Flex Copy XP user guide 27
Figure 17 shows an example of the configuration used for the procedure.
Figure 17 RAID Manager XP configuration example
The following procedure shows how to edit the configuration definition file. After performing the following
procedure, you can create or delete Flex Copy XP pairs using the paircreate or pairsplit-S
command.
1. Define paths to the internal LU where the external LU is mapped.
The procedure to set paths to the internal LU, where the external LU is mapped, is exactly the same as
the procedure for the actual local array volume. For instructions, see the HP StorageWorks LUN
Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200.
According to Figure 17, LDEV# = 11 is set to CL1-B in this example.
2. Check the connection configuration using the raidscan command.
Make the configuration definition file without HORCM_DEV and HORCM_INST as follows:
horcm0.conf
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
127.0.0.1 52050 1000 3000
HORCM_CMD
#dev_name dev_name dev_name
/dev/rdsk/c1t2d3