HP StorageWorks
1000/1500 Modular Smart Array Command Line
Interface user guide
This guide details the Command Line Interface (CLI), which is used to configure and manage the following products:
— HP StorageWorks 1000 Modular Smart Array (MSA1000)
— HP StorageWorks 1500 Modular Smart Array (MSA1500)
Part number: 347282–004
Fourth edition: June 2007
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - Interface user guide

HP StorageWorks1000/1500 Modular Smart Array Command Line Interface user guideThis guide details the Command Line Interface (CLI), which is used to co

Strona 3 - Contents

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 111 Overview and setupThe Command Line Interface (CLI) is used to conf

Strona 4

12 Overview and setupCLI commands in redundant configurationsWhen an MSA has two controllers, the same firmware image is run on both controllers. The

Strona 5

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 13Overview of CLI storage configuration proceduresWhen using the CLI t

Strona 6

14 Overview and setupAccessing the CLIThe CLI is accessed through a host computer connected to the serial port of an MSA controller. Use the following

Strona 7 - About this guide

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 15The COM Properties dialog box is displayed. d. Enter the following s

Strona 8

16 Overview and setup

Strona 9 - HP technical support

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 172 Using the CLIManaging and configuring the MSA and its storage incl

Strona 10

18 Using the CLIExample help display_all command and response CLI> help display_allDisplaying list of all currently supported CLI commands:? help a

Strona 11 - 1 Overview and setup

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 19Show commandsThe show command is used to view MSA configuration and

Strona 12 - CLI command syntax

Legal and notice information© Copyright 2002-2007 Hewlett-Packard Development Company, L.P.Hewlett-Packard Company makes no warranty of any kind with

Strona 13

20 Using the CLIExample show disks command and response for an MSA1500 Example show unit # command and response CLI> show disksDisk List: (box,bay)

Strona 14 - Accessing the CLI

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 21Example show globals command and response Example show version comma

Strona 15

22 Using the CLIExample show version -all command and response CLI> show version -allMSA 1500 Firmware Revision: 5.10b414 (SGA0434084)MSA 1500 Firm

Strona 16 - 16 Overview and setup

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 23Example show this_controller command and response CLI> show this_

Strona 17 - 2 Using the CLI

24 Using the CLIExample show connections command and response NOTE: Use the show connections command to verify that all connections to the MSA are rec

Strona 18 - command and response

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 25LUN-related commandsThe following commands are used to physically lo

Strona 19 - Show commands

26 Using the CLICreating LUNsA LUN is a logical storage unit comprised of one or more hard drives. When a LUN is initially created, the LUN Unit ID is

Strona 20 - Example show unit #

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 27IMPORTANT: Maintain a record of the units as they are created. These

Strona 21

28 Using the CLIExample command and response to create a LUN with an assigned spareCLI> add unit 4 data=”disk211-disk212” raid_level=1 spare=”disk2

Strona 22 - 22 Using the CLI

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 29Adding a spare to an existing LUNBasic command add spare unit=<#&

Strona 23

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 3About this guide. . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 24 - 24 Using the CLI

30 Using the CLIDeleting sparesBasic command delete spare unit <#> <diskrange>Command options unit #—the unit that will no longer have acc

Strona 25 - LUN-related commands

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 31Extending a LUNCAUTION: In an HP-UX environment, extending a LUN as

Strona 26 - Creating LUNs

32 Using the CLIThe RAID level of Unit 0 will now be 5.Unit 0 is being migrated.Use “show unit 0” to monitor progress.Changing the cache setting for a

Strona 27

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 33Example command and responseCLI> set preferred_path this_controll

Strona 28 - Example command and response

34 Using the CLIEnabling/disabling automatic path switchingNOTE: This command is available only with active/active firmware (v6.x or later).If implici

Strona 29 - Deleting LUNs

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 35Global commandsThe CLI provides the ability to configure the MSA con

Strona 30 - Expanding an array

36 Using the CLIExample command and response Setting the controller IDThis command can be used to assign a unique name to each controller installed in

Strona 31 - Extending a LUN

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 37Changing the CLI promptTo temporarily change the CLI prompt from the

Strona 32

38 Using the CLI• For newly installed MSA, do not perform a firmware update until the controller batteries are fully charged. • For existing MSA, do n

Strona 33

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 39NOTE: In dual-controller configurations, firmware on the two control

Strona 34

4Basic command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Command options .

Strona 35 - Global commands

40 Using the CLIHost connection commandsEach time the MSA is powered on, all active HBA connections to the MSA are automatically detected and identifi

Strona 36 - Setting hard addressing

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 41Changing the profile of a connection To change the operating-system

Strona 37 - Updating MSA firmware

42 Using the CLIDeleting the user-defined name of a connection To remove the user-defined name associated with a connection to a host: Basic command d

Strona 38 - 38 Using the CLI

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 43Changing the profile modeThis command changes a host profile mode ba

Strona 39 - Overriding the ACU lock

44 Using the CLIAdding to the ACLTwo methods of entering LUN assignments are available:• Adding to the ACL using the connection name• Adding to the AC

Strona 40 - Host connection commands

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 45AStorage overviewArrays and logical drivesThe capacity and performan

Strona 41 - [offset=offset_value]

46 Storage overviewFor data in the logical drive to be readable, the data block sequence must be the same in every stripe. This sequencing process is

Strona 42 - Moving to a different profile

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 47RAID 0—No fault toleranceA RAID 0 configuration (Figure 3) provides

Strona 43 - Access Control List commands

48 Storage overviewIn each mirrored pair, the physical drive that is not busy answering other requests answers any read requests that are sent to the

Strona 44 - Adding to the ACL

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 49Figure 8 RAID 6 array, with four physical hard drives (D1, D2, D3, a

Strona 45 - AStorage overview

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 5Adding a connection . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 46 - Fault-tolerance methods

50 Storage overviewComparison of RAID methodsTable 7 summarizes important features of the different RAID levels.Choosing a RAID levelUse Table 8 to he

Strona 47 - RAID 1+0—Drive mirroring

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 51IndexAAccess Control Lists See ACLACLadding to with the CLI 44comman

Strona 48 - RAID 6—Advanced data guarding

52EXTEND UNIT command 31Ffault tolerance methods 46flashing LEDs, with the CLI 25Gglobal controller settings, changing with the CLI 35Hhard addressing

Strona 49

6Figures1 Multiple physical drives (D1, D2, and D3) in a system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452 Multiple p

Strona 50 - Choosing a RAID level

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 7About this guideThis user guide provides information to help you use

Strona 51

8WARNING! Indicates that failure to follow directions could result in bodily harm or death.CAUTION: Indicates that failure to follow directions could

Strona 52

HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 9HP technical supportTelephone numbers for worldwide technical support

Komentarze do niniejszej Instrukcji

Brak uwag