Hp ProLiant DL380 G6 Server Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Hp ProLiant DL380 G6 Server. HP ProLiant DL380 G6 Server User Manual [en] [es] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
HP ProLiant DL380 G6 Server
User Guide
Abstract
This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment and
trained in recognizing
hazards in products with hazardous energy levels and are familiar with weight and stability precautions for rack installations.
Part Number: 495624-003
February 2011
Edition: 3
Przeglądanie stron 0
1 2 3 4 5 6 ... 116 117

Podsumowanie treści

Strona 1 - User Guide

HP ProLiant DL380 G6 Server User Guide Abstract This guide is for an experienced service technician. HP assumes you are qualified in the servicing o

Strona 2

Component identification 10 Item Description Status 1 NIC link/activity LED Green = Network link Flashing green = Network link and activity Off

Strona 3 - Contents

Electrostatic discharge 100 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions y

Strona 4 - Contents 4

Specifications 101 Specifications Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (50°F to 95°F) Shi

Strona 5 - Contents 5

Specifications 102 Rated input current 10 A at 100 VAC 4.9 A at 200 VAC Rated input power 930 W at 100V AC input 1348 W at 200V AC input BTUs per ho

Strona 6 - Contents 6

Specifications 103 Rated steady-state power 460 W at 100V to 120V AC input 460 W at 200V to 240V AC input Maximum peak power 460 W at 100V to 120V A

Strona 7 - Component identification

Technical support 104 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical s

Strona 8 - Front panel LEDs and buttons

Technical support 105 • Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, howe

Strona 9 - Systems Insight Display LEDs

Technical support 106 Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzion

Strona 10

Technical support 107 CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte Standort

Strona 11 - Rear panel components

Technical support 108 Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedo

Strona 12 - Rear panel LEDs and buttons

Technical support 109 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente

Strona 13 - System board components

Component identification 11 Systems Insight Display LED and color Health LED System power LED Status Power supply (amber) Red Amber • Only one po

Strona 15 - NMI functionality

Technical support 111

Strona 16 - SAS and SATA device numbers

Acronyms and abbreviations 112 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protection ASR A

Strona 17 - SAS and SATA hard drive LEDs

Acronyms and abbreviations 113 ISEE Instant Support Enterprise Edition NFPA National Fire Protection Association NMI non-maskable interrupt NVRAM

Strona 18 - PCI riser cage LEDs

Acronyms and abbreviations 114 SAS serial attached SCSI SDDC Single Device Data Correction SDRAM synchronous dynamic RAM SFF small form-factor S

Strona 19 - Battery pack LEDs

Index 115 A access panel 23, 24 air baffle 27 Array Configuration Utility (ACU) 68 ASR (Automatic Server Recovery) 69 authorized reseller

Strona 20 - Hot-plug fans

Index 116 health LEDs 8, 15, 80 help resources 104 HP Insight Diagnostics 72 HP technical support 104 I identification number 94 iLO (Inte

Strona 21

Index 117 resetting the system 15 ROM redundancy 71 ROMPaq utility 70, 71 S safety considerations 31, 75 SAS drive numbers 18 SAS hard dri

Strona 22 - Operations

Component identification 12 10 Video connector 11 NIC 1 connector 12 NIC 2 connector 13 Mouse connector 14 Keyboard connector 15 Serial connector 16

Strona 23 - Remove the access panel

Component identification 13 Primary (slot - form factor) Secondary (slot - form factor) PCIe riser slot description PCIe x16 riser slot descriptio

Strona 24 - Install the access panel

Component identification 14 Item Description 1 Processor 2 DIMM slots 2 SAS power connector A 3 SAS power connector B 4 Front I/O connector 5 SATA

Strona 25

Component identification 15 Position Default Function S3 Off Reserved S4 Off Reserved S5 Off Off = Power-on password is enabled. On = Power-on

Strona 26 - Install the PCI riser cage

Component identification 16 DIMM slot locations DIMM slots are numbered sequentially (1 through 9) for each processor. The supported AMP modes use t

