HP Designjet T Series — Service Manual 6-145
Removal and Installation - Scan-Axis Motor (T1100/T1100ps/T610)
12. Carefully pull the Scan-Axis Motor out of
the printer (10 mm) until you can rotate it
approximately 30 degrees
counterclockwise.
13. Remove the Scan-Axis Motor from the
printer.
When you finish installing or replacing this component, you must perform the
necessary Service Calibrations. To find which calibrations you must perform,
see Service Calibration Guide to Removal and Installation
on page 6-5.