Hp XP Command View Advanced Edition Software Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Przechowywanie Hp XP Command View Advanced Edition Software. HP XP Command View Advanced Edition Software User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Web Client User Guide

HP StorageWorks Command View XP Advanced Edition Device Manager Web Client User Guide Part number: T1780-96012 Second edition: October, 2005

Strona 2

About this guide 10 HP technical support Telephone numbers for worldwide technical support are listed on the HP web site: http://www.hp.com/suppo

Strona 3 - Contents

All Storage/My Storage Operations 100 Figure 8-2 Viewing a Storage Subsystem Group in All Storage/My Storage When you select and expand a stora

Strona 4 - Contents 4

All Storage/My Storage Operations 101 Figure 8-3 Viewing the Allocated Group for a Storage Subsystem Select Allocate Storage to add paths to the

Strona 5 - 12 Troubleshooting

All Storage/My Storage Operations 102 Table 8-1 Open-Allocated Group Information under All Storage/My Storage Column Description SLPR Display

Strona 6 - Figures

All Storage/My Storage Operations 103 Table 8-1 Open-Allocated Group Information under All Storage/My Storage Column Description % Used Displays

Strona 7 - Figures 7

All Storage/My Storage Operations 104 Table 8-1 Open-Allocated Group Information under All Storage/My Storage Column Description Copy Type Di

Strona 8 - Tables 8

All Storage/My Storage Operations 105 • Name. Name of the storage subsystem. • Number of LDEVs. Number of LDEVs/LUs for which paths are not alloc

Strona 9 - Prerequisites

All Storage/My Storage Operations 106 Table 8-2 Unallocated Group Information under All Storage/My Storage Column Description LDEV LDEV numb

Strona 10 - Helpful web sites

All Storage/My Storage Operations 107 Table 8-2 Unallocated Group Information under All Storage/My Storage Column Description Copy Status Copy s

Strona 11 - Revision history

All Storage/My Storage Operations 108 Figure 8-5 Viewing the Mainframe-Unspecified Group for a Storage Subsystem Table 8-3 Information for th

Strona 12 - Device Manager

All Storage/My Storage Operations 109 Table 8-3 Information for the Mainframe-Unspecified Group under All Storage/My Storage Item Description Vol

Strona 13 - Software Components

Revision history 11 Revision history Revision tables Table 2 Revisions Date Edition Revision July, 2005 First Initial Release October, 2005 Se

Strona 14

All Storage/My Storage Operations 110 NOTE: If you display the contents of the LUN SCAN group while LUN Scan is being executed and before the

Strona 15

All Storage/My Storage Operations 111 group using the information that was detected by the LUN Scan. For LUN information displayed in the Open-Allo

Strona 16 - 1-5 Syntax Conventions

All Storage/My Storage Operations 112 Figure 8-7 Unallocating Storage – Confirmation 4. Review the warning message. 5. Select OK to delete th

Strona 17

All Storage/My Storage Operations 113 Figure 8-9 Unallocating Storage LUSE – Confirmation 7. Review the warning message and do one of the followi

Strona 18 - 2 Device Manager Operations

All Storage/My Storage Operations 114 • An LDEV set as a command device cannot be used. • An LDEV registered as an external volume cannot be u

Strona 19 - 2-3 Configuration Operations

All Storage/My Storage Operations 115 Figure 8-10 Creating LUSE – Selecting LDEVs For StorageWorks XP12000/XP10000 and XP1024/XP128, the smallest

Strona 20

All Storage/My Storage Operations 116 Figure 8-11 Create LUSE Confirmation and Warning 6. Review the warning information and select the Yes, I

Strona 21

All Storage/My Storage Operations 117 Figure 8-12 Delete LUSE Confirmation and Warning 4. Review the warning information and select the Yes, I ha

Strona 22

Performing Host Operations 118 9 Performing Host Operations This chapter describes Device Manager host operations: • Overview of Device Manager

Strona 23

Performing Host Operations 119 9-2 Viewing the List of Hosts All Device Manager users can view the list of hosts for which they have access permis

