The HP ProLiant DL360 G7 combines performance, intelligent power and cooling management with IT management tools and essential
fault tolerance, all optimized for space constrained installations. A 1U server with the improved performance of the latest Intel 5600
series processors, Unique HP Thermal Logic Technologies that provide leadership in energy efficiencies and ProLiant iLO 3 remote
management. HP continues to provide more performance, flexibility and efficiency for space constrained environments.
Front View:
Rear View:
1.
Hood Cover
1.
PCI Express expansion slot 1, low profile
2.
Up to two Intel processors
2.
PCI Express expansion slot 2 full-height full-length x16 (16,
8, 4, 2, 1), 75W +EXT 75W (option for PCI-X card only support)
3.
Video connector
3.
Power supply bay 1 (populated)
4.
Slide-out System Insight Display (SID)
4.
Power supply bay 2
5.
Removable fan modules for easy serviceability
5.
iLO 3 NIC connector
6.
Eighteen DIMM slots: DDR3 Registered (RDIMM) or
Unbuffered (UDIMM) memory
6.
Serial connector
7.
Video connector
7.
Redundant Hot Plug Power Supplies (upgradeable option)
8.
NIC 4 connector
8.
2 PCI-E Slots
9.
NIC 3 connector
10.
NIC 2 connector
11.
NIC 1 connector
12.
USB connector
13.
USB connector
What's New
Support for new HP hard drives, UPS
QuickSpecs
HP ProLiant DL360 Generation 7 (G7)
Overview
DA - 13598 North America — Version 53 — September 24, 2012
Page 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 55 56

Podsumowanie treści

Strona 1 - QuickSpecs

The HP ProLiant DL360 G7 combines performance, intelligent power and cooling management with IT management tools and essentialfault tolerance, all opt

Strona 2

High PerformanceClustersHP Cluster PlatformsHP Cluster Platforms are specifically engineered, factory-integrated large-scale ProLiant clusters optimiz

Strona 3

Service and SupportHP Technology Services for Industry Standard Servers and BladeSystemCapitalizing on HP ProLiant server and HP BladeSystem capabilit

Strona 4

3-Year HP 6 hour Hardware Support Onsite Call-to-Repair ServiceProvides an IT manager with a team of support specialists who will quickly begin troubl

Strona 5

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - FactoryIntegrat

Strona 6

Base ModelsSix-Core ModelsHP ProLiant DL360 G7E5649 1P 6GB-RP410i/256 4 SFF 460WRPS Server633776-001HP ProLiant DL360 G7E5645 1P 6GB-RP410i/256 4 SFF

Strona 7

Efficiency ModelsQuad-Core ModelsHP ProLiant DL360 G7L5630 1P 4GB-U P410i/ZM4 SFF 460W PS EfficiencyServer579242-001Processor(s)(1) Intel® Xeon® L5630

Strona 8

HP DL360 G7 E5606 USSvr/S-Buy640010-005Processor(s)(1) Intel® Xeon® E5606 (2.13GHz/4-core/4MB/80WMemory4GB (1x 4GB) PC3-10600R (DDR3-1333) Registered

Strona 9

HP DL360 G7 X5660 USSvr/S-Buy640012-005Processor(s)(2) Intel® Xeon® X5660 (2.80GHz/6-core/12MB/95W)Memory8GB (2x 4GB) PC3-10600R (DDR3-1333) Registere

Strona 10

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm

Strona 11

Turbo Boost Technology, with 4,3,2 and 1 cores active.NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memoryspeed may depend on

Strona 12

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - FactoryIntegrat

Strona 13

HP 460W Common Slot Platinum Hot Plug Power Supply Kit593188-B21HP 750W Common Slot Gold Hot Plug Power Supply Kit512327-B21HP 750W Common Slot Platin

Strona 14

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi

Strona 15

HP MemoryRegistered DIMMs (RDIMMs)HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit500656-B21HP S-Buy 2GB (1x2GB) Dual Ran