Strona 27 - Remove the air baffle

Component identification 17 • Optional SFF device bay numbering • LFF device bay numbering SAS and SATA hard drive LEDs Item Description

Strona 28 - Rack planning resources

Component identification 18 SAS and SATA hard drive LED combinations Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation On,

Strona 29 - Optimum environment

Component identification 19 Status On = AC power is connected. Off = AC power is disconnected. Missing = Riser is not installed and power

Strona 30 - Power requirements

© Copyright 2009, 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Strona 31 - Installing hardware options

Component identification 20 Item ID Color Description 2 Green Auxiliary Power LED. This LED glows steadily when 3.3V auxiliary voltage is detecte

Strona 32

Component identification 21 The only two valid fan configurations are listed in the following table. Configuration Fan bay 1 Fan bay 2 Fan bay 3

Strona 33 - Setup 33

Operations 22 Operations Power up the server To power up the server, press the Power On/Standby button. Power down the server WARNING: To reduc

Strona 34 - Registering the server

Operations 23 3. After performing the installation or maintenance procedure, slide the server back into the rack, and then press the server firm

Strona 35 - Processor option

Operations 24 1. Power down the server if performing a non-hot-plug installation or maintenance procedure ("Power down the server" on page

Strona 36

Operations 25 2. Open the cable management arm. Cable management arm with right-hand swing NOTE: To access some components, you may need to r

Strona 37

Operations 26 Remove the PCI riser cage CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all AC po

Strona 38

Operations 27 3. Install the server into the rack. 4. Power up the server (on page 22). Remove the air baffle CAUTION: For proper cooling do n

Strona 39

Setup 28 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and

Strona 40 - Install the heatsink

Setup 29 Optimum environment When installing the server in a rack, select a location that meets the environmental standards described in this sectio

Strona 41 - Memory options

Contents 3 Contents Component identification ...

Strona 42

Setup 30 Temperature requirements To ensure continued safe and reliable equipment operation, install or position the system in a well-ventilated, cl

Strona 43 - Memory configurations

Setup 31 Because of the high ground-leakage currents associated with multiple servers connected to the same power source, HP recommends the use of a

Strona 44

Setup 32 CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the rack. Install the heaviest item first, and c

Strona 45

Setup 33 6. Connect the power cord to the AC power source. WARNING: To reduce the risk of electric shock or damage to the equipment: • Do n

Strona 46

Setup 34 To configure these utilities manually: • Press the F8 key when prompted during the array controller initialization to configure the array

Strona 47

Hardware options installation 35 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Strona 48 - Installing a DIMM

Hardware options installation 36 6. Open the heatsink retaining bracket, and then remove the processor blank. CAUTION: The pins on the processo

Strona 49

Hardware options installation 37 8. If the processor has separated from the installation tool, carefully re-insert the processor in the tool. Handle

Strona 50 - Optical drive option

Hardware options installation 38 9. Align the processor installation tool with the socket, and then install the processor. THE PINS ON THE SYSTEM BO

Strona 51

Hardware options installation 39 10. Press the tabs on the processor installation tool to separate it from the processor, and then remove the tool.

Strona 52

Contents 4 Hardware options installation ... 35

Strona 53 - Expansion board options

Hardware options installation 40 CAUTION: After the cover is removed, do not touch the thermal interface media. 13. Install the heatsink.

