Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Hood Cover
1.
PCI Express expansion slot 1, low profile
2.
Up to two Intel Six-Core, Quad-Core or Dual-Core Xeon™
processors)
2.
PCI Express expansion slot 2 full-height full-length x16 (16,
8, 4, 2, 1), 75W +EXT 75W (option for PCI-X card only
support)
3.
Video connector
3.
Power supply bay 1 (populated)
4.
Slide-out System Insight Display (SID)
4.
Power supply bay 2
5.
Removable fan modules for easy serviceability
5.
iLO 3 NIC connector
6.
Eighteen DIMM slots: DDR3 Registered (RDIMM) or
Unbuffered (UDIMM) memory
6.
Serial connector
7.
Video connector
7.
Redundant Hot Plug Power Supplies (upgradeable option)
8.
NIC 4 connector
8.
2 PCI-E Slots
9.
NIC 3 connector
10.
NIC 2 connector
11.
NIC 1 connector
12.
USB connector
13.
USB connector
At A Glance
At A GlanceAt A Glance
At A Glance
The HP ProLiant DL360 G7 combines performance, intelligent power and cooling management with IT management tools and
essential fault tolerance, all optimized for space constrained installations. A 1U server with the improved performance of the latest
Intel 5600 series processors, Unique HP Thermal Logic Technologies that provide leadership in energy efficiencies and ProLiant iLO
3 remote management. HP continues to provide more performance, flexibility and efficiency for space constrained environments.
Processors
ProcessorsProcessors
Processors
:
Up to 2 Six-Core, Quad-Core or Dual-Core Intel® Xeon® 5600 or 5500 sequence processors
Intel® 5520 Chipset
Memory
MemoryMemory
Memory
:
18 DDR3 DIMM slots available for RDIMM or UDIMM memory devices
Memory speeds up to 1333MHz with select processors, memory DIMMs and population.
Up to 192GB, using 16GB Quad Rank PC3-8500R DDR3 Registered (RDIMM) memory, operating at 800MHz when
populated at 2 DIMMs per Channel in 12 slots.
Up to 48GB, using 4GB PC3-10600 DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when populated at
2 DIMMs per Channel in 12 slots.
QuickSpecs
HP ProLiant DL360 Generation 7 (G7)
HP ProLiant DL360 Generation 7 (G7)HP ProLiant DL360 Generation 7 (G7)
HP ProLiant DL360 Generation 7 (G7)
Overview
DA - 13598 Worldwide — Version 1 — May 11, 2010
Page 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - QuickSpecs

Front View:Front View:Front View:Front View:Rear View:Rear View:Rear View:Rear View:1.Hood Cover1.PCI Express expansion slot 1, low profile2.Up to two

Strona 2

Power SupplyPower SupplyPower SupplyPower SupplyHP's Common Slot Power Supply bay design provides the customer with commonality in power supplies

Strona 3

Required CablingRequired CablingRequired CablingRequired CablingFor required cabling information, refer to the Web site at:http://h18000.www1.hp.com/p

Strona 4

Factory Express PortfolioFactory Express PortfolioFactory Express PortfolioFactory Express Portfoliofor Servers and Storagefor Servers and Storagefor

Strona 5

http://www.hp.com/go/proliant/carepackQuickSpecsHP ProLiant DL360 Generation 7 (G7)HP ProLiant DL360 Generation 7 (G7)HP ProLiant DL360 Generation 7 (

Strona 6

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Strona 7

HP DL360 G7 EntryHP DL360 G7 EntryHP DL360 G7 EntryHP DL360 G7 EntryModelModelModelModelQuad-Core ModelsQuad-Core ModelsQuad-Core ModelsQuad-Core Mode

Strona 8

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Strona 9

processors.NOTE:NOTE:NOTE:NOTE: HT indicates that the processor model supports Intel® /Hyper-ThreadingTechnologyNOTE:NOTE:NOTE:NOTE: Turbo indicates t

