56 3 - TROUBLESHOOTING INSTALLATION PROBLEMS
Similar
Problems
See also the following sections which describe similar problems:
“Problem: HP EFS WAN Accelerator Does Not Boot” on page 56
“Problem: HP EFS WAN Accelerator Boots Briefly, and Then Reboots” on
page 54
Problem: HP EFS WAN Accelerator Does Not
Boot
Description of
Problem
The HP EFS WAN Accelerator fails to boot.
Solution Ensure that:
The HP EFS WAN Accelerator is properly plugged in.
The power strip or that the uninterruptable power supply (UPS) the HP EFS WAN
Accelerator is plugged in to is turned on and is functioning properly.
Similar
Problems
See also the following sections which describe similar problems:
“Problem: HP EFS WAN Accelerator Boots Briefly, and Then Reboots” on
page 54
“Problem: HP EFS WAN Accelerator Boots, Displays the Login Prompt, and
Then Reboots” on page 55
Problem: HP EFS WAN Accelerator Does Not
Come Out of Bypass Mode
Description of
Problem
The HP EFS WAN Accelerator does not come out of bypass mode when the
connection is restored.
Solution If a HP EFS WAN Accelerator does not come out of bypass mode, verify:
That the in-path interface has an IP address. For example, at the system prompt,
enter the show interfaces CLI command.
That in-path interception in enabled. For example, at the system prompt, enter the
show in-path CLI command. Expected results are:
Enabled: yes
Optimizations Enabled On: inpath0_0