Hp Insight Management-Software Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie Hp Insight Management-Software. HP Insight Management-Software User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
HP Insight Management Virtual Connect
Enterprise Manager
Command Line Interface Version 7.0 User Guide
Abstract
This user guide is intended for Virtual Connect administrators who are familiar with both Virtual Connect and with the Virtual
Connect management suite including Virtual Connect Manager, Virtual Connect Enterprise Manager and upper level managers
such as HP Logical Storage Manager and HP Matrix Operating Environment.
HP Part Number: 656831-003
Published: February 2012
Edition: 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 95 96

Podsumowanie treści

Strona 1 - Enterprise Manager

HP Insight Management Virtual ConnectEnterprise ManagerCommand Line Interface Version 7.0 User GuideAbstractThis user guide is intended for Virtual Co

Strona 2

)echo Assign the profiles to bays that have servers present ---------------------------------for /L %%I in (1,1,%MAXPROFILES%) DO ( ::Turn off the

Strona 3 - Contents

Role based Access Control (RBAC)Role based access control allows you to designate which operations and resources can bemanipulated.RBAC DetailsVCEM pr

Strona 4 - 4 Contents

Table 2 RBAC privileges (continued)VCEM User(read only)VCEMGroupLimitedOperatorVCEMGroupOperatorVCEMGroupAdministratorVCEMAdministratorCommand line op

Strona 5 - 1 Getting Started

Working with server profilesVCEMCLI provides the most commonly used profile operations including:• Server profile creation or update• Server profile a

Strona 6 - Initiating multiple commands

• Select from the following Flex-10 iSCSI network connection options:Add Flex-10 iSCSI network connections using the -add iscsi-connection command.◦◦

Strona 7

Displaying job detailsThe –show job -jobid command displays detail for the specified VCEM job. The commandreturns a value corresponding to the current

Strona 8 - 2 Using VCEMCLI

Accessing VCEMCLI helpHelp is obtained by running VCEMCLI without any arguments.GETTING STARTED:-help : displays a list of available commands and mana

Strona 9 - Using VCEMCLI in a script

------------------------------------------------------------------Managed Elements------------------------------------------------------------------de

Strona 10 - Session Lifetime

3 Using VCEM commandsThis chapter describes VCEMCLI commands .add profileThe -add profile command creates a profile from the supplied server profile d

Strona 11 - RBAC Details

Minimum Required Role Based SecurityVCEM Group AdministratorRemarksThis command creates a new unassigned server profile.VCEM fills empty attributes wi

Strona 12 - RBAC Best Practices

© Copyright 2011, 2012 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or

Strona 13 - Working with server profiles

set profileThe -set profile command modifies the properties on an existing server profile.Syntax-set profile -profilename <profileName>[-name &l

Strona 14 - 14 Using VCEMCLI

assign profileThe -assign profile command assigns the profile identified by the ProfileName to the bayspecified by the BayName.Syntax-assign profile –

Strona 15 - Displaying job details

The system page in HP Systems Insight Manager provides the enclosure name as displayed circledin red in Figure 1 (page 22).Figure 1 Enclosure nameThe

Strona 16 - Accessing VCEMCLI help

export profilesThe -export profiles command exports server profiles to a CSV file for use with externaltools.Syntax-export profiles –exportfile testfi

Strona 17 - Error Reporting

unassign profileThe -unassign profile command unassigns the selected server profile.Syntax-unassign profile -profilename <profileName>Parameters

Strona 18 - 3 Using VCEM commands

add enet-connectionThe -add enet-connection command is used to add a new Ethernet network connection toan existing server profile in the VC Domain.NOT

Strona 19 - Server profile prerequisites

Table 8 Parameter descriptions for -Add enet-connection (continued)OptionalRequiredDescriptionParameterxThe requested operationalspeed for the server

Strona 20

• Add a new Ethernet network connection and set the speed to Preferred:vcemcli -add enet-connection –profilename MyProfile –networkMyNetwork –SpeedTyp

Strona 21

set enet-connectionThe -set enet-connection command modifies an Ethernet connection of a server profile.Syntax-set enet-connection –profilename <pr

Strona 22 - Prerequisites

Table 9 Parameter descriptions for -set enet-connection (continued)OptionalRequiredDescriptionParameterxThe requested operationalspeed for the server

Strona 23 - Examples

Contents1 Getting Started...5VCEMCLI Prerequisites...