Strona 10

HP 1200W CS HE Power Supply Kit500172-B21HP 1200W -48V DC CS Power Supply437573-B21NOTE:NOTE:NOTE:NOTE: Option Kits contain optional power supply, an

Strona 11

NOTE:NOTE:NOTE:NOTE: Some options may not be factory integratable. Contact your local sales representative for additional information.HP Unique Option

Strona 12

Storage ControllerStorage ControllerStorage ControllerStorage Controller:Entry Models: HP Smart Array P410i/Zero Memory Controller (RAID 0/1/1+0)Base

Strona 13

HP MemoryHP MemoryHP MemoryHP MemoryRegistered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)HP 2GB 2Rx8 PC

Strona 14

HP Hard DrivesHP Hard DrivesHP Hard DrivesHP Hard DrivesNOTE:NOTE:NOTE:NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller

Strona 15

HP NetworkingHP NetworkingHP NetworkingHP NetworkingGigabit Ethernet AdaptersGigabit Ethernet AdaptersGigabit Ethernet AdaptersGigabit Ethernet Adapte

Strona 16

HP Power SuppliesHP Power SuppliesHP Power SuppliesHP Power SuppliesCAUTION:CAUTION:CAUTION:CAUTION: Many HP ProLiant Servers now offer new power opti

Strona 17

HP Insight SoftwareHP Insight SoftwareHP Insight SoftwareHP Insight SoftwareHP Insight ControlHP Insight ControlHP Insight ControlHP Insight Control H

Strona 18

HP Insight Software Media KitNOTE:NOTE:NOTE:NOTE: Insight Software DVD media without licenses. Contains HP Systems InsightManager, HP Insight Control,

Strona 19

Smart Array P812 ControllerSmart Array P812 ControllerSmart Array P812 ControllerSmart Array P812 Controller HP Smart Array P812/1G Flash Backed Cache

Strona 20

HP Power CordsHP Power CordsHP Power CordsHP Power CordsNOTE:NOTE:NOTE:NOTE: The HP ProLiant DL360 G7 ships with an IEC-IEC power cord used for rackmo

Strona 21

Tape BackupTape BackupTape BackupTape BackupNOTE:NOTE:NOTE:NOTE: For the complete range of StorageWorks tape drives, autoloaders, librariesand media s

Strona 22

HP StorageWorks D2D4112fc Backup SystemNOTE:NOTE:NOTE:NOTE: 9.0TB (expandable to 18.0TB) of useable network disk backup capacity. FibreChannel SAN con

Strona 23

Supports Microsoft Windows, RHEL, SLES, OEL, Oracle Solaris, VMware, Microsoft Windows HyperV and CitrixXenServer, SLES XEN and Red Hat Virtualization

Strona 24

HP Disk Storage SystemsHP Disk Storage SystemsHP Disk Storage SystemsHP Disk Storage SystemsMSA SAN Storage ArraysMSA SAN Storage ArraysMSA SAN Storag

Strona 25

HP Power DistributionHP Power DistributionHP Power DistributionHP Power DistributionUnitsUnitsUnitsUnitsMonitored PDUsMonitored PDUsMonitored PDUsMoni

Strona 26

HP Rack OptionsHP Rack OptionsHP Rack OptionsHP Rack OptionsHP Server Console SwitchesHP Server Console SwitchesHP Server Console SwitchesHP Server Co

Strona 27

HP Care Pack ServicesHP Care Pack ServicesHP Care Pack ServicesHP Care Pack ServicesHardware Services 4-Hour On-site ServiceHardware Services 4-Hour O

Strona 28

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".DDR3 memory population guidelinesDDR3 memory p

Strona 29

NOTES:NOTES:NOTES:NOTES:Mixing DIMM speeds is allowed, but the system processor speed rules always override the DIMM capabilitiesIf you do mix DIMM sp

