5. Read the controller LCD panel messages during the MSA startup routine.
• If the following messages are displayed, the serial number of the original chassis was
automatically transferred to the replacement chassis.
SPARE CHASSIS DETECTED
CHASSIS SERIAL NUMBER FLASHED UPDATED
IMPORTANT:
If these messages are displayed, the MSA1510i will automatically restart.
• If the following message is displayed, it may safely be ignored.
I2C WRITE FAILURE
• When the following message is displayed, the startup routine is complete.
STARTUP COMPLETE
Verifying proper operation
After replacing the failed chassis, verify that:
• No error messages are displayed on the controller LCD panels.
• The chassis Power LED is solid green.
• The chassis Heartbeat LED is blinking green.
• LEDs on each MSA module are showing a healthy status.
IMPORTANT:
If CHASSIS MISMATCH POWER OFF AND FIX is displayed on the controller LCD panel, persistent
datastoredonalloftheharddrivesdoesnotmatch.Theoriginalconfiguration was changed or startup
procedures were followed incorrectly. Power off the MSA1510i, correct any configuration changes,
and repeat the power-on sequence.