Strona 24 - 2-6 Report Operations

Overview of Command View XP Advanced Edition Device Manager 12 1 Overview of Command View XP Advanced Edition Device Manager This chapter provid

Strona 25

Performing Host Operations 120 9-3-1 Adding Hosts by Executing a LUN Scan When you execute a LUN scan operation on a storage subsystem, Device

Strona 26

Performing Host Operations 121 Figure 9-2 Adding a Host – Entering the Name 3. Enter the name for the new host using a maximum of 50 bytes. You

Strona 27 - 3-4-1 Setting Up the Proxy

Performing Host Operations 122 2. Select the desired host in the navigation frame (in this example, aibetsu). The Show Properties subwindow for

Strona 28

Performing Host Operations 123 NOTE: The Create Pair, Modify Pair, and Delete Pair buttons do not appear when you have logged on as a guest or l

Strona 29 - 3-5 Upgrading Device Manager

Performing Host Operations 124 Figure 9-6 Modifying Host Properties 4. Modify the host properties as needed on the Modify Properties panel. Yo

Strona 30

Performing Host Operations 125 Figure 9-8 Modifying Host Properties – Selecting LUN Security Changes Select at least one checkbox for the storage

Strona 31

Performing Host Operations 126 Figure 9-9 Modifying Host Properties – Confirming LUN Security Changes 9-6 Updating (Refreshing) Host Informatio

Strona 32

Performing Host Operations 127 CAUTION: When you update the host information, the status of the copy pairs managed by the host is updated, but t

Strona 33

Performing Host Operations 128 Figure 9-11 Refreshing Host Information – Confirmation 9-7 Managing Copy Pairs The system administrator, local s

Strona 34 - 4-3 Copy Pair Requirements

Performing Host Operations 129 2. Select and expand the Hosts object in the navigation frame (refer to Figure 9-1). 3. In the navigation frame s

Strona 35 - 4-3-2 S-VOL Requirements

Overview of Command View XP Advanced Edition Device Manager 13 1-2 Related Software Products The following software products are related to Device

Strona 36

Performing Host Operations 130 Group. Select the desired copy group for all copy pairs being created, or create a new group if desired. For deta

Strona 37 - Manager main window

Performing Host Operations 131 Figure 9-12 Creating a Pair – Selecting P-VOLs Figure 9-13 Creating a Pair – Choosing Pair(s) Step

Strona 38

Performing Host Operations 132 Figure 9-14 Creating a Pair – Selecting S-VOL(s) Figure 9-15 Creating a Pair – Defining Pair(s) Step

Strona 39

Performing Host Operations 133 Figure 9-16 Creating a Pair – Viewing Pair Information NOTE: The displayed host is the host that manages copy pa

Strona 40

Performing Host Operations 134 Figure 9-18 Creating a Pair – Confirmation Step Figure 9-19 Creating a Pair – Warning of Data Loss 9-7-2 Modif

Strona 41

Performing Host Operations 135 Table 9-1 Modify Pair Operations Target of Operation Operations that can be performed Copy group If one or more

Strona 42

Performing Host Operations 136 5. Select Modify Pair(s) Step. The Select Modify Pair(s) panel (see Figure 9-21) allows you to select the copy g

Strona 43 - Device Manager main window

Performing Host Operations 137 Figure 9-20 Modifying a Pair – Selecting the Host Figure 9-21 Modifying a Pair – Select Modify Pair(s) Step NOT

Strona 44

Performing Host Operations 138 Figure 9-22 Modifying Pair(s) Step Figure 9-23 Modifying a Pair – Summary of Changes Step

Strona 45

Performing Host Operations 139 Figure 9-24 Modifying a Pair – Warning of I/O Activity on P-VOL 9-7-3 Notes on Copy Pair Operations This subsectio

Strona 46 - 5-2-1 Menu Bar

Overview of Command View XP Advanced Edition Device Manager 14 • Web Client. Device Manager Web Client provides two types of user interfaces, a

Strona 47 - 5-2-3 Pop-up Windows

Performing Host Operations 140 Table 9-3 Items to Consider Before Creating Copy Pairs Item Description Central management method When a single