Strona 30

Standard memory plus optional memory (1 CPU model)Standard memory plus optional memory (1 CPU model)Standard memory plus optional memory (1 CPU model

Strona 31

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 2GB DIMM2D; empty3A; 2GB DIMM3A; em

Strona 32

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 2GB DIMM2D; 2GB DIMM3A; 2GB DIMM3A;

Strona 33

NOTE:NOTE:NOTE:NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailedmemory configuration rules and guidelines, please use the On

Strona 34

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Strona 35

1-88 x SFF SAS Hot Pluggable Hard Drive Bays. OpticalMedia Bay not available for this configuration1-44 x SFF SAS Hot Pluggable Hard DrivesAOptical Me

Strona 36

72GB 3G SAS 15K DPSAS Hot Plug SFF (2.5-inch) Midline (MDL) DrivesSAS Hot Plug SFF (2.5-inch) Midline (MDL) DrivesSAS Hot Plug SFF (2.5-inch) Midline

Strona 37

External StorageExternal StorageExternal StorageExternal Storage QuantityQuantityQuantityQuantitySupportedSupportedSupportedSupportedPositionPositionP

Strona 38

HP StorageWorks SASHP StorageWorks SASHP StorageWorks SASHP StorageWorks SASTape DrivesTape DrivesTape DrivesTape DrivesDAT 160DAT 320LTO-2 Ultrium 44

Strona 39

HP StorageWorks D2DHP StorageWorks D2DHP StorageWorks D2DHP StorageWorks D2DBackup Systems, iSCSIBackup Systems, iSCSIBackup Systems, iSCSIBackup Syst

Strona 40

HP 460W Power SupplyHP 460W Power SupplyHP 460W Power SupplyHP 460W Power SupplyPart Number - AC 460W PSUPart Number - AC 460W PSUPart Number - AC 460

Strona 41

HP 1200W Power SupplyHP 1200W Power SupplyHP 1200W Power SupplyHP 1200W Power SupplyPart Number - AC1200W PSUPart Number - AC1200W PSUPart Number - AC

Strona 42

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (H x W x D)(with bezel)1.70 x 16.78 x 27.25 in (4.32 x 42.62 x 69

Strona 43

Non-operating5 to 95% relative humidity (Rh), 38.7° C (101.7°F) maximum wet bulb temperature, non-condensing.AltitudeAltitudeAltitudeAltitudeOperating

Strona 44

NOTE:NOTE:NOTE:NOTE: Product conformance to cited product specifications is based onsample (type) testing, evaluation, or assessment. This product or

Strona 45

Memory ProtectionMemory ProtectionMemory ProtectionMemory ProtectionAdvanced ECC (multi-bit error protection)Online Spare mode (available with Intel X

Strona 46

Directory Support ServicesDirectory Support ServicesDirectory Support ServicesDirectory Support ServicesActive Directory v1.0 (Windows 2003)Driver Sup

Strona 47

Embedded NC382i DualEmbedded NC382i DualEmbedded NC382i DualEmbedded NC382i DualPort Multifunction GigabitPort Multifunction GigabitPort Multifunction

Strona 48

© Copyright 2010 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Intel, the Intel logo,

Strona 49

Expansion SlotsExpansion SlotsExpansion SlotsExpansion Slots Expansion SlotsExpansion SlotsExpansion SlotsExpansion Slots####TechnologyTechnologyTechn

Strona 50

InterfacesInterfacesInterfacesInterfacesSerial1Video1Network RJ-454iLO 3 remote RJ-45management port1SD slot1 Internal secureUSB 2.0 Ports4 total: 2 r

Strona 51

in-hand with HP Systems Insight Manager, Insight Control suites, and InsightDynamics for ProLiant, helping customers unleash the value of the ProLiant

Strona 52

SecuritySecuritySecuritySecurityPower-on passwordKeyboard passwordQuickLock, Network Server ModeSerial interface controlAdministrator's passwordi