Hp VMA-series Memory Arrays Instrukcja Użytkownika Strona 231

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 265
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 230
AM456-9026A HP VMA SAN Gateway Users Guide 231
SNMP Configuration on the HP VMA SAN Gateway
Use the snmp and snmp-server commands to configure SNMP. It defaults to on.
Trap/Notify Event E-mail and Logged Events
This section lists the trap notify settings, along with their respective event e-mail subject lines,
classifications, and logged events.
*ib-srv1 [ib-srv1: master] (config) # show snmp
SNMP enabled: yes
SNMP port: 161
System location:
System contact:
Read-only community: public
Traps enabled: yes
Trap community: public
Interface listen enabled: yes
No Listen Interfaces.
Trap sinks:
10.1.1.1
Enabled: yes
Type: traps version 2c
Community: public (default)
10.1.1.2
Enabled: yes
Type: traps version 2c
Community: public (default)
Trap/Notify Setting Event Email Subject Class. Logged Event
user-login User %s logged in%s Event /mgmtd/session/events/login
user-logout User %s logged out%s Event /mgmtd/session/events/logout
process-exit Process exit: %s Event /pm/events/failure/unexpected_exit
liveness-failure Process hung: %s Event /pm/events/failure/liveness
cpu-util-high CPU utilization too high Event /stats/events/cpu_util_indiv/rising/error
cpu-util-ok CPU utilization alarm
clearing
Event /stats/events/cpu_util_indiv/rising/clear
paging-high Paging activity too high Event /stats/events/paging/rising/error
paging-ok Paging activity alarm
clearing
Event /stats/events/paging/rising/clear
disk-space-low Disk space low Event /stats/events/fs_mnt_bytes/falling/error
disk-space-ok Disk space OK Event /stats/events/fs_mnt_bytes/falling/clear
Przeglądanie stron 230
1 2 ... 226 227 228 229 230 231 232 233 234 235 236 ... 264 265

Komentarze do niniejszej Instrukcji