Strona 48

Performing Host Operations 141 Table 9-4 Notes on Copy Pair Operations Item Description Error code 7774 Error code 7774 occurs when the Device

Strona 49

Performing Host Operations 142 Table 9-4 Notes on Copy Pair Operations Item Description *1An error might occur when attempting to create a cop

Strona 50

Performing Host Operations 143 Table 9-5 Notes on Managing the Host Item Description When buttons for copy pair functionality are not displayed I

Strona 51 - 5-5-1 Viewing Alerts

Performing Host Operations 144 Figure 9-25 Deleting a Pair – Select Delete Pair(s) Step NOTE: The displayed host is the host that manages cop

Strona 52 - 5-5-2 Monitoring Alerts

Performing Host Operations 145 1. Log in to Device Manager as a system administrator, storage administrator, local system administrator, or local

Strona 53 - 5-5-3 Deleting Alerts

Performing Storage Subsystem Operations 146 10 Performing Storage Subsystem Operations This chapter describes Device Manager storage subsystem o

Strona 54 - 5-6 Viewing the Task List

Performing Storage Subsystem Operations 147 When the Subsystems object is selected in the navigation frame, the method frame displays the Add Subs

Strona 55 - 5-7-1 Launching HDLM

Performing Storage Subsystem Operations 148 NOTE: If you are using StorageWorks XP12000/XP10000 External Storage XP, note the following points

Strona 56

Performing Storage Subsystem Operations 149 Figure 10-2 Adding a Subsystem 10-1-3 Viewing and Editing Storage Subsystem Properties The system ad

Strona 57

Overview of Command View XP Advanced Edition Device Manager 15 • Continuous Access XP: The Continuous Access XP feature enables the user to make

Strona 58

Performing Storage Subsystem Operations 150 3. To modify the storage subsystem properties, select the Modify Properties method in the method fr

Strona 59

Performing Storage Subsystem Operations 151 Figure 10-4 Modifying Properties (StorageWorks XP1024/XP128) 10-1-4 Performing a Refresh Operation Th

Strona 60 - 6-2 User Account Operations

Performing Storage Subsystem Operations 152 2. Select and expand the Subsystems object in the navigation frame, and then select the desired sto

Strona 61

Performing Storage Subsystem Operations 153 NOTE: If you remove a storage subsystem that has alert information, and then attempt to display the

Strona 62 - 6-2-3 Changing Your Password

Performing Storage Subsystem Operations 154 • Viewing detailed information for StorageWorks XP1024/XP128 (see section 10-2-2) • Viewing detail

Strona 63 - 6-2-4 Deleting a User

Performing Storage Subsystem Operations 155 belonging to the representative VDEV. No information displays for array groups that do not belong to t

Strona 64 - 6-3 User Group Operations

Performing Storage Subsystem Operations 156 Figure 10-8 Physical View for StorageWorks XP1024/XP128 (Array Groups) The StorageWorks XP1024/XP12

Strona 65

Performing Storage Subsystem Operations 157 Figure 10-9 Frame Information Panel for StorageWorks XP1024/XP128 (Level 1) The StorageWorks XP1024/X

Strona 66

Performing Storage Subsystem Operations 158 Figure 10-10 Discrete VDEV Configuration for StorageWorks XP1024/XP128

Strona 67 - 6-3-3 Deleting a User Group

Performing Storage Subsystem Operations 159 Figure 10-11 Frame Information Panel for Discrete VDEV Configuration

Strona 68

Overview of Command View XP Advanced Edition Device Manager 16 • Snapshot XP: The Snapshot XP feature (for StorageWorks XP12000/XP10000 only) a

Strona 69

Performing Storage Subsystem Operations 160 Figure 10-12 Frame Information Panel for StorageWorks XP1024/XP128 (Level 2) The Frame Information

Strona 70 - 7-3 Creating a Logical Group

Performing Storage Subsystem Operations 161 Figure 10-13 Physical View for StorageWorks XP1024/XP128 (Disks) The disks view of the StorageWorks

Strona 71

Performing Storage Subsystem Operations 162 8. In the Frame Information panel, you can select the desired array group to open the LDEV Informat