Strona 16

HP Drive Cage OptionsHP DL360 G6/G7 Small Form Factor Hard Drive Backplane KitNOTE: For 4 addition HD Bays, slots 5-8. This option will work on both D

Strona 17

RECOMMENDATION: For best performance of SSD drives it is recommended that anySmart Array Controller use a max of 4 drives. For this product a second S

Strona 18

HP InfiniBandQLogic InfiniBand 4X QDR PCI-E G2 Dual Port HCA583211-B21HP InfiniBand 4X QDR ConnectX-2 PCIe G2 Dual Port HCA592520-B21HP InfiniBand 4X

Strona 19

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi

Strona 20

NOTE: This license allows 1 server to be deployed and managed via HP iLO Advanced.Customer will receive a printed license entitlement certificate via

Strona 21

NOTE: For additional license kits please see the QuickSpecs at:http://h18004.www1.hp.com/products/quickspecs/13485_na/13485_na.html HP I/O Accelerator

Strona 22

Smart Array P411 Controller HP Smart Array P411/256 2-ports Ext PCIe x8 SAS Controller462830-B21HP Smart Array P411/512 BBWC 2-ports Ext PCIe x8 SAS C

Strona 23

UpgradeabilityUpgradeable to two processorsMemory ProtectionAdvanced ECC (multi-bit error protection)Online Spare mode (available with Intel Xeon 5600

Strona 24

HP Modular Smart Array SC08e 2-ports Ext PCIe x8 SAS Host Bus AdapterNOTE: This is a 2 x4 External Port HBANOTE: This is only approved for the HP Stor

Strona 25

HP 1U Ultrium 1760 SAS ROHS2 Rkmt KitEH946CHP LTO-5 Ultrium 3000 SAS Tape Drive in 1U RackmountNOTE: Connection using HP Smart Array P212/Zero Memory

Strona 26

HP Storage OptionsStorage Fibre Channel HBA NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows andLinux. For detailed co

Strona 27

HP Uninterruptible PowerSystemsHP Rack-mountable UPS HP R1500 G3 Uninterruptible Power Supply (UPS) HP R1.5kVA G3 1U NA Uninterruptible Power SystemAF

Strona 28

HP 8.3kVA 40A High Voltage NA/JP Modular Power Distribution Unit252663-D73NOTE: For additional information on HP Power Distribution Units including ac

Strona 29

must be a minimum of 2.75 inches (7 cm).CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces inthe rack. This arrangem

Strona 30

HP USB and SD OptionsHP USB 04 Standard KeyboardDT528A#ABAHP 4GB Secure Digital High Capacity Flash Media KitNOTE: Blank SD media device is supported

Strona 31

NOTE: Memory configurations listed do not apply to "Factory Integrated Models".DDR3 memory population guidelinesFor detailed memory configur

Strona 32

72 36 72 144 144 288 48 192 384 12 24 48 POPULATED DIMM SPEED (MHz)1 DIMM Per Channel1333 1333 1333 1066 1333 1333 1066 1066 1066 1333 1333 13332 DI

Strona 33

CPU1 CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; empty2D; empty3A; 2GB DIMM3A; empty Chnl 24H; emp

Strona 34

Expansion Slots Expansion Slots#TechnologyBusWidth*ConnectorWidthForm FactorNotes1PCI-ex8 x8Low profile slot2PCI-ex16 x16Full-length, full-height slot

Strona 35

CPU1 CPU2 slot #population orderslot #population order Chnl 11G; 8GB DIMM1G; emptyChnl 12D; 8GB DIMM2D; empty3A; 8GB DIMM3A; empty Chnl 24

Strona 36

CPU1 CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 32GB DIMM2D; 32GB DIMM3A; 32GB DIMM3A; 32GB DIMM

