Strona 2

About This Guide Related Documents For additional information on the topics covered in this guide, refer to the following documentation: • HP ProLian

Strona 3 - Contents

Server Blade Troubleshooting Accessing the Redundant ROM If the system ROM is corrupted, you can set the system to use the backup version or redundant

Strona 4

Server Blade Troubleshooting A-16 HP ProLiant BL20p Generation 3 Server Blade User Guide If both the current and backup versions of the R

Strona 5

B Battery Replacement System Board Battery Replacement When the server blade no longer automatically displays the correct date and time, you may need

Strona 6

Battery Replacement B-2 HP ProLiant BL20p Generation 3 Server Blade User Guide 2. Locate the battery holder on the system board. 3. Pus

Strona 7 - About This Guide

HP ProLiant BL20p Generation 3 Server Blade User Guide C-1 the user's authority to operate the equipment. C Regulatory Compliance No

Strona 8

Regulatory Compliance Notices Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to ma

Strona 9 - Symbols in Text

Regulatory Compliance Notices Korean Notice BSMI Notice Battery Replacement Notice Your computer is provided with an internal lithium battery or ba

Strona 10 - Getting Help

Regulatory Compliance Notices C-4 HP ProLiant BL20p Generation 3 Server Blade User Guide WARNING: Your computer contains an internal

Strona 11 - Reader’s Comments

D Electrostatic Discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts.

Strona 12 - Server Blade Front Panel

Electrostatic Discharge D-2 HP ProLiant BL20p Generation 3 Server Blade User Guide Grounding Methods Several methods for grounding are av

Strona 13

About This Guide Be sure to have the following information available before you call HP: • Technical support registration number (if applicable) •

Strona 14 - Hot-Plug SCSI Hard Drive

HP ProLiant BL20p Generation 3 Server Blade User Guide Index-1 creating 5-32 using 5-33 Index A access panel, removing 3-2 accessi

Strona 15

Index D deployment CD-ROM image 5-30 diskette image 5-32 HP ProLiant Essentials Rapid Deployment Pack 5-28 iLO 5-31, 5-33 infrastructure 5-2

Strona 16

Index I identifying system board components 1-9 system board connectors 1-9 installing DIMMs 4-9 hard drive blanks 4-6 hot-plug SCSI hard driv

Strona 17 - Power Button

Index O operating systems 5-33 Option ROM Configuration for Arrays utility (ORCA) 5-12 override, power-up 2-1 P part number, battery B-1 POST

Strona 18 - System Switches

Index S safety product C-2 SAN 5-34 SCSI backplane A-6 SCSI hard drives, LEDs 1-3 SCSI IDs 4-6 server blade blanks airflow 3-4 removing

Strona 19 - System Settings Switch

Index U unit identification (UID), LEDs 1-2 upgrading, BIOS 5-7 USB CD-ROM, deployment 5-31 utilities ASR-2 5-16 Diagnostics 5-16 HP ProLian

Strona 20

1 Server Blade Component Identification LEDs The system contains several sets of LEDs that indicate the status and settings of hardware components. Us

Strona 21

Server Blade Component Identification Figure 1-1: ProLiant BL20p G3 server blade front panel LEDs Table 1-1: ProLiant BL20p G3 Server Blade Front

Strona 22

Server Blade Component Identification Table 1-1: ProLiant BL20p G3 Server Blade Front Panel LEDs continued Item LED Description Status 3 NIC 1* 4 NI

Strona 23 - Server Blade Operations

Server Blade Component Identification WARNING: Before removing a hard drive, read the hot-plug hard drive replacement section in the HP ProLiant Se

Strona 24

Server Blade Component Identification Table 1-2: Hot-Plug SCSI Hard Drive LED Status Combinations (1) Activity (2) Online (3) Fault Description On

Strona 25 - Server Blade Setup

Server Blade Component Identification Table 1-2: Hot-Plug SCSI Hard Drive LED Status Combinations continued (1) Activity (2) Online (3) Fault Descr

Strona 26

Server Blade Component Identification System Switches System switches enable you to change certain settings or to perform advanced diagnostic procedur

Strona 27 - Installing a Server Blade

Server Blade Component Identification System Maintenance Switch The system maintenance switch (SW2) is an eight-position switch that implements protec

Strona 28

© Copyright 2003-2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warrant

Strona 29 - Enclosure

Server Blade Component Identification Identifying System Board Components Use Figure 1-5 and Table 1-5 to identify the system board components and con

Strona 30 - Processors and Heatsinks

Server Blade Component Identification Table 1-5: System Board Components and Connectors continued Item Description 9 DC filter module 10 DIMM slots