Strona 72 - 7-5 Deleting a Logical Group

Performing Storage Subsystem Operations 163 Figure 10-15 Physical View for StorageWorks XP512/XP48 (Array Groups) The StorageWorks XP512/XP48 phy

Strona 73

Performing Storage Subsystem Operations 164 Figure 10-16 Frame Information Panel for StorageWorks XP512/XP48 The Frame Information panel displ

Strona 74 - 7-6 Storage Group Operations

Performing Storage Subsystem Operations 165 10-2-4 Viewing LDEV Information The system administrator, storage administrator, and guest users can v

Strona 75

Performing Storage Subsystem Operations 166 Figure 10-18 LDEV Information Panel – Detail Tab The Detail tab of the LDEV Information panel displ

Strona 76

Performing Storage Subsystem Operations 167 Figure 10-19 LDEV Information Panel – Path Info Tab The Path Info tab of the LDEV Information panel d

Strona 77

Performing Storage Subsystem Operations 168 Figure 10-20 LDEV Information Panel – Pair Info Tab The Pair Info tab of the LDEV Information panel

Strona 78

Performing Storage Subsystem Operations 169 10-3 Port Operations Device Manager port operations include: • Configuring the ports (StorageWorks XP

Strona 79 - Figure 7-20)

Overview of Command View XP Advanced Edition Device Manager 17 Table 1-2 Syntax Conventions Font or Symbol How Used [ ] An item or items encl

Strona 80

Performing Storage Subsystem Operations 170 NOTE: If you change the Topology (Connection) settings, the attributes displayed by Web Client may

Strona 81

Performing Storage Subsystem Operations 171 • Fibre Addr: In fabric environments, the port address is assigned automatically by fabric switch po

Strona 82

Performing Storage Subsystem Operations 172 • Modify WWN Group: Opens the Modify WWN Group panel (see section 10-3-3) • WWN Info button: Dis

Strona 83

Performing Storage Subsystem Operations 173 4. Select MODIFY LUN GROUP to open the Modify LUN Group panel (refer to Figure 10-23). 5. Select CRE

Strona 84

Performing Storage Subsystem Operations 174 Figure 10-25 Creating a New LUN Group – Selecting the WWN(s) Figure 10-26 Creating a New LUN Grou

Strona 85

Performing Storage Subsystem Operations 175 5. Select the desired LUN group, and make the desired changes to the LUN group. Select the LUN tab to

Strona 86

Performing Storage Subsystem Operations 176 Figure 10-27 Modify WWN Group Panel The Select WWN Group drop-down list box allows you to select th

Strona 87

Performing Storage Subsystem Operations 177 2. Select the Subsystems object in the navigation frame, select the desired storage subsystem, and th

Strona 88

Performing Storage Subsystem Operations 178 4. Make the desired channel adapter mode changes, and select OK. 5. Before changing the fibre PCB

Strona 89

Performing Storage Subsystem Operations 179 Figure 10-29 Changing the Channel Adapter Mode Confirmation 10-4 LDEV Operations Device Manager LDEV

Strona 90

Device Manager Operations 18 2 Device Manager Operations This chapter describes Device Manager operations: • User groups and user access levels

Strona 91

Performing Storage Subsystem Operations 180 4. Define Host/Port Connections Step. The Define Host/Port Connections panel (see Figure 10-30) all

Strona 92

Performing Storage Subsystem Operations 181 Figure 10-31 Allocating Storage – Assigning Host/Port Connections Figure 10-32 Allocating Storage

Strona 93

Performing Storage Subsystem Operations 182 Figure 10-33 Allocating Storage – Confirmation 10-4-2 Unallocating Storage (Removing Volume Paths)

Strona 94

Performing Storage Subsystem Operations 183 Figure 10-34 Unallocating Storage – Confirmation Figure 10-35 Unallocating Storage – Delete LUSE or

Strona 95

Performing Storage Subsystem Operations 184 CAUTION: For the StorageWorks XP1024/XP128 and StorageWorks XP512/XP48 storage subsystems, you can