Strona 24

• Modify Ethernet network connection to set the speed to preferred:vcemcli -set enet-connection –profilename MyProfile1 -portnumber 1–speedtype prefer

Strona 25

remove enet-connectionThe -remove enet-connection command removes the last Ethernet network connection froman existing server profile.Syntax-remove en

Strona 26

add fc-connectionThe -add fc-connection command adds a new FC connection to a server profile.Syntax-add fc-connection –profilename <profileName>

Strona 27

Minimum Required Role Based SecurityVCEM Group OperatorRemarksThe job status for the jobid can be obtained by executing VCEMCLI with the –show job com

Strona 28

set fc-connectionThe -set fc-connection command modifies an existing FC connection to a server profile.Syntax-set fc-connection –profilename <prof

Strona 29

Table 12 Parameter descriptions for -set fc-connection (continued)OptionalRequiredDescriptionParameterxIMPORTANT: The-bootport parameter isonly requir

Strona 30 - 30 Using VCEM commands

remove fc-connectionThe -remove fc-connection command removes the last FC connection from a server profile.Syntax-remove fc-connection –profilename &

Strona 31

add fcoe-connectionThe -add fcoe-connection command adds a new FCoE connection to a server profileSyntax-add fcoe-connection –profilename <profileN

Strona 32

• Add a new FCoE connection and leave it unassigned:vcemcli -add fcoe-connection MyNewProfile -connectionbay 3• Add a new FCoE connection and set the

Strona 33 - User Guide

set fcoe-connectionThe -set fcoe-connection command modifies an existing FCoE connection.Syntaxset fcoe-connection –profilename <profileName>

Strona 34

remove fcoe-connection...41add iscsi-connectio

Strona 35

Table 15 Parameter descriptions for -set fcoe-connection (continued)OptionalRequiredDescriptionParameter• secondary• disabledOnly one boot parameter i

Strona 36

remove fcoe-connectionThe -remove fcoe-connection command removes the last FCoE connection from an existingserver profile.Syntax-remove fcoe-connectio

Strona 37

add iscsi-connectionThe -add iscsi-connection command adds a new iSCSI connection to an existing VC serverprofile.NOTE: The -add iscsi-connection comm

Strona 38 - 38 Using VCEM commands

Table 17 Parameter descriptions for -add iscsi-connection (continued)OptionalRequiredDescriptionParametervalue is 100Mb to themaximum.OutputThe functi

Strona 39

set iscsi-connectionThe –set iscsi-connection command modifies the properties of a specified iSCSI connection.Syntax-set iscsi-connection –profilename

Strona 40

OutputThe function returns the result of the set operation or a jobid if –nb is specified.Examples• Change the network to a different one:vcemcli -set

Strona 41

remove iscsi-connectionThe remove iscsi-connection command removes the highest numbered iSCSI connectionfrom the server VC profile. If no connections

Strona 42

set iscsi-boot-paramThe -set iscsi-boot-param command configures the basic iSCSI boot parameters on thespecified iSCSI connection.Syntax-set iscsi-boo

Strona 43

Table 20 Parameter descriptions for -set iscsi-boot-param (continued)OptionalRequiredDescriptionParameterxNOTE: The-initiatornameparameter is required

Strona 44

Table 20 Parameter descriptions for -set iscsi-boot-param (continued)OptionalRequiredDescriptionParameterxNOTE: The-targetport2 parameteris required i

Strona 45

1 Getting StartedThe VCEM Command Line is a family of executables that provide the facilities necessary for themost frequently used management operati

Strona 46

Table 20 Parameter descriptions for -set iscsi-boot-param (continued)OptionalRequiredDescriptionParameterxAllows the iSCSI optionROM to retrieve the T

Strona 47

remove iscsi-boot-paramThe –remove iscsi-boot-param command removes all the iSCSI boot parameters configuredon the specified iSCSI connection.Syntax-r

Strona 48

add server-port-mapThe -add server-port-map command adds new server port network mapping, and allowsserver ports to be shared among multiple VC Ethern

Strona 49

OutputThe function returns the result of the add operation or a jobid if –nb is specified.Examples• Add a new server port to dedicated network mapping

Strona 50

set server-port-mapThe -set server-port-map command modifies the properties of a server port network mapping.Syntax-set server-port-map –profilename &

Strona 51

Examples• Modify the VLAN ID of an existing server port network mapping:vcemcli -set server-port-map –profilename MyProfile –portnumber 1–network Netw

Strona 52

remove server-port-mapThe –remove server-port-map command removes server port network mapping.NOTE: The –remove server-port-map command cannot be used