Strona 54

Hardware options installation 41 14. Close the heatsink retaining bracket. 15. Remove the fan blanks in bays 5 and 6. For fan location and numberi

Strona 55

Hardware options installation 42 IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the se

Strona 56 - PCI riser board option

Hardware options installation 43 DIMM identification IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these t

Strona 57 - Hard drive cage option

Hardware options installation 44 • Lockstep—provides enhanced protection while making all installed memory available to the operating system. The s

Strona 58

Hardware options installation 45 Lockstep mode uses channel 1 and channel 2. Channel 3 is not populated. Because channel 3 cannot be populated when

Strona 59

Hardware options installation 46 Mirrored Memory population guidelines For Mirrored Memory mode configurations, observe the following guidelines: •

Strona 60

Hardware options installation 47 Lockstep Memory population guidelines For Lockstep memory mode configurations, observe the following guidelines: •

Strona 61

Hardware options installation 48 Installing a DIMM CAUTION: To avoid damage to the hard drives, memory, and other system components, the air baf

Strona 62

Hardware options installation 49 Installing a hot-plug SAS hard drive 1. Remove the SAS hard drive blank. 2. Prepare the hard drive. 3. Install

Strona 63 - Cabling

Contents 5 ProLiant Support Packs ...

Strona 64 - BBWC battery cabling

Hardware options installation 50 CAUTION: For proper cooling do not operate the server without the access panel, baffles, expansion slot covers, o

Strona 65 - Configuration and utilities

Hardware options installation 51 5. Slide the optical drive into the drive bay. 6. Connect the power and data cable to the system board. The air b

Strona 66 - HP ROM-Based Setup Utility

Hardware options installation 52 9. Power up the server (on page 22). Redundant hot-plug power supply option CAUTION: To prevent improper cooli

Strona 67 - Configuring mirrored memory

Hardware options installation 53 5. Route the power cord through the power cord anchor or cable management arm. 6. Reposition the cable management

Strona 68 - Array Configuration Utility

Hardware options installation 54 o To remove slot covers 2 and 3, lift up on the latch, remove the latch, and then remove the cover. o To remove s

Strona 69 - Management tools

Hardware options installation 55 7. Connect any required internal or external cables to the expansion board. See the documentation that ships with t

Strona 70 - Erase Utility

Hardware options installation 56 9. Close the full-length expansion board retainer. 10. Connect any required internal or external cables to the ex

Strona 71 - Internal SD support

Hardware options installation 57 5. Install the optional riser board. 6. Install any expansion boards. ("Expansion board options" on pag

Strona 72 - Diagnostic tools

Hardware options installation 58 6. Remove the two primary hard drive retaining screws and slide the cage forward. 7. Install the optional hard dr

Strona 73 - Keeping the system current

Hardware options installation 59 12. Connect one end of the power cable to the SAS backplane and the other end to the system board. 13. Install th

Strona 74 - Care Pack

Contents 6 Technical support ...

Strona 75 - Troubleshooting

Hardware options installation 60 HP Trusted Platform Module option Use these instructions to install and enable a TPM on a supported server. This pr

Strona 76 - Warnings and cautions

Hardware options installation 61 4. Remove the access panel (on page 23). 5. Remove the PCI riser cage (on page 26). 6. Remove the air baffle (on

Strona 77 - Symptom information

Hardware options installation 62 Retaining the recovery key/password The recovery key/password is generated during BitLocker™ setup, and can be save

Strona 78

Cabling 63 Cabling SAS hard drive cabling Optical drive cabling

Strona 79 - Loose connections

Cabling 64 BBWC battery cabling

Strona 80 - Troubleshooting flowcharts

Configuration and utilities 65 Configuration and utilities Configuration tools SmartStart software SmartStart is a collection of software that optim

Strona 81 - General diagnosis flowchart

Configuration and utilities 66 refer to the SmartStart Scripting Toolkit User Guide on the HP website (http://h18004.www1.hp.com/products/servers/ma

Strona 82

Configuration and utilities 67 NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically configure the

Strona 83 - Symptoms:

Configuration and utilities 68 7. Press the Esc key to exit the current menu or press the F10 key to exit RBSU. For more information on mirrored mem

Strona 84

Configuration and utilities 69 The utility also provides support for the following functions: • Reconfiguring one or more logical drives • Viewing

Strona 85 - Troubleshooting 85

Component identification 7 Component identification Front panel components • SFF model Item Description 1 Quick release levers (2) 2 Systems