Strona 96

Performing Storage Subsystem Operations 185 Figure 10-36 Creating an LDEV – Specifying LDEV Parameters (XP512/XP48) Figure 10-37 Creating an LD

Strona 97

Performing Storage Subsystem Operations 186 • An LDEV used as a command device • An LDEV specified as a copy volume (P-VOL, S-VOL, or SP-VOL)

Strona 98

Performing Storage Subsystem Operations 187 • Command device security can be set. For XP512/XP48, when you delete a command device, its security

Strona 99

Performing Report Operations 188 11 Performing Report Operations This chapter describes the different types of Device Manager reports that you c

Strona 100

Performing Report Operations 189 Figure 11-2 Physical Configuration of Storage Subsystem Report – HTML Figure 11-3 Physical Configuration of S

Strona 101

Device Manager Operations 19 Table 2-1 Device Manager User Roles User Role Description Storage Administrator Configures and manages storage sub

Strona 102

Performing Report Operations 190 Figure 11-4 Storage Utilization by Host Report (HTML) 11-4 Storage Utilization by Logical Group Report The St

Strona 103

Performing Report Operations 191 Figure 11-5 Storage Utilization by Logical Group Report (HTML) 11-5 Users and Permissions Report The Users and P

Strona 104

Troubleshooting 192 12 Troubleshooting This chapter describes Device Manager Web Client troubleshooting. • For general information on troublesh

Strona 105

Troubleshooting 193 Table 12-1 General Troubleshooting Information Problem Description The File Download panel displays when you invoke the Java™

Strona 106

Troubleshooting 194 Table 12-1 General Troubleshooting Information Problem Description The Dynamic Link Manager button is not displayed in the

Strona 107

Troubleshooting 195 Table 12-1 General Troubleshooting Information Problem Description When Device Manager has not created a copy pair for an LDE

Strona 108

Troubleshooting 196 For example, depending on hardware, the servers and HBAs may not recognize the LUNs using the subject port unless a specific

Strona 109

Troubleshooting 197 12-3-8 An Internal Volume Mapped to an External Volume Is Invalid An internal volume mapped with an external volume may become

Strona 110

Troubleshooting 198 Confirm that all hosts have been added into the host view before running a LUN Scan. After LUN Scan, Device Manager creates

Strona 111 - 8-5 Unallocating Storage

Acronyms and Abbreviations 199 Acronyms and Abbreviations ACP array control processor (back-end array processor on the XP1024/XP128 and XP512/XP4

Strona 112

2 Legal notices © Copyright 2005 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company makes no warranty of any kind with regard to this

Strona 113 - 8-6 Creating LUSE Devices

Device Manager Operations 20 for each storage subsystem on which the LUN Scan is performed. This logical group is created in the LUN SCAN group

Strona 114

Acronyms and Abbreviations 200 JRE Java™ Runtime Environment JWS Java™ Web Start software KB kilobyte (1024 bytes) LAN local area network

Strona 115

Acronyms and Abbreviations 201 URL uniform resource locator VDEV virtual device VM Volume Manager VPN virtual private network VxVM VERITAS™

Strona 116 - 8-7 Deleting LUSE Devices

Device Manager Operations 21 The cache logical partition function allows you to establish an environment in which I/O operations on a specific vol

Strona 117

Device Manager Operations 22 is the default mode. High-speed mode provides faster access speed by using more processors to handle data access. H

Strona 118 - 9 Performing Host Operations

Device Manager Operations 23 NOTE: The data management function must be installed and available on the storage subsystem. 2-4-1 Managing Data o

Strona 119 - 9-3 Adding a Host

Device Manager Operations 24 • Continuous Access XP. Continuous Access XP allows you to perform synchronous and asynchronous remote copy operat

Strona 120 - 9-3-2 Adding Hosts Manually

Installing Device Manager Web Client 25 3 Installing Device Manager Web Client This chapter describes the requirements for Web Client operations,

Strona 121

Installing Device Manager Web Client 26 • Storage subsystems. Before adding a storage subsystem to Device Manager using Web Client (or another

Strona 122

Installing Device Manager Web Client 27 To install JRE and JWS: 1. Download the platform-specific installer for JRE version 1.4.2_xx (xx: 06 or

Strona 123

Installing Device Manager Web Client 28 browser proxy configuration (such as automatic configuration in Internet Explorer), Java™ Web Start does

Strona 124

Installing Device Manager Web Client 29 To clear the cache in Java™ Web Start: 1. Start the Java™ Web Start application manager. 2. Select the

Strona 125

Contents 3 Contents Revision history Revision tables ...

