MSA1000 Controller
18 MSA1000 Controller User Guide
Replacing the Controller Cache Battery Pack
WARNING: There is a risk of explosion, fire, or personal injury if the battery
pack is replaced incorrectly or mistreated. To reduce the risk:
Do not attempt to recharge the battery outside of the controller.
Do not expose to water, or to temperatures higher than 60°C.
Do not abuse, disassemble, crush, puncture, short external contacts, or
dispose of in fire or water.
Replace only with the spare designated for this product.
Array Accelerator battery disposal should comply with local regulations.
Alternatively, return them by established parts return methods to
Hewlett- Packard Corporation for disposal.
Caution: It is important to follow these instructions when replacing
components in the MSA1000. If the procedure is done improperly, it is
possible to lose data or damage equipment. Refer to the “Electrostatic
Discharge” appendix for important information on using the proper
procedures.
To remove the old NiMH battery pack:
1. Remove the MSA1000 Controller Cache, as instructed in the previous
section, “Replacing the MSA1000 Controller Cache.”
2. Push down on the bottom clip of the battery pack, attached near the lower
corner of the Array Accelerator.
See Figure 6 for an illustration.