Chapter 4 - Configuring the Array
74
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
Formatting the Memory Array
Note: The array is formatted to 65% usable capacity at the factory and can
be used without change.
To change the format of the Memory Array:
1. Log into the Memory Array.
2. At the root CLI prompt, type:
Where:
Higher usable percentages provide more usable capacity where needed. Lower
usable percentages increase system write performance, endurance, and
reliability. For advice on selecting a good usable percentage, consult with HP
Customer Support.
format flash-capacity [<value>]
value Specifies the percentage of usable flash capacity. Valid values
are:
50
65
78
84
87
90 — Not recommended for high performance or high reliability
systems.
Default is 65%.