Hp Radio Frequency Planner Software Series Instrukcja Użytkownika Strona 115

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 120
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 114
Appendix C: File Level and Application Level Parameters
HP RF Planner User Guide
113
Appendix C: File Level and Application Level Parameters
The following section presents an overview of the File level and the Application level parameters.
Table 1 File Level Parameters
File Level Parameters
Data Type
Default Value
Minimum
Maximum
Accuracy Integer 1 1 4
RSSI Calibration Integer -10 dB -40 dB 40 dB
Spillage Factor Positive Integer 2 2 3
Min Attenuation Factor
Real
2
1.6
4
Max Attenuation Factor
Real
2
1.6
4
Alpha
Real
-4
Not applicable
Not applicable
Beta
Real
0.08
Not applicable
Not applicable
Table 2 Application Level Parameters
Application Level
Parameters
Data Type Default Value Minimum Maximum
Coverage Estimation
Thresholds
Integer
-40, -50, -55, -60
dBm
-100 dBm -10 dBm
Sensor Detection
Threshold
Integer -85 dBm -150 dBm -20 dBm
Sensor Redundancy
Integer
1
1
10
Sensor Prevention
Thresholds
Integer
-65, -60, -55 dBm
(low<medium<high)
-150 dBm -20 dBm
Device Transmit Power Integer 13 0 20
Channel View Threshold Integer -85 dBm -150 dBm -20 dBm
AP Redundancy Integer 1 1 10
In addition to these parameters, Planner also has the following application level parameters:
1 Region Settings in ToolsSettingsPreferencesAP Views
2 Default Access Point Settings
3 Auto Channel Select
4 Do not show this window again messages
5 Color Palettes
6 Report Base Folder
Note: The default installation values are selected when you install a new version of Planner.
Przeglądanie stron 114

Komentarze do niniejszej Instrukcji

Brak uwag