Strona 126

Installing Device Manager Web Client 30 3-6 Setting Up Secure Communication with Device Manager When setting up a Device Manager system, you nee

Strona 127

Preparing for and Starting Operations 31 4 Preparing for and Starting Operations This chapter describes the preparation required before using Devi

Strona 128 - 9-7 Managing Copy Pairs

Preparing for and Starting Operations 32 If Device Manager and another management tool (such as XP12000/XP10000, XP1024/XP128 Remote Web Console

Strona 129

Preparing for and Starting Operations 33 CAUTION: When using Netscape® or Mozilla™ in a Solaris™ or HP-UX environment, you must specify the foll

Strona 130

Preparing for and Starting Operations 34 Third-Party Software Application Requirements If the third-party software applies to a specific array,

Strona 131

Preparing for and Starting Operations 35 Table 4-1 Requirements for a logical device to be selectable as a primary volume (SP-volume) Storage sub

Strona 132

Preparing for and Starting Operations 36 Table 4-2 Requirements for a logical device to be selectable as a secondary volume Storage subsystem

Strona 133

Preparing for and Starting Operations 37 To log in to Device Manager: 1. Launch the web browser, and enter the URL for the Device Manager server:

Strona 134 - 9-7-2 Modifying Copy Pairs

Preparing for and Starting Operations 38 Figure 4-1 Command View XP AE Device Manager Login Panel with License Warning Figure 4-2 Version Inf

Strona 135

Preparing for and Starting Operations 39 Figure 4-3 Command View XP AE Device Manager Main Window – Initial Start-Up 4-5 Starting Device Manager

Strona 136

Contents 4 5-5-1 Viewing Alerts...

Strona 137

Preparing for and Starting Operations 40 4. Add the connected storage subsystems to the Device Manager server (see section 10-1-2). Volumes tha

Strona 138

Preparing for and Starting Operations 41 Figure 4-4 System Configuration Using External Storage XP When using External Storage XP, you can manage

Strona 139

Preparing for and Starting Operations 42 3. Specify an external subsystem port to be connected to the external port. For details on the setting

Strona 140

Performing Device Manager System Operations 43 5 Performing Device Manager System Operations This chapter describes Device Manager system operatio

Strona 141

Performing Device Manager System Operations 44 Figure 5-1 Command View XP AE Device Manager Login Panel 5-1-2 Logging Out of Device Manager Eac

Strona 142

Performing Device Manager System Operations 45 CAUTION: If you are using Netscape® as your Web browser, multiple unnecessary windows will be dis

Strona 143 - 9-7-4 Deleting Copy Pairs

Performing Device Manager System Operations 46 • Method frame. Displays the available operations for the object selected in the navigation fram

Strona 144 - 9-8 Removing a Host

Performing Device Manager System Operations 47 A link to Product Documentation Home Page appears in Other Application. Clicking this link displays

Strona 145

Performing Device Manager System Operations 48 Figure 5-4 Pop-up Window The common items displayed on all pop-up windows are described below: •

Strona 146

Performing Device Manager System Operations 49 5-3 Viewing Version and License Type Information The Version Information of Device Manager panel, s

Strona 147

Contents 5 10 Performing Storage Subsystem Operations 10-1 Overview of Storage Subsystem Operations...

