Hp ProCurve 520wl Wireless Access Point Instrukcja Użytkownika Strona 181

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 180
Command Line Interface (CLI)
Other Parameters
IAPP Parameters
Name Type Values Access CLI Parameter
IAPP Group N/A R iapp
IAPP Status Integer enable (default)
disable
RW iappstatus
Periodic Announce
Interval (seconds)
Integer 80
120 (default)
160
200
RW iappannint
Announce Response
Time
Integer 2 seconds R iappannresp
Handover Time-out Integer 410 ms
512 ms (default)
614 ms
717 ms
819 ms
RW iapphandtout
Max. Handover
Retransmissions
Integer 1 - 4 (default 4) RW iapphandretx
Send Announce
Request on Startup
Integer enable (default)
disable
RW iappannreqstart
NOTE�
These parameters configure the Inter Access Point Protocol (IAPP) for roaming. Leave these settings at their
default value unless a technical representative asks you to change them.
SpectraLink VoIP Parameters (802.11b Only)
Name Type Values Access CLI Parameter
Spectralink VoIP Group N/A R spectralink
Spectralink VoIP Status Integer enable
disable (default)
RW speclinkstatus