Strona 86 - POST problems flowchart

Configuration and utilities 70 ASR increases server availability by restarting the server within a specified time after a system hang or shutdown. A

Strona 87

Configuration and utilities 71 To access the Erase Utility, use the System Erase button on the home screen of the SmartStart CD ("SmartStart so

Strona 88 - OS boot problems flowchart

Configuration and utilities 72 Diagnostic tools HP Insight Diagnostics HP Insight Diagnostics is a proactive server management tool, available in bo

Strona 89 - Troubleshooting 89

Configuration and utilities 73 Remote support and analysis tools HP Insight Remote Support software HP strongly recommends that you install HP Insig

Strona 90 - • Redundancy failure

Configuration and utilities 74 ProLiant Support Packs PSPs represent operating system-specific bundles of ProLiant optimized drivers, utilities, and

Strona 91 - (http://www.hp.com/support)

Troubleshooting 75 Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common

Strona 92 - Troubleshooting 92

Troubleshooting 76 Symbols on equipment The following symbols may be placed on equipment to indicate the presence of potentially hazardous condition

Strona 93 - Battery replacement

Troubleshooting 77 WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The

Strona 94 - Class B equipment

Troubleshooting 78 2. Record any error messages displayed by the system. 3. Remove all diskettes, CD-ROMs, DVD-ROMs, and USB drive keys. 4. Power

Strona 95 - Modifications

Troubleshooting 79 When requested to break the server down to the minimum configuration, uninstall the following components, if installed: • All ad

Strona 96 - • EMC Directive 2004/108/EC

Component identification 8 Item Description 6 USB connectors (2) • LFF model Item Description 1 Quick release levers (2) 2 Systems Insight D

Strona 97 - Japanese notice

Troubleshooting 80 Service notifications To view the latest service notifications, refer to the HP website (http://www.hp.com/go/bizsupport). Select

Strona 98 - Battery replacement notice

Troubleshooting 81 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure o

Strona 99

Troubleshooting 82 Item See 5 "General memory problems are occurring" in the HP ProLiant Servers Troubleshooting Guide located on the Doc

Strona 100 - Electrostatic discharge

Troubleshooting 83 Server power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber.

Strona 101 - Specifications

Troubleshooting 84 • The external health LED is red or amber. • The internal health LED is red or amber. NOTE: For the location of server LED

Strona 102

Troubleshooting 85

Strona 103

Troubleshooting 86 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system att

Strona 104 - Technical support

Troubleshooting 87 Item See 13 • "Server information you need" in the HP ProLiant Servers Troubleshooting Guide located on the Documenta

Strona 105 - Technical support 105

Troubleshooting 88 OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system • Server does not boot Smar

Strona 106 - Customer Self Repair

Troubleshooting 89 Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by Insight Management Agents • Ser

Strona 107 - Technical support 107

Component identification 9 Item Description Status 2 System health LED Green = Normal Amber = System degraded. Red = System critical. To identi

Strona 108 - Reparo feito pelo cliente

Troubleshooting 90 Possible causes: • Improperly seated or faulty internal or external component • Unsupported component installed • Redundancy f

Strona 109 - Technical support 109

Troubleshooting 91 POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in th

Strona 110 - Technical support 110

Troubleshooting 92 WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before re

Strona 111 - Technical support 111

Battery replacement 93 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the bat

Strona 112 - Acronyms and abbreviations

Regulatory compliance notices 94 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance

Strona 113

Regulatory compliance notices 95 radio communications. However, there is no guarantee that interference will not occur in a particular installation.

Strona 114

Regulatory compliance notices 96 This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. C

Strona 115 - Index 115

Regulatory compliance notices 97 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other

Strona 116 - Index 116

Regulatory compliance notices 98 Class B equipment Chinese notice Class A equipment Laser compliance This product may be provided with an optica

Strona 117 - Index 117

Regulatory compliance notices 99 For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized

Komentarze do niniejszej Instrukcji

Brak uwag