HP Virtual Connect Manager Command Line Interface User Guide Version 1.20 Part Number 449298-001 September 2007 (First Edition)

Strona 2 - Audience assumptions

Command line 10 Managed element Description ldap-group (on page 21) Manage LDAP group configuration settings mac-cache (on page 22) Manage Ethernet

Strona 3 - Contents

Command line 11 Supported actions: delete, help, set, show Item Description delete domain Delete the existing Virtual Connect domain configuration.

Strona 4 - Contents 4

Command line 12 Item Description WwnPool The pre-defined WWN pool to use for address assignment. Valid values include integers 1-64. This property i

Strona 5 - Introduction

Command line 13 Item Description Syntax import enclosure UserName=<username> Password=<password> The password field is optional on the c

Strona 6 - Command line syntax

Command line 14 Item Description PXE Enables or disabled PXE on the network connection. Valid values are enabled, disabled, and UseBios. If this val

Strona 7 - CLI command execution modes

Command line 15 Item Description PXE Enables or disables PXE on a connection. Valid values are enabled, disabled, and UseBios. Applies to Ethernet n

Strona 8

Command line 16 Item Description Examples: ->set external-manager UserName=steve Enabled=false Disables the external manager ->set externa

Strona 9 - Command line

Command line 17 fc-connection Manage Fibre Channel SAN fabric connections. Supported actions: add, help, set Item Description add fc-connection Add

Strona 10

Command line 18 Item Description Syntax set fc-connection <ProfileName> <Port> [Fabric=<FabricName>] [Speed=<Auto|2Gb|4Gb|Disab

Strona 11 - Item Description

Command line 19 Item Description update firmware Update the firmware on all Virtual Connect modules in the domain Syntax update firmware url=<fi

Strona 12

© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Strona 13

Command line 20 Item Description ->remove interconnect enc0:2 Removes a specific interconnect module (bay 2) from the domain ->remove interc

Strona 14

Command line 21 Item Description LocalUsers Enables or disables local user authentication. Valid values include "Enabled" and "Disabl

Strona 15

Command line 22 Item Description set ldap-group Modify the properties of an existing directory group Syntax set ldap-group <GroupName> [Descr

Strona 16

Command line 23 network Manage Virtual Connect Ethernet networks. Supported actions: add, help, remove, set, show Item Description add network Crea

Strona 17

Command line 24 Item Description Parameters: NetworkName The name of an existing network to modify Properties: Name The new name of the network S

Strona 18

Command line 25 Item Description Examples: ->add profile MyNewProfile Creates a new profile and adds it to the domain, using default connection

Strona 19

Command line 26 Item Description show profile Display all server profiles that exist in the domain Syntax show profile [<ProfileName> | *] Ex

Strona 20

Command line 27 Item Description ->poweroff server enc0:2 Shuts down a specific server in device bay 2 of an enclosure with ID enc0 ->powero

Strona 21

Command line 28 Item Description ForceOnTimeout Attempts a graceful power down, but if the server does not shutdown within the timeout period (defau

Strona 22

Command line 29 status View overall domain status information. Supported actions: help, show Item Description show status Display the status of the

Strona 23

Contents 3 Contents Introduction...

Strona 24 - Manage server profiles

Command line 30 Item Description ->add uplinkport enc0:1:1 Network=MyNetwork Adds a new uplink port (Bay 1, Port 1) to a network ->add upli

Strona 25

Command line 31 Item Description ->set uplinkport enc0:2:1 Network=MyNetwork Speed=Disabled Disables a specific port that belongs to a network

Strona 26

Command line 32 Item Description show uplinkset Display shared uplink configurations Syntax show uplinkset [<UplinkSetName> | *] Examples:

Strona 27

Command line 33 Item Description ->remove user steve Removes a specific user by name ->remove user * Removes all users Item Description se

Strona 28

Command line 34 Item Description ->show user steve Displays details of an existing user by name ->show user * Displays details of all existi

Strona 29

Command line 35 . . . • Subcommand help—displays help details associated with a specific subcommand, including supported managed elements: >assi

Strona 30

Command line 36 ->show device bay * - Show detailed information for a specific device bay 2 of a specific enclosure: ->show dev

Strona 31

Command line 37 brad domain Brad Mills [email protected] true server -----------------------------------

Strona 32

Command line 38 UserName : alice Privileges : storage FullName : Alice Candle ContactInfo : [email protected] Enabled : false Scripta

Strona 33

Command line 39 Example 3: Scriptable output format displaying all users (with table header) ->show user -output=script2 UserName;Privileges;Full

Strona 34 - Help subsystem

Contents 4 Fibre Channel setup...

