Hp SAN Virtualization Services Platform Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Przechowywanie Hp SAN Virtualization Services Platform. HP SAN Virtualization Services Platform User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
HP StorageWorks Virtualization Services
Manager v2 server user guide
This guide provides basic information about the Virtualization Services Manager (VSM) server (version 2) used
with the SAN Virtualization Services Platform (SVSP) solution. This server contains no customer self-repair items.
Any repairs should be performed by HP Services personnel.
Part number: 56970137
First edition: September 2009
Przeglądanie stron 0
1 2 3 4 5 6 ... 71 72

Podsumowanie treści

Strona 1 - Manager v2 server user guide

HP StorageWorks Virtualization ServicesManager v2 server user guideThis guide provides basic information about the Virtualization Services Manager (VS

Strona 2

Rear panel LEDs and buttonsTable 4 Rear panel LEDs and buttonsStatusDescriptionItemGreen = Activity exists.Flashing green = Activity exists.Off = No a

Strona 3 - Contents

StatusDescriptionItemGreen = NormalOff = One or more of the following conditions exists:• AC power unavailable• Power supply failed• Power supply in s

Strona 4

Table 6 HP Systems Insight Display LEDsStatusDescriptionItemTo determine Power cap status, see “System Insight Display LEDcombinations” on page 13.Pow

Strona 5

System Insight Display LED combinationsWhen the health LED on the front panel illuminates either amber or red, the server is experiencing ahealth even

Strona 6

StatusSystem power LEDHealth LEDSystems Insight DisplayLED and colorStandbyAmber—Power cap (off)Waiting for powerFlashing green—Power cap (green)Power

Strona 7 - 1 Component identification

SAS hard drive LEDsTable 8 SAS hard drive LEDsDescriptionItemFault/UID LED (amber/blue)1Online LED (green)2SAS hard drive LED combinationsTable 9 SAS

Strona 8 - Front panel LEDs and buttons

InterpretationFault/UID LED(amber/blue)Online/activityLED (green)CAUTION:Do not remove the drive. Removing a drive may terminatethe current operation

Strona 9 - Rear panel components

2 OperationsPower up the serverTo power up the server, press the Power On/Standby button.Power down the serverWARNING!To reduce the risk of personal i

Strona 10 - Rear panel LEDs and buttons

1. Power down the server (see page 17).2. Disconnect all peripheral cables and power cords.3. Loosen the front panel thumbscrews.4. Extend the server

Strona 11

2. Extend the display from the chassis.The display can be rotated up to 90 degrees.HP StorageWorks Virtualization Services Manager v2 server user guid

Strona 12 - StatusDescriptionItem

Legal and notice information© Copyright 2009 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without no

Strona 13

Operations20

Strona 14 - SAS device numbers

3 SetupRack planning resourcesThe rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 seriesracks. For more information

Strona 15 - SAS hard drive LEDs

The 9000 and 10000 Series Racks provide proper server cooling from flow-through perforations inthe front and rear doors that provide 64 percent open a

Strona 16

WARNING!To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supplybranch circuit that provides power to th

Strona 17 - 2 Operations

Rack warningsWARNING!To reduce the risk of personal injury or damage to the equipment, be sure that:• The leveling jacks are extended to the floor.• T

Strona 18 - Operations18

WARNING!This server is very heavy. To reduce the risk of personal injury or damage to the equipment:• Observe local occupational health and safety req

Strona 19

To configure these utilities manually:• Press the F8 key when prompted during the array controller initialization to configure the arraycontroller usi

Strona 20 - Operations20

4 Software and configuration utilitiesConfiguration toolsSmartStart softwareSmartStart is a collection of software that optimizes single-server setup,

Strona 21 - Rack planning resources

Default configuration settings are sufficient for proper typical server operation, but configurationsettings can be modified using RBSU. The system wi

Strona 22 - Power requirements

• Online Spare Mode—Provides protection against failing or degraded DIMMs. Certain memoryis set aside as spare, and automatic failover to spare memory

Strona 23

Contents1 Component identification ... 7Front panel components ...

Strona 24 - Rack warnings

The utility also provides support for the following functions:• Reconfiguring one or more logical drives• Viewing the current logical drive configurat

Strona 25

System Management driver, also known as the Health Driver, is loaded. When the operating systemis functioning properly, the system periodically resets

Strona 26

HP Systems Insight ManagerHP SIM is a web-based application that allows system administrators to accomplish normaladministrative tasks from any remote

Strona 27 - Configuration tools

The Vulnerability and Patch Management Pack is an all-in-one vulnerability assessment and patchmanagement tool. It enables you to gain the upper hand

Strona 28 - Configuring AMP modes

Using an integrated, wizard-based installer, Insight Control Environment suites install and configureHP Systems Insight Manager (HP SIM) and HP ProLia

Strona 29 - Array Configuration Utility

• DOS• Environments which do not support USB nativelyFor additional security, external USB functionality can be disabled through RBSU.For more informa

Strona 30 - Management tools

Remote support and analysis toolsHP Insight Remote Support softwareHP Insight Remote Support software delivers secure remote support for your HP Serve

Strona 31 - Erase Utility

can be downloaded free of charge from the SmartStart download page on the HP website (http://www.hp.com/go/support).System Online ROM Flash Component

Strona 32 - Management agents

Software and configuration utilities38

Strona 33

5 TroubleshootingTroubleshooting resourcesRefer hardware and software issues with your Virtualization Services Manager server to HP Services.An additi

Strona 34 - USB support

Management tools ... 30Automatic Serv

Strona 35 - Diagnostic tools

Important safety informationBefore servicing this product, read the Important Safety Information document provided with the server.Symbols on equipme

