Use the HP sp400 Series Configuration Software
Imager tab
The Imager tab allows you to configure factors that affect the operation of the All-in-One imager module.
The All-in-One uses the Hand Held Products 5X80 imager module.
For additional information about configuring the imager, see the HandHeld Products 5X80 User’s Guide
available for download at
www.handheld.com.
Initialization String: A string of commands that are sent to the imager when the All-in-One is
turned on.
Termination String: A string of characters that are added to the end of the scanned string. To
enter non-ASCII characters, use a forward slash followed by two hex digits. A single forward slash
may be entered as //.
Imager Pre-Trigger: Selecting the Pre-Trigger check box causes the imager to enter the triggered
state immediately after a scan is complete.
Barcode Read Pre-presentation Timeout (ms): The number of milliseconds the imager waits to
scan a bar code before it exits the triggered state.
NOTE: The Barcode Read Pre-presentation Timeout (ms) box is only activated when the Pre-
Trigger check box is selected.