HP G2 Instrukcja Użytkownika Strona 92

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 91
92 HP StorageWorks MSA500 G2 Storage System User Guide
Action: Remove the failed controller.
20 Initializing SCSI Subsystem
Type: Informational
Description: The SCSI subsystem is being initialized as part of the power up
sequence.
Action: None
21 Scanning for SCSI Devices
Type: Informational
Description: The controller is scanning for hard drives.
Action: None
22 Initializing SCSI Devices
Type: Informational
Description: The controller is initializing the hard drives.
Action: None
24 Bad SCSI Bus Mode Non-LVD Device Found
Type: Error
Description: The MSA500 G2 storage system does not support SCSI SE
devices; it only supports SCSI LVD devices.
Action:
1. Power down the storage system (on page 28
).
Przeglądanie stron 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 152 153

Komentarze do niniejszej Instrukcji

Brak uwag