Strona 31

Server Blade Component Identification HP ProLiant BL20p Generation 3 Server Blade User Guide 1-11 Table 1-6: Local I/O cable connectors

Strona 32 - Installing a Processor

2 Server Blade Operations Powering Up the Server Blade By default, server blades are set to power up automatically when installed in a server blade en

Strona 33

Server Blade Operations 2-2 HP ProLiant BL20p Generation 3 Server Blade User Guide For more information about iLO, refer to Chapter 5, “S

Strona 34 - Removing Hard Drive Blanks

3 Server Blade Setup Accessing Internal Server Blade Components WARNING: To reduce the risk of electric shock, do not power up the server blade wit

Strona 35 - SCSI ID Numbers

Server Blade Setup 4. Place the server blade on a flat, level surface. 5. Remove the access panel. Refer to “Removing the Server Blade Access Panel”

Strona 36

Server Blade Setup To install the access panel, reverse the removal procedure. Removing a Server Blade Blank CAUTION: Always populate the server bla

Strona 37

Server Blade Setup CAUTION: Always populate the server blade enclosure bays with either a server blade or server blade blank. Unpopulated bays can

Strona 38 - Installing DIMMs

Server Blade Setup HP ProLiant BL20p Generation 3 Server Blade User Guide 3-5 Removing a Server Blade from a Server Blade Enclosure 1.

Strona 39

Contents About This Guide Audience Assumptions... v

Strona 40 - Enabler

4 Hardware Options Installation Processors and Heatsinks The ProLiant BL20p G3 server blade ships with one or two processors. WARNING: To reduce th

Strona 41

Hardware Options Installation Installation and Upgrade Requirements Observe the following requirements before installing a processor in the server bla

Strona 42 - Array 6i controller

Hardware Options Installation Figure 4-2: Removing the processor Installing a Processor IMPORTANT: The processor and heatsink are designed to fit

Strona 43 - Adapter

Hardware Options Installation Figure 4-3: Installing a processor CAUTION: Be sure that the processor locking lever is closed. Do not force the le

Strona 44

Hardware Options Installation CAUTION: After the cover is removed, do not touch the thermal interface media. IMPORTANT: The heatsink is not reus

Strona 45 - Software and Utilities

Hardware Options Installation Figure 4-6: Removing a hard drive blank NOTE: Store the hard drive blank for future use. To install a hard drive bl

Strona 46

Hardware Options Installation CAUTION: If you are replacing a drive that is part of an array, refer to the HP ProLiant Servers Troubleshooting Guid

Strona 47

Hardware Options Installation 2. Insert the hot-plug SCSI hard drive. Be sure the drive seats firmly into the connector on the SCSI backplane (1). 3.

Strona 48

Hardware Options Installation Memory You can expand system memory by installing synchronous DDR DIMMs. A ProLiant BL20p G3 server blade supports up to

Strona 49 - Redundant ROM Support

Hardware Options Installation 1. Access the internal server blade components. Refer to “Accessing Internal Server Blade Components” in Chapter 3, “Se

Strona 50 - Remote ROM Flash

Contents Chapter 2 iv HP ProLiant BL20p Generation 3 Server Blade User Guide ROMPaq Utility ...

Strona 51 - ROM-Based Setup Utility

Hardware Options Installation Smart Array 6i 128-MB Battery-Backed Write Cache Enabler The optional Battery-Backed Write Cache Enabler provides the sy

Strona 52

Hardware Options Installation NOTE: Before removing the battery from the carrier, be sure to unwrap the cable. Figure 4-11: Removing the battery f

Strona 53

Hardware Options Installation Figure 4-12: Installing the battery onto the Smart Array 6i 128-MB Battery-Backed Write Cache Enabler Figure 4-13: I

Strona 54 - Fan Redundancy

Hardware Options Installation Figure 4-14: Installing the Smart Array 6i controller To reinstall the access panel, refer to “Accessing Internal Serv

Strona 55 - ProLiant Power Governor

Hardware Options Installation HP ProLiant BL20p Generation 3 Server Blade User Guide 4-15 To remove the access panel, refer to “Accessing

Strona 56 - Network-Based PXE Deployment

5 Server Blade Configuration and Utilities This chapter contains information about server blade deployment methods, hardware configuration, and the so

Strona 57

Server Blade Configuration and Utilities • Integrated Management Log (IML) HP also offers the following software components: • Health and Wellness D

Strona 58

Server Blade Configuration and Utilities Using a supported web browser, you can: • Remotely access the console of the host server blade, including al

Strona 59 - Diagnostics Utility

Server Blade Configuration and Utilities • Through the server blade rear panel connectors (out of the rack, with the diagnostic station): This method

Strona 60 - Automatic Server Recovery-2

Server Blade Configuration and Utilities • Enter a valid iLO user ID and password with the appropriate iLO privileges (Administer User Accounts, Conf

Strona 61 - Integrated Management Log

Contents Fan Redundancy ... 5-10 HP ProLiant BL20p G

Strona 62

Server Blade Configuration and Utilities 5. Press the Enter key. 6. Press the Esc key to exit the current menu or press the F10 key to exit RBSU. 7.

