Hp 60-Modular-Smart-Array Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Przechowywanie Hp 60-Modular-Smart-Array. HP 60-Modular-Smart-Array User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
HP StorageWorks 60 Modular
Smart Array Enclosure
User Guide
November 2006 (Second Edition)
Part Number 405868-002
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - User Guide

HP StorageWorks 60 Modular Smart Array Enclosure User Guide November 2006 (Second Edition) Part Number 405868-002

Strona 2 - Audience assumptions

Component identification 10 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation On, off, or flashing Alternating amber and bl

Strona 3 - Contents

Operations 11 Operations In this section Power up...

Strona 4 - Contents 4

Operations 12 2. Press the Power On/Standby button on the storage enclosure. Wait for the system power LED to go from green to amber. 3. Disconnect

Strona 5 - Contents 5

Setup 13 Setup In this section Rack planning resources ...

Strona 6 - Component identification

Setup 14 When a vertical space in the rack is not filled by a server or rack component, the gaps between the components cause changes in airflow thro

Strona 7 - Rear panel components

Setup 15 • Do not allow the overall system AC current load to exceed 80 percent of the branch circuit AC current rating. • Do not use common power o

Strona 8 - Rear panel LEDs and buttons

Setup 16 Rack mounting hardware kit contents The rack mounting hardware kit provides the required components for quick deployment in Compaq branded,

Strona 9 - SAS and SATA hard drive LEDs

Setup 17 3. Use a No. 2 Phillips screwdriver to remove the standard pins from the front and back ends of the rail. 4. Install four round-hole pins

Strona 10

Setup 18 NOTE: Identify the left (L) and right (R) rack rails by markings stamped into the sheet metal. 2. Secure the back end of the rails to t

Strona 11 - Operations

Setup 19 If you are installing the storage enclosure into a telco rack, order the appropriate option kit at the RackSolutions website (http://www.rac

Strona 12 - Disconnect the power cords

© Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Strona 13 - Optimum environment

Setup 20 Choosing a configuration Cable procedures vary, depending on the configuration. Choose one of the following configurations. NOTE: The lef

Strona 14 - Power requirements

Setup 21 Cascading (1+1) configuration Item Description 1 MSA60 1* 2 MSA60 2* 3 SAS cable 4 SAS cable 5 Server * Only MSA60 enclosures can be c

Strona 15 - Shipping contents

Setup 22 For a complete list of supported cables, see the QuickSpecs on the HP website (http://www.hp.com). Power cords The power cord should be app

Strona 16

Hardware options installation 23 Hardware options installation In this section Hard drive options ...

Strona 17

Hardware options installation 24 2. Prepare the hard drive. 3. Install the hard drive. IMPORTANT: When the drive is inserted, the drive LEDs fl

Strona 18

Configuration and utilities 25 Configuration and utilities In this section Configuration tools...

Strona 19 - Installing servers

Configuration and utilities 26 For more information regarding array controller configuration, refer to the controller user guide. For more informati

Strona 20 - Choosing a configuration

Configuration and utilities 27 • From within Survey Utility • From within operating system-specific IML viewers • For NetWare: IML Viewer • For W

Strona 21 - Supported cables

Troubleshooting 28 Troubleshooting In this section When the storage enclosure does not start ...

Strona 22 - Updating firmware

Troubleshooting 29 Diagnostic questions Are the power supply/system fan LEDs green? Answer Possible Reasons Possible Solutions No • The power cor

Strona 23 - Hard drive options

Contents 3 Contents Component identification...

Strona 24 - 3. Install the hard drive

Troubleshooting 30 For additional information about diagnosing hard drive problems, see the HP ProLiant Servers Troubleshooting Guide. CAUTION: So

Strona 25 - Configuration and utilities

Troubleshooting 31 • Open HP SIM and inspect the Error Counter window for each physical drive in the same array to confirm that no other drives have

Strona 26 - Diagnostic tools

Troubleshooting 32 • The amount of unused capacity on the drives • The number of drives in the array (for RAID 5 and RAID 6 with ADG) Allow approxim

Strona 27 - Keeping the system current

Troubleshooting 33 Some status messages are available without pressing the F3 key. For example, on the Main menu, the FAILED status appears next to t

Strona 28 - Troubleshooting

Regulatory compliance notices 34 Regulatory compliance notices In this section Regulatory compliance identification numbers ...

Strona 29 - Diagnostic questions

Regulatory compliance notices 35 Class A equipment This equipment has been tested and found to comply with the limits for a Class A digital device,

Strona 30 - Compromised fault tolerance

Regulatory compliance notices 36 Modifications The FCC requires the user to be notified that any changes or modifications made to this device that a

Strona 31 - Time required for a rebuild

Regulatory compliance notices 37 Disposal of waste equipment by users in private households in the European Union This symbol on the product or on

Strona 32

Regulatory compliance notices 38 Korean notice Class A equipment Class B equipment Power cord statement for Japan

Strona 33 - Handling disk drive failures

Electrostatic discharge 39 Electrostatic discharge In this section Preventing electrostatic discharge...

Strona 34 - FCC rating label

Contents 4 Array Diagnostic Utility ...

Strona 35 - FCC logo, United States only

Specifications 40 Specifications In this section Environmental specifications ...

Strona 36 - Modifications

Technical support 41 Technical support In this section Before you contact HP...

Strona 37 - BSMI notice

Technical support 42 • Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged fo

Strona 38 - Korean notice

Technical support 43 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations

Strona 39 - Electrostatic discharge

Technical support 44 CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte Standorte

Strona 40 - Specifications

Technical support 45 Customer Self Repair Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een mi

Strona 41 - Technical support

Technical support 46 Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o pedido. Onde as condiç

Strona 42

Technical support 47

Strona 44 - Technical support 44

Acronyms and abbreviations 49 Acronyms and abbreviations ACU Array Configuration Utility ADG Advanced Data Guarding (also known as RAID 6) ADU Arr

Strona 46 - Technical support 46

Acronyms and abbreviations 50 NFPA National Fire Protection Association ORCA Option ROM Configuration for Arrays OSEM Open Services Event Manager

Strona 47 - Technical support 47

Index 51 A ADU (Array Diagnostic Utility) 27 airflow requirements 13 Array Diagnostic Utility (ADU) 27 authorized reseller 41 B BSMI notice

Strona 48 - Technical support 48

Index 52 O Open Services Event Manager 27 optimum environment 13 Option ROM Configuration for Arrays (ORCA) 25 options installation 23 ORCA (

Strona 49 - Acronyms and abbreviations

Component identification 6 Component identification In this section Front panel LEDs and buttons...

Strona 50

Component identification 7 Rear panel components Item Description 1 Power supply 1 2 Fan module 1 3 Dual 7-segment display board (for box I

Strona 51 - Index 51

Component identification 8 Rear panel LEDs and buttons Item Description Status 1 I/O module LED Green = System activity Amber flashing = Fau

Strona 52 - Index 52

Component identification 9 SAS and SATA device numbers SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online

Komentarze do niniejszej Instrukcji

Brak uwag