Page 16-7
Press
@@@OK@@@
to obtain the following results:
Confidence intervals
The application 6. Conf Interval can be accessed by using ‚Ù—
@@@OK@@@
. The application offers the following options:
These options are to be interpreted as follows:
1. Z-INT: 1 µ.: Single sample confidence interval for the population mean, µ,
with known population variance, or for large samples with unknown
population variance.
2. Z-INT: µ1µ2.: Confidence interval for the difference of the population
means, µ
1
- µ
2
, with either known population variances, or for large
samples with unknown population variances.
3. Z-INT: 1 p.: Single sample confidence interval for the proportion, p, for
large samples with unknown population variance.
4. Z-INT: p1− p2.: Confidence interval for the difference of two proportions,
p
1
-p
2
, for large samples with unknown population variances.