Strona 63

Server Blade Configuration and Utilities ROMPaq Utility Flash ROM enables you to upgrade the firmware (BIOS) with system or option ROMPaq utilities. T

Strona 64 - Static IP Bay Configuration

Server Blade Configuration and Utilities To navigate RBSU, use the following keys: • To access RBSU, use the iLO Remote Console and press the F9 key

Strona 65

Server Blade Configuration and Utilities Table 5-1: RBSU Default Settings continued Menu/Option Default Setting Wake-on LAN Enabled POST Speed Up E

Strona 66

Server Blade Configuration and Utilities Table 5-1: RBSU Default Settings continued Menu/Option Default Setting Virtual Install Disk Disabled Serial

Strona 67

Server Blade Configuration and Utilities ProLiant Power Governor The ProLiant Power Governor utility, which is located under the Advanced Option menu

Strona 68

Server Blade Configuration and Utilities Option ROM Configuration for Arrays Utility 5-12 HP ProLiant BL20p Generation 3 Server Blade User Guide

Strona 69

Server Blade Configuration and Utilities Deployment Infrastructure To establish a network-based PXE deployment infrastructure, you must provide the fo

Strona 70

Server Blade Configuration and Utilities — 10 Mb/s network adapter • PXE deployment server (storing boot images) — Intel Pentium III or higher proc

Strona 71

Server Blade Configuration and Utilities 1.4.2 for Linux users only Access the Java Runtime Environment versions at http://java.sun.com/products/arch

Strona 72 - Deployment Methods

Contents Cables... C-2 Canadian No

Strona 73

Server Blade Configuration and Utilities To run Diagnostics Utility: — Download the latest Diagnostics Utility from the HP website: www.hp.com/server

Strona 74

Server Blade Configuration and Utilities Integrated Management Log The IML records hundreds of events and stores them in an easy-to-view form. The IML

Strona 75

Server Blade Configuration and Utilities 3. Select Integrated Management Log. 4. If a failed component has been replaced, select the event from the

Strona 76

Server Blade Configuration and Utilities Table 5-2: Server Blade Event Messages continued Event Type Event Message Main Memory Correctable error th

Strona 77

Server Blade Configuration and Utilities Configuration and Deployment Overview Integrated Lights-Out Advanced (iLO Advanced) can be a helpful debuggin

Strona 78

Server Blade Configuration and Utilities Using the iLO static IP bay configuration will: • Help avoid the costs of a DHCP infrastructure to support t

Strona 79 - Connecting Local I/O Devices

Server Blade Configuration and Utilities HP recommends selecting a reasonable starting IP address, with the last digit(s) of the address corresponding

Strona 80

Server Blade Configuration and Utilities Figure 5-1: Static IP Bay Configuration screen HP ProLiant BL20p Generation 3 Server Blade User Guide 5-23

Strona 81

Server Blade Configuration and Utilities Standard Configuration Parameters 5-24 HP ProLiant BL20p Generation 3 Server Blade User Guide ga

Strona 82

Server Blade Configuration and Utilities Enable iLO IP Address Assignment To configure the BL p-Class server blades for IP address assignment: • Chec

Strona 83 - Keyboard, Video, and Mouse

About This Guide This guide provides step-by-step instructions for installation, and reference information for operation, troubleshooting, and future

Strona 84

Server Blade Configuration and Utilities • SLOT_ENABLE MASK enables the use of Static IP Bay Configuration 5-26 HP ProLiant BL20p Generation 3 Serve

Strona 85

Server Blade Configuration and Utilities <SEC_DNS_SERVER VALUE=""/> <TER_DNS_SERVER VALUE=""/> <PRIM_WINS_SERVER VA

Strona 86

Server Blade Configuration and Utilities Deployment Methods Four primary deployment methods are supported: IMPORTANT: To deploy a server blade with