Strona 35 - Command line 35

Configuring the Virtual Connect domain using the CLI 40 Configuring the Virtual Connect domain using the CLI Basic configuration A Virtual Connect d

Strona 36 - Output format

Configuring the Virtual Connect domain using the CLI 41 password: <Default Administrator login credentials> • LDAP Authentication >ssh 192

Strona 37 - Command line 37

Configuring the Virtual Connect domain using the CLI 42 >add user bob password=fhkjdhfk privileges=domain,network • Modify an existing user >

Strona 38 - Scriptable output format

Configuring the Virtual Connect domain using the CLI 43 It is possible to create a user with no privileges. This user can only view status and setti

Strona 39 - Command line 39

Configuring the Virtual Connect domain using the CLI 44 override the factory default MAC addresses while the server remains in that Virtual Connect

Strona 40 - Basic configuration

Configuring the Virtual Connect domain using the CLI 45 Creating an enet-network To create a new Ethernet network use the add network command: >a

Strona 41 - Domain setup

Configuring the Virtual Connect domain using the CLI 46 Because VLAN tags are added or removed when Ethernet packets leave or enter the VC-Enet shar

Strona 42

Configuring the Virtual Connect domain using the CLI 47 accessing the physical FC HBA through the enclosure Onboard Administrator and the iLO interf

Strona 43 - Network setup

Configuring the Virtual Connect domain using the CLI 48 Virtual Connect v1.20 adds the ability to configure PXE settings when using either VC Assign

Strona 44

Configuring the Virtual Connect domain using the CLI 49 If a server blade is inserted into a device bay already assigned a server profile, Virtual C

Strona 45 - Creating an enet-network

Introduction 5 Introduction Virtual Connect overview Virtual Connect is a set of interconnect modules and embedded software for HP BladeSystem c-Clas

Strona 46 - Fibre Channel setup

Configuring the Virtual Connect domain using the CLI 50 IGMP allows VC-Enet modules to monitor (snoop) the IP multicast membership activities and to

Strona 47 - Server Profile setup

Configuring the Virtual Connect domain using the CLI 51 Operation Examples Display stacking link configuration and status >show stackinglink Disp

Strona 48

Configuring the Virtual Connect domain using the CLI 52 alternate Virtual Connect Ethernet module. This feature can be useful when troubleshooting t

Strona 49 - Configuring IGMP settings

Technical support 53 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical su

Strona 50 - Common management operations

Acronyms and abbreviations 54 Acronyms and abbreviations BIOS Basic Input/Output System CLI Command Line Interface DHCP Dynamic Host Configuration

Strona 51

Acronyms and abbreviations 55 PXE Preboot Execution Environment SAN storage area network SSH Secure Shell VCM Virtual Connect Manager WWN World

Strona 52

Index 56 A authorized reseller 53 B basic configuration 40 C CLI command execution modes 7 command line overview 5 command line syntax 6 co

Strona 53 - Technical support

Index 57 R remote access 8 resetting Virtual Connect Manager 51 S scriptable output format 38 server command 26 server profile, assigning to

Strona 54 - Acronyms and abbreviations

Introduction 6 • When no browser is available or you prefer to use a command line interface, you can access management data and perform configuratio

Strona 55

Introduction 7 output option requires an argument, which is a list of one or more output format attributes. However, the -quiet option does not requi

Strona 56 - Index 56

Introduction 8 -> Non-Interactive Mode In some cases, users might want to write automated scripts that execute a single command at a time. These

Strona 57 - Index 57

Command line 9 Command line Subcommands Command Description add Add a new object to the domain or to another object assign Assign a server profile