Strona 36 - Keeping the system current

Warnings and cautionsWARNING!Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshootingand repair procedur

Strona 37 - Care Pack

CAUTION:To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the frontand back of the server.CAUTION:The server

Strona 38

6. Collect all tools and utilities, such as a Torx screwdriver, loopback adapters, ESD wrist strap,and software utilities, necessary to troubleshoot t

Strona 39 - 5 Troubleshooting

Start diagnosis flowchartUse the following flowchart to start the diagnostic process.Refer toItem"Power-on problems flowchart (see 44)"1&quo

Strona 40 - Symbols on equipment

Possible causes:• Improperly seated or faulty power supply• Loose or faulty power cord• Power source problem• Power on circuit problem• Improperly sea

Strona 41 - Warnings and cautions

POST problems flowchartSymptoms:• Server does not complete POSTNOTE:The server has completed POST when the system attempts to access the boot device.•

Strona 42 - Symptom information

Possible problems:• Improperly seated or faulty internal component• Faulty KVM device• Faulty video deviceRefer toItem"POST error messages and be

Strona 43 - Troubleshooting flowcharts

Server fault indications flowchartSymptoms:• Server boots, but a fault event is reported by Insight Management Agents (see page 32)• Server boots, but

Strona 44 - Start diagnosis flowchart

Possible causes:• Improperly seated or faulty internal or external component• Unsupported component installed• Redundancy failure• System overtemperat

Strona 45

A Regulatory compliance notices ... 55Regulatory compliance identification numbers ...

Strona 46 - POST problems flowchart

POST error messages and beep codesFor a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant ServersTro

Strona 47

6 Support and other resourcesHP technical supportFor worldwide technical support information, see the HP support website:http://www.hp.com/supportBefo

Strona 48 - Troubleshooting48

Document conventions and symbolsTable 10 Document conventionsElementConventionCross-reference links and e-mail addressesBlue text: Table 10Website add

Strona 49

Customer self repairThis product has no customer-replaceable components.Subscription serviceHP recommends that you register your product at the Subscr

Strona 50 - WARNING!

Support and other resources54

Strona 51 - 6 Support and other resources

A Regulatory compliance noticesRegulatory compliance identification numbersFor the purpose of regulatory compliance certifications and identification,

Strona 52

interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can

Strona 53 - Product feedback

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matérielbrouilleur du Canada.Class B equipmentThis Class B dig

Strona 54 - Support and other resources54

Japanese noticeBSMI noticeKorean noticeClass A equipmentClass B equipmentRegulatory compliance notices58

Strona 55 - Class B equipment

Chinese noticeLaser complianceThis product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiberoptic transceiver. Ea

Strona 56 - Modifications

TablesFront panel components ... 71Front panel LEDs and butt

Strona 57

For more information about battery replacement or proper disposal, contact an authorized reselleror an authorized service provider.Taiwan battery recy

Strona 58 - Korean notice

B Electrostatic dischargePreventing electrostatic dischargeTo prevent damaging the system, be aware of the precautions you need to follow when setting

Strona 60

C SpecificationsEnvironmental specificationsValueSpecificationTemperature range*10°C to 35°C (50°F to 95°F)Operating-40°C to 70°C (-40°F to 158°F)Ship

Strona 61 - B Electrostatic discharge

ValueSpecificationHP 72GB 15k SAS 2.5 HP DP HDDDisk drives (2)HP FC1242Sr 4Gb PCI-E DCHost bus adapters (2)12.7 mm SATA DVD kitDVDPower supply specifi

Strona 62 - Electrostatic discharge62

• x1 or x4 lane link interface (auto negotiated with system) at 2.5 Gb/s• Support for VC0 (1 Virtual Channel) and TC0 (1 Traffic Class)• Configuration

Strona 64 - Power supply specifications

D Acronyms and abbreviationsabnormal endABENDArray Diagnostics UtilityADUAdvanced Memory ProtectionAMPAutomatic Server RecoveryASRbattery-backed write

Strona 65

ROM-Based Setup UtilityRBSURegistered Dual In-line Memory ModuleRDIMMRapid Deployment PackRDPRemote Insight Lights-Out EditionRILOEserial attached SCS

Strona 66 - Specifications66

IndexAACU (Array Configuration Utility, 29ADU (Array Diagnostics Utility), 35Advanced ECC memory, 28airflow requirements, 21, 22Altiris eXpress Deploy

Strona 67 - D Acronyms and abbreviations

1 Component identificationFront panel componentsTable 1 Front panel componentsDescriptionItemHard drive bay 5 (not used)1Hard drive bay 6 (not used)2D

Strona 68

front panel LEDs, 8Ggrounding methods, 61grounding requirements, 23Hhard drive bays, 7hard drive LEDs, 15hard drives, 7, 14, 15hard drives, determinin

Strona 69

problem diagnosis, 39products, providing feedback, 53ProLiant Support Pack (PSP), 36Rrackinstallation, 24mounting hardware, 24planning resources, 21st

Strona 70

Wwarnings, 24, 41websitesHP, 53HP Subscriber's Choice for Business, 53product manuals, 5172

Strona 71

Front panel LEDs and buttonsTable 2 Front panel LEDs and buttonsStatusDescriptionItemBlue = Identification is activated.Flashing blue = System is bein

Strona 72

Rear panel componentsTable 3 Rear panel componentsDescriptionItemHP FC1242SR 4Gb PCI-e DC HBA 11HP FC1242SR 4Gb PCI-e DC HBA 22Power supply 1 (750 W)3

Komentarze do niniejszej Instrukcji

Brak uwag