Strona 87

Server Blade Configuration and Utilities The Altiris eXpress Deployment Server Console has an intuitive graphical user interface that provides simplif

Strona 88

Server Blade Configuration and Utilities CD-ROM Deployment CD-ROM Deployment involves using a bootable CD that executes script to configure the hardwa

Strona 89 - Table A-1: Diagnostic Steps

Server Blade Configuration and Utilities iLO Virtual CD-ROM To perform a boot CD deployment: 1. Do one of the following: — Insert the boot CD into t

Strona 90

Server Blade Configuration and Utilities 3. Reboot the server blade. 4. After the server blade boots, follow the normal installation procedure for a

Strona 91

Server Blade Configuration and Utilities For details, download the latest version of the SmartStart Scripting Toolkit from www.hp.com/servers/sstoolki

Strona 92

Server Blade Configuration and Utilities 5-34 HP ProLiant BL20p Generation 3 Server Blade User Guide 3. Click the Virtual Devices tab. 4

Strona 93

6 Connecting Local I/O Devices Use the local I/O cable to perform some server blade configuration and diagnostic procedures. Connecting to a Server B

Strona 94

About This Guide This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personn

Strona 95

Connecting Local I/O Devices 1. Connect one end of the RJ-45 network cable to the local I/O cable (1). 2. Connect the other end of the network cable

Strona 96 - Power Converter Module LED

Connecting Local I/O Devices 3. Connect the local I/O cable to the I/O port on the server blade. CAUTION: Disconnect the local I/O cable from the

Strona 97

Connecting Local I/O Devices Connecting Directly to a Server Blade using Video and USB Devices To connect directly to the server blade, use the local

Strona 98

Connecting Local I/O Devices Directly Accessing a Configured Server Blade with Local Keyboard, Video, and Mouse CAUTION: Disconnect the local I/O c

Strona 99

Connecting Local I/O Devices Directly Accessing a Server Blade with Local Media Devices Use the following setup to configure a server blade or load so

Strona 100 - Server Blade Troubleshooting

Connecting Local I/O Devices HP ProLiant BL20p Generation 3 Server Blade User Guide 6-7 4. Connect the following to the USB hub: a. USB

Strona 101 - Problems After Initial Boot

A Server Blade Troubleshooting Server Blade Error Messages Use POST error messages to assist in troubleshooting and performing basic diagnostic functi

Strona 102 - Battery Replacement

Server Blade Troubleshooting When the Server Blade Does Not Start This section provides systematic instructions on what to try and where to go for hel

Strona 103 - Figure B-1: Battery holder

Server Blade Troubleshooting 5. Be sure the server blade is not rebooting repeatedly: a. Be sure that the system is not rebooting due to a problem t

Strona 104 - Modifications

Server Blade Troubleshooting f. iLO initialization g. Array controller initialization h. PXE initialization 9. The operating system loads to compl

Strona 105 - European Union Notice

About This Guide Rack Stability WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are

Strona 106 - Battery Replacement Notice

Server Blade Troubleshooting Table A-2: Is the Server Blade Power on/standby LED Illuminated? Answer Possible Reasons Possible Solutions No A broke

Strona 107

Server Blade Troubleshooting Table A-3: Is the Server Blade Power on/standby LED Green? Answer Possible Reasons Possible Solutions No, it is amber

Strona 108 - Electrostatic Discharge

Server Blade Troubleshooting Table A-4: Is the Server Blade Health LED Solid Green? Answer Possible Reasons Possible Solutions No, it is amber. A

Strona 109 - Grounding Methods

Server Blade Troubleshooting Table A-4: Is the Server Blade Health LED Solid Green? continued Answer Possible Reasons Possible Solutions If the h

Strona 110

Server Blade Troubleshooting Table A-4: Is the Server Blade Health LED Solid Green? continued Answer Possible Reasons Possible Solutions No, it is fl

Strona 111

Server Blade Troubleshooting Table A-4: Is the Server Blade Health LED Solid Green? continued Answer Possible Reasons Possible Solutions No, it is re

Strona 112

Server Blade Troubleshooting Table A-5: Is the iLO Remote Console Displaying Error Information? Answer Solution No An iLO problem exists. Refer to

Strona 113

Server Blade Troubleshooting Figure A-1: Power converter module LED location Table A-6: Power Converter Module Troubleshooting Table Status Descri

Strona 114

Server Blade Troubleshooting System Maintenance Switch Procedures When you perform troubleshooting steps, this guide may instruct you to perform the f

Strona 115

Server Blade Troubleshooting 6. Connect the server blade to system power using one of the following procedures: — Install the server blade in the se