Strona 37

Following are memory options available from HP:HP MemoryRegistered DIMMs (RDIMMs) HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9

Strona 38

NOTE: PC3L is a low voltage memory.QuickSpecsHP ProLiant DL360 Generation 7 (G7)MemoryDA - 13598 North America — Version 53 — September 24, 2012Page

Strona 39

1-88 x SFF SAS Hot Pluggable Hard Drive Bays. Optical MediaBay not available for this configuration1-44 x SFF SAS Hot Pluggable Hard DrivesAOptical Me

Strona 40

72GB 6G SAS 15KSAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives QuantitySupportedPositionSupportedController1TB 6G SAS 7.2K500GB 6G SAS 7.2K81-8HP Sma

Strona 41

External Storage QuantitySupportedPositionSupportedHost Controller or Adapter70 Modular Smart ArrayUp to 2ExternalHP Smart Array P212/256 MB Controlle

Strona 42

HP SAS Tape DrivesDAT 160DAT 320LTO-2 Ultrium 448LTO-3 Ultrium 920LTO-4 Ultrium 1760LTO-4 Ultrium 1840LTO-5 Ultrium 3000LTO-5 Ultrium 32801U Rack-Moun

Strona 43

HP D2D Backup Systems,iSCSID2D2500iD2D4000iExternalEmbedded Network Controller. If the server requires a hardwareiSCSI initiator, the QLogic QLA4050 H

Strona 44

HP 460W Common Slot Gold Hot Plug Power Supply KitPart Number503296-B21Input Voltage Range ( V rms )100 to 240Frequency Range (Nominal) ( Hz )50/60Nom

Strona 45

InterfacesSerial1Video1Network RJ-454iLO 3 remote RJ-45management port1SD slot1 Internal secureUSB 2.0 Ports4 total: 2 rear, 1 front, 1 internal (secu

Strona 46

HP 750W Common Slot Gold Hot Plug Power Supply KitPart Number512327-B21Input Voltage Range ( V rms )100 to 240Frequency Range (Nominal) ( Hz )50/60Nom

Strona 47

HP 1200W Common Slot Silver Hot Plug Power Supply KitPart Number500172-B21Input Voltage Range ( V rms )100 to 240Frequency Range (Nominal) ( Hz )50/60

Strona 48

System UnitDimensions (H x W x D)(with bezel)1.70 x 16.78 x 27.25 in (4.32 x 42.62 x 69.22 cm)Weight(approximate)Maximum(all hard drives, powersupplie

Strona 49

AltitudeOperating3050 m (10,000 ft). This value may be limited bythe type and number of options installed.Maximum allowable altitude change rate is 45

Strona 50

(iLO 3)integrated on systemboardProcessorPCI Express RISC processor core running at 250MHzUpgradeabilityOption firmware upgradeable via Flash ROM.Vide

Strona 51

Smart Array P410iControllerDimensionsEmbeddedDisk Drive and EnclosureInterface - Transfer rate6Gb/s SAS (Serial Attached SCSI)3Gb/s SATA (Serial ATA)S

Strona 52

ConnectorTwo RJ-45Cable Support10Base-TCategories 3, 4 or 5 UTP; up to 328 ft (100 m)100Base-TXCategory 5 or higher UTP; up to 328 ft (100 m)1000BaseT

Strona 53

HP's -48VDC power supply is designed for those environments that require DC Voltage to operate. Thispower supply supplies up to 1200Watts of powe

Strona 54

typically coinciding with new HP server hardware launches. By enablingfirmware to be updated online and integrating firmware and system softwareupdate

Strona 55

www.hp.com/go/spp/downloadHP Integrated Lights-Out 3(iLO 3)HP Integrated Lights-Out 3 (iLO) simplifies server setup, health monitoring,power and therm

Strona 56

HP Insight managementsoftwareHP Insight ControlHP Insight Control, a product option, delivers essential infrastructuremanagement that can help save ti