NOTE:
Standard and FATA disk drives must be in separate disk groups. Disk drives of different capacities and
spindle speeds can be included in the same disk group, but you may want to consider separating
them into separate disk groups.
CX8167-ST
21
Figure 6 Sequential building of vertical disk groups
1. Disks installed in rst group
2. Disks installed in second group
Adding a disk drive
This section describes the procedure for a dding a Fibre Channel disk drive.
Removi ng the drive blank
1. Grasp the drive blank by the two mounting tabs (see Figure 7).
2. Lift up on the lower mou nting tab and pull the blank out of the enclosure.