Strona 148

Performing Device Manager System Operations 50 Figure 5-6 Show User Profile Panel 5-5 Performing Alert Operations The Device Manager alert oper

Strona 149

Performing Device Manager System Operations 51 Figure 5-7 Alerts 5-5-1 Viewing Alerts Device Manager allows you to view a list of all alerts for

Strona 150

Performing Device Manager System Operations 52 CAUTION: If you remove a storage subsystem that has alert information, and then attempt to disp

Strona 151

Performing Device Manager System Operations 53 Figure 5-9 Monitor – Alerts Panel Showing Monitoring Figure 5-10 Monitor – Alerts Panel Showing

Strona 152

Performing Device Manager System Operations 54 2. Select the checkbox for each alert that you want to delete. To select all checkboxes, click t

Strona 153

Performing Device Manager System Operations 55 NOTE: If you log out of Command View XP AE Suite software that you launched using the link-and-la

Strona 154

Performing Device Manager System Operations 56 • Physical view dialog box. For StorageWorks XP1024/XP128, the Remote Web Console drop-down list

Strona 155

Performing Device Manager System Operations 57 Figure 5-13 Starting Remote Web Console for StorageWorks XP1024/XP128 (Show Properties - subsystem

Strona 156

Performing Device Manager System Operations 58 4. Check the message in the download dialog box and choose the Save button. The Save As dialog b

Strona 157

Performing User Management Operations 59 6 Performing User Management Operations This chapter describes Device Manager user management operations.

Strona 158

Figures 6 Figures Figure 1-1 Command View XP Advanced Edition Device Manager System and Software Components... 14 Figure 2-1 Using

Strona 159

Performing User Management Operations 60 6-2 User Account Operations System administrators can manage all user accounts The local system adminis

Strona 160

Performing User Management Operations 61 To create a new Device Manager user: 1. Log in to Device Manager as a system administrator or local admi

Strona 161

Performing User Management Operations 62 6-2-2 Viewing and Editing User Properties All Device Manager users except for guests and local guests c

Strona 162

Performing User Management Operations 63 NOTE: The password is case-sensitive and must be 4 to 25 bytes long. You can use the following characte

Strona 163

Performing User Management Operations 64 Figure 6-6 Deleting a User –Confirmation 5. Select YES to delete the user, or select NO to cancel you

Strona 164

Performing User Management Operations 65 When a user group is created, the name of the user group is entered and the resources (logical groups, ho

Strona 165

Performing User Management Operations 66 Figure 6-8 Creating a New User Group 6-3-2 Viewing and Editing User Group Properties The system admini

Strona 166

Performing User Management Operations 67 To view and edit the user group properties: 1. Log in to Device Manager as system administrator or local

Strona 167

Performing User Management Operations 68 NOTE: Users in the selected user group and its descendant groups (if any) will be deleted. 5. When

Strona 168

Performing Logical Group Operations 69 7 Performing Logical Group Operations This chapter describes logical group operations: • Overview of Logic

Strona 169 - 10-3 Port Operations

Figures 7 Figure 8-1 All Storage or My Storage ...

Strona 170

Performing Logical Group Operations 70 group contains an Open-Allocated group and an Open-Unallocated group. For the StorageWorks XP Disk Array,

Strona 171

Performing Logical Group Operations 71 NOTE: In Web Client, increasing the amount of data that is displayed in the window increases the amount o

Strona 172 - 10-3-2 Managing LUN Groups

Performing Logical Group Operations 72 1. Select the Logical Groups object in the navigation frame, expand the tree as needed (click on +), and

Strona 173

Performing Logical Group Operations 73 NOTE: For instructions on deleting a storage group (contains LUNs) or a parent group which contains one o

Strona 174

Performing Logical Group Operations 74 Figure 7-5 Deleting a Logical Group with Subgroups – Confirmation 3. Select OK to delete the logical gr

Strona 175 - 10-3-3 Managing WWN Groups

Performing Logical Group Operations 75 7-6-1 Viewing the Contents of a Storage Group When you view the contents of a storage group, you can view p

Strona 176

Performing Logical Group Operations 76 Figure 7-7 Detailed Information – LDEV-Number Panel Table 7-1 describes the information displayed on the

Strona 177

Performing Logical Group Operations 77 Table 7-1 LDEV-Number Panel Detailed Information Item Description File System Displays the mount point

Strona 178

Performing Logical Group Operations 78 Table 7-1 LDEV-Number Panel Detailed Information Item Description Disk/Cache Partition Information Displ

Strona 179 - 10-4 LDEV Operations

Performing Logical Group Operations 79 If the selected storage group is empty or different security settings are specified for the paths in the se

Strona 180

Tables 8 Figure 10-27 Modify WWN Group Panel ...

