Hp Integrity rx4610 Server Instrukcja Użytkownika Strona 175

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 174
Chapter 11 Troubleshooting
167
3. Replace the DC-DC Converters.
If the HP Server’s SCSI Drives Are Not Recognized
Check the following if the SCSI drives are not recognized during POST:
1. Check the seating of the Internal SCSI Cable between the I/O Board and
the Power Distribution Board (T-Docking).
2. Check that the SCSI drives are enabled in the BIOS Setup.
If the HP Server’s IDE Drives Are Not Recognized
Check the following if the IDE drives are not recognized during POST:
1. Check the seating of the IDE cables and power cables.
2. Check that the IDE drives are enabled in the BIOS Setup.
HP Server rx4610 SEL Data Tables
The tables in this appendix provide information on the SEL viewer data on the HP
Server rx4610 server platform.
HP Server rx4610 Generator ID Codes
Generator ID Description
20 00 BMC
28 00 CBC
C0 00 HSC
Przeglądanie stron 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 248 249

Komentarze do niniejszej Instrukcji

Brak uwag