5) g) 4-GB, PC2-5300, low-power, RoHS* 467654-001

Strona 12 - Customer self repair 12

© Copyright 2006, 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warra

Strona 13 - Customer self repair 13

Illustrated parts catalog 20 1Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be cha

Strona 14 - Customer self repair 14

Illustrated parts catalog 21 3No: Nee—Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de garantievoorwaarden

Strona 15 - Customer self repair 15

Removal and replacement procedures 22 Removal and replacement procedures Required tools You need the following items for some procedures: • T-15 To

Strona 16 - Illustrated parts catalog

Removal and replacement procedures 23 CAUTION: When performing non-hot-plug operations, you must power down the server blade and/or the system. Ho

Strona 17

Removal and replacement procedures 24 Power down the server blade Before powering down the server blade for any upgrade or maintenance procedures, p

Strona 18

Removal and replacement procedures 25 3. Remove the server blade. 4. Place the server blade on a flat, level work surface. WARNING: To reduce

Strona 19

Removal and replacement procedures 26 Hard drive blank CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade

Strona 20

Removal and replacement procedures 27 3. Remove the hard drive. To replace the component: 1. Prepare the hard drive.

Strona 21

Removal and replacement procedures 28 2. Install the hard drive. FBDIMM CAUTION: Use only HP FBDIMMs. FBDIMMs from other sources may adversel

Strona 22 - Safety considerations

Removal and replacement procedures 29 Hard drive backplane Some models of this server blade do not include a hard drive backplane. To remove the com

Strona 23 - Server blade preparation

Contents 3 Contents Customer self repair ...

Strona 24 - Remove the server blade

Removal and replacement procedures 30 To replace the component: 1. Install the hard drive backplane. Press down on the hard drive backplane retaine

Strona 25 - Access panel

Removal and replacement procedures 31 7. Remove the hard drive backplane retainer. To replace the component: 1. Install the hard drive backplane

Strona 26 - Hard drive

Removal and replacement procedures 32 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4

Strona 27 - Prepare the hard drive

Removal and replacement procedures 33 4. Remove the mezzanine card. To replace the component: 1. Install the mezzanine card. Press down on the co

Strona 28

Removal and replacement procedures 34 5. Remove all hard drive blanks ("Hard drive blank" on page 26). 6. Remove the hard drive backplan

Strona 29 - Hard drive backplane

Removal and replacement procedures 35 8. Remove the Smart Array E200i Controller battery pack. To replace the component, reverse the removal proce

Strona 30

Removal and replacement procedures 36 8. Remove the server blade handle. To replace the component, reverse the removal procedure. Release button

Strona 31

Removal and replacement procedures 37 8. Remove the release button. To replace the component, reverse the removal procedure. Heatsink WARNING:

Strona 32 - Mezzanine card

Removal and replacement procedures 38 8. Remove the heatsink. To replace the component: 1. Clean the old thermal grease from the processor with t

Strona 33

Removal and replacement procedures 39 3. Install the heatsink. 4. Install the front panel/hard drive cage assembly ("Front panel/hard drive

Strona 34

Contents 4 SAS and SATA hard drive LED combinations ... 56

Strona 35 - Server blade handle

Removal and replacement procedures 40 6. Remove the hard drive backplane ("Hard drive backplane" on page 29). 7. Remove the front panel/

Strona 36 - Release button

Removal and replacement procedures 41 1. If the processor has separated from the installation tool, carefully re-insert the processor in the tool.

Strona 37 - Heatsink

Removal and replacement procedures 42 3. Press down firmly until the processor installation tool clicks and separates from the processor, and then

Strona 38 - 8. Remove the heatsink

Removal and replacement procedures 43 6. Apply all the grease to the top of the processor in one of the following patterns to ensure even distribut

Strona 39 - Processor

Removal and replacement procedures 44 System board To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blad

Strona 40

Removal and replacement procedures 45 12. Using your fingers, remove the processor from the failed system board. CAUTION: To avoid damage to t

Strona 41

Removal and replacement procedures 46 1. Install the spare system board. 2. Prepare the processor socket on the spare system board: a. Open the

Strona 42

Removal and replacement procedures 47 b. Remove the processor socket protective cover. 3. Install the processor socket cover onto the processor s

Strona 43

Removal and replacement procedures 48 5. Close the processor retaining latch and the processor socket retaining bracket. 6. Clean the old thermal

Strona 44 - System board

Removal and replacement procedures 49 After you replace the system board, you must re-enter the server serial number and the product ID. 1. During

Strona 45

Customer self repair 5 Customer self repair HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow fo

Strona 46

Removal and replacement procedures 50 8. Remove the system board. 9. Identify the battery location ("System board components" on page 5

Strona 47

Diagnostic tools 51 Diagnostic tools Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving commo

Strona 48

Diagnostic tools 52 This functionality supports operating systems that may not be supported by the server blade. For operating systems supported by

Strona 49 - System battery

Diagnostic tools 53 HP Instant Support Enterprise Edition ISEE is a proactive remote monitoring and diagnostic tool to help manage your systems and

Strona 50 - 10. Remove the battery

Server component identification 54 Server component identification Front panel components Item Description 1 Hard drive bay 1 2 Power On/Stand

Strona 51 - Diagnostic tools

Server component identification 55 Front panel LEDs Item Description Status 1 UID LED Blue = Identified Blue flashing = Active remote manageme

Strona 52 - HP Systems Insight Manager

Server component identification 56 SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS and

Strona 53 - Open Services Event Manager

Server component identification 57 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Flashing irregularly Amber, flashing regula

Strona 54 - Front panel components

Server component identification 58 Item Description 12 Enclosure connector The symbols correspond to the symbols located on the interconnect

Strona 55 - Front panel LEDs

Server component identification 59 Position Function Default 5* Password disabled Off 6* Reset configuration Off 7 Reserved Off 8 Reserved Off

Strona 56 - SAS and SATA hard drive LEDs

Customer self repair 6 • Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces p

Strona 57 - System board components

Server component identification 60 HP c-Class Blade SUV Cable Item Connector Description 1 Server blade For connecting to the SUV connector on

Strona 58 - System maintenance switch

Specifications 61 Specifications Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (50°F to 95°F) Shippin

Strona 59 - Item Description

Acronyms and abbreviations 62 Acronyms and abbreviations ADU Array Diagnostics Utility BBWC battery-backed write cache CSR Customer Self Repair E

Strona 60 - HP c-Class Blade SUV Cable

Acronyms and abbreviations 63 PCI peripheral component interface PCIe peripheral component interconnect express RBSU ROM-Based Setup Utility ROM

Strona 61 - Specifications

Index 64 A access panel 25 ADU (Array Diagnostic Utility) 52 Array Diagnostic Utility (ADU) 52 B backplane, hard drive 29, 59 battery 49, 5

Strona 62 - Acronyms and abbreviations

Index 65 P Power On/Standby button 54 powering down 24 preparation procedures 23 processor socket 57 processors 39, 57 R release button 3

Strona 63

Customer self repair 7 NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richi

Strona 64 - Index 64

Customer self repair 8 anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert wer

Strona 65 - Index 65

Customer self repair 9 Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales para la su

Komentarze do niniejszej Instrukcji

Brak uwag