Strona 53

poweroff devicebayThe -poweroff devicebay command sends a power-off request to Virtual Connect Managerfor a given bay.Syntax-poweroff devicebay –enclo

Strona 54

• Normal power off operation on device bay 2 of an enclosure with ID enc0, if the timeoutoccurs, then the system is forced into power off.vcemcli -pow

Strona 55

poweron devicebayThe -poweron devicebay command sends a power-on request to Virtual Connect Manager fora given bay.Syntax-poweron devicebay -enclosure

Strona 56

• Run scripts in response to Systems Insight Manager events or from the Windows job scheduler.• Leverage the CSV export of profile data to answer ques

Strona 57

show power-statusThe -show power-status command displays the power status of the indicated bay.Syntax-show power-status -enclosurename <enclosurena

Strona 58

show jobThe -show job command reports the status of the indicated job.Syntax-show job –jobid <jobNumber>ParametersTable 28 Parameter description

Strona 59

show versionThe -show version command displays version information for the VCEM server.Syntax-show version ParametersNoneOutputThe -show version comma

Strona 60

show vcem-statusThe -show vcem-status command displays the VCEM management status for the specified VCDomain.Syntax-show vcem-status-domainname<Dom

Strona 61

startvcdmaintThe -startvcdmaint command starts the VC domain maintenance operation on the specifiedVC domain. For more information on what VCM operati

Strona 62

cancelvcdmaintThe -cancelvcdmaint command cancels the VC domain maintenance operation on the specifiedVC domain.Syntax-cancelvcdmaint <DomainName&g

Strona 63

completevcdmaintThe -completevcdmaint command completes the VC domain maintenance operation on thespecified VC domain propagating changes across all d

Strona 64

4 Error messagesTo help you troubleshoot symptoms, Table 35 and Table 36 (page 68) displays error messagenumbers and descriptions.Table 35 VCEMCLI err

Strona 65

Table 35 VCEMCLI error messages and descriptions (continued)Error message descriptionError message numberFailed to initialize XML parser124Failed to c

Strona 66

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 67 - 4 Error messages

Security on the CMSVCEMCLI is installed on the CMS. By installing on the CMS, you get the benefits of the securitymeasures already in place for the CM

Strona 68

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 69

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 70

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 71

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 72

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 73

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 74

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 75

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 76

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 77

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 78

2 Using VCEMCLIVCEMCLI can be executed from the Windows command line or from scripts written in anyWindows-supported scripting language.ExecutableThe

Strona 79

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 80

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 81

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 82

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 83

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 84

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 85

Table 36 VCEM server error messages and descriptions (continued)Error message descriptionNOTE: The error message descriptions in this table use[x] to

Strona 86

5 Troubleshooting VCEMCLIVCEMCLI calls result in access denied errorsTo resolve access denied errors, verify that the credentials used with the VCEMCL

Strona 87 - 5 Troubleshooting VCEMCLI

Unable to assign a profile to a Domain GroupIf the profile is not the same configuration as the VC Domain Group, then you might not be ableto assign t

Strona 88 - 88 Troubleshooting VCEMCLI

For more information about supported Virtual Connect firmware, go to http://www.hp.com/go/vcem.Creating a server profile failsAttempting to create a p

Strona 89

Table 1 Common options (continued)DescriptionCLI optionsNOTE: When using this option, it is possible thatsequential edits queued for the same profile

Strona 90 - 90 Troubleshooting VCEMCLI

As a result, VCEM APIs can report false job results such as, Completed with success, eventhough the server profile changes have not taken effect. The

Strona 91

following error message appears whenever an -add profile or -set profile operation isperformed and there is one or more server profiles inside the VC

Strona 92 - 6 Support and other resources

6 Support and other resourcesBefore you contact HPBe sure to have the following information available before you call contact HP:• Technical support r

Strona 93 - Related information

Registering for software technical support and update serviceInsight Management includes one year of 24 x 7 HP Software Technical Support and UpdateSe

Strona 94 - Typographic conventions

For more information about Virtual Connect Manager, see:• BladeSystem c-Class Solution Overview• HP Virtual Connect for c-Class BladeSystem User Guide

Strona 95

IndexAadd enet-connectioncommand, 25add fc-connectioncommand, 32add fcoe-connectioncommand, 37add iscsi-connectioncommand, 42add profilecommand, 18add

Strona 96 - 96 Index

remove server-port-mapcommand, 56role based access control, 11Sset enet-connectioncommand, 28set fc-connectioncommand, 34set fcoe-connectioncommand, 3

Komentarze do niniejszej Instrukcji

Brak uwag