Strona 181

Performing Logical Group Operations 80 NOTE: Each StorageWorks XP12000/XP10000 and XP1024/XP128 port has its own host storage domains with LUN

Strona 182

Performing Logical Group Operations 81 8. Define LUs step (optional). The Define LUs panel (Figure 7-18) allows you to create LUSE devices. If yo

Strona 183 - 10-4-3 Creating an LDEV

Performing Logical Group Operations 82 Figure 7-8 Adding Storage – Selecting the Group Figure 7-9 Adding Storage – Selecting the Storage Addi

Strona 184

Performing Logical Group Operations 83 Figure 7-10 Selecting the Logical Group Figure 7-11 Adding Storage – Selecting Ports

Strona 185 - 10-4-4 Deleting an LDEV

Performing Logical Group Operations 84 Figure 7-12 Adding Storage – Defining Host/Port Connections NOTE: You can only select a storage subsys

Strona 186

Performing Logical Group Operations 85 Figure 7-14 Host Storage Domain Info Figure 7-15 Adding Storage – Allocating Storage

Strona 187

Performing Logical Group Operations 86 Figure 7-16 Adding Storage – Browsing for LDEVs Figure 7-17 Adding Storage – Storage Found

Strona 188

Performing Logical Group Operations 87 Figure 7-18 Adding Storage – Defining LUs Figure 7-19 Adding Storage – Assigning Host/Port Connection

Strona 189

Performing Logical Group Operations 88 Figure 7-20 Adding Storage – Assigning LUNs Figure 7-21 Adding Storage – Confirmation 7-6-3 Moving Sto

Strona 190

Performing Logical Group Operations 89 1. Log in to Device Manager as a system administrator, storage administrator, local system administrator,

Strona 191

About this guide 9 About this guide This document describes and provides instructions for using the HP StorageWorks XP Advanced Edition Device Man

Strona 192 - 12 Troubleshooting

Performing Logical Group Operations 90 Figure 7-22 Moving Storage – Selecting the Path(s) Figure 7-23 Moving Storage – Selecting the Targe

Strona 193 - Troubleshooting 193

Performing Logical Group Operations 91 Figure 7-24 Moving Storage – Confirmation 7-6-4 Modifying LUN Security for a Group The system administrato

Strona 194 - Troubleshooting 194

Performing Logical Group Operations 92 • Not assigned (Current Status) • Assign this security to all selected paths b. If the selected WWNs a

Strona 195 - 12-3 Warning Messages

Performing Logical Group Operations 93 Figure 7-26 Modifying Security – Step 2: Select WWNs Figure 7-27 Modifying Security – Warning

Strona 196 - Troubleshooting 196

Performing Logical Group Operations 94 Figure 7-28 Modifying Security – Step 3: Summary of Changes and Confirmation 7-6-5 Removing Storage fro

Strona 197 - Troubleshooting 197

Performing Logical Group Operations 95 The Remove Storage – Confirmation panel displays, with a list of LUNs you are deleting, as shown in Figure

Strona 198 - 12-4 Error Messages

Performing Logical Group Operations 96 CAUTION: Data may be lost if LUNs are released. Before deleting a storage group, you should back up the

Strona 199 - Acronyms and Abbreviations

Performing Logical Group Operations 97 CAUTION: Before deleting a path, make sure that the path is no longer in use. NOTE: For LUSE: If all pa

Strona 200

All Storage/My Storage Operations 98 8 All Storage/My Storage Operations This chapter describes All Storage/My Storage logical group operations:

Strona 201

All Storage/My Storage Operations 99 Figure 8-1 All Storage or My Storage • Number of LDEVs = total number of LDEVs in the All Storage or My Sto

Komentarze do niniejszej Instrukcji

Brak uwag