Hp Smart Storage Administrator Instrukcja Użytkownika Strona 111

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 110
Troubleshooting 111
No data is lost when a drive fails, as long as no failed drive is mirrored to another failed drive.
Up to half of the physical drives in the array can fail.
Disadvantages:
This method is expensive, because many drives are needed for fault tolerance.
Only half of the total drive capacity is usable for data storage.
RAID 1 (ADM) and RAID 10 (ADM)
In RAID 1 (ADM) and RAID 10 (ADM) configurations, data is duplicated to two additional drives.
When the array contains only three physical drives, the fault-tolerance method is known as RAID 1 (ADM).
When the array has more than three physical drives, drives are mirrored in trios, and the fault-tolerance
method is known as RAID 10 (ADM).
Przeglądanie stron 110
1 2 ... 106 107 108 109 110 111 112 113 114 115 116 ... 126 127

Komentarze do niniejszej Instrukcji

Brak uwag