Hp ProLiant ML115 Server Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Hp ProLiant ML115 Server. HP ProLiant ML115 Server User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 58
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
nForce Software for Linux
MediaShield Users
Guide
Version 1.0
NVIDIA Corporation
February 13, 2007
Przeglądanie stron 0
1 2 3 4 5 6 ... 57 58

Podsumowanie treści

Strona 1 - MediaShield User’s

nForce Software for LinuxMediaShield User’s GuideVersion 1.0NVIDIA CorporationFebruary 13, 2007

Strona 2

6 MediaShield User’s Guide – Version 1.0CHAPTER 1About NVIDIA® MediaShield™NVIDIA MediaShield FeaturesAdditional RAID FeaturesNVIDIAMediaShieldoffer

Strona 3 - 3.Creating RAID Arrays

NVIDIA Corporation 7C HAPTERCONFIGURING THE BIO SThischapterprovidesinstructionsfortwobasicBIOSconfigurationtasks:• EnablingRAIDintheSyst

Strona 4

8 MediaShield User’s Guide – Version 1.0CHAPTER 2Configuring the BIOSEnabling RAID in the System BIOS1 Startyourcomputer,thenpressDeletetoenter

Strona 5 - MEDIASHIELD™

NVIDIA Corporation 9CHAPTER 2Configuring the BIOSTheIntegratedPeripheralswindowappears.Figure 2.2Integrated Peripherals Window3 Usethearrowkeys

Strona 6 - Table 1.1

10 MediaShield User’s Guide – Version 1.0CHAPTER 2Configuring the BIOS4 FromtheRAIDConfigwindow,globallyenableRAID,thenenabletheSATAports

Strona 7 - RAID Arrays

NVIDIA Corporation 11CHAPTER 2Configuring the BIOSCreating a RAID Array Using the RAID BIOSTheNVIDIARAIDBIOSsetupletsyouchoosetheRAIDtypean

Strona 8 - RAID 0+1

12 MediaShield User’s Guide – Version 1.0CHAPTER 2Configuring the BIOSUnderstanding the Define a New Array WindowUsetheDefineaNewArraywindowto•

Strona 9 - About NVIDIA® MediaShield™

NVIDIA Corporation 13CHAPTER 2Configuring the BIOSAssigning the DisksThedisksthatyouenabledfromtheRAIDConfigBIOSsetuppageappearintheFre

Strona 10 - Disk Failure Identification

14 MediaShield User’s Guide – Version 1.0CHAPTER 2Configuring the BIOSCompleting the RAID BIOS Setup1 AfterassigningyourRAIDarraydisks,pressF7.

Strona 11 - ONFIGURING

NVIDIA Corporation 15CHAPTER 2Configuring the BIOS3 Usethearrowkeystoselectthearraythatyouwanttosetup,thenpressBtospecifythearray

Strona 12 - Figure 2.1

NVIDIA Applications MediaShield User’s Guide Version 1.0Published byNVIDIA Corporation 2701 San Tomas ExpresswaySanta Clara, CA 95050NoticeALL NVIDIA

Strona 13 - Figure 2.3

16 MediaShield User’s Guide – Version 1.0CHAPTER 2Configuring the BIOS

Strona 14 - Configuring the BIOS

NVIDIA Corporation 17C HAPTERCREATING RAID ARRAYSThischapterprovidesinstructionsoncreatingbootableandnon‐bootableRAIDarrays.• CreatingaBoo

Strona 15 - Figure 2.4

18 MediaShield User’s Guide – Version 1.0CHAPTER 3Creating RAID Arrays2 InstalltheOSInserttheLinuxOSinstalldiscintotheCD/DVDROMdrive,then

Strona 16 - Figure 2.5

NVIDIA Corporation 19CHAPTER 3Creating RAID Arraysc InsertyourSATAdriverdisketteintothefloppydriveandpress“OK”tocontinue.d Continuewith

Strona 17 - Figure 2.6

20 MediaShield User’s Guide – Version 1.0CHAPTER 3Creating RAID Arraysc IfaʺDriverDiskSourceʺdialogboxappears,selectʺfd0ʺandpressʺOKʺ.d At

Strona 18 - Figure 2.8

NVIDIA Corporation 21CHAPTER 3Creating RAID ArraysCreating a Non-Bootable ArrayStep 1: Enable RAID in the system BIOSSee“EnablingRAIDintheSystem

Strona 19 - Figure 2.9

22 MediaShield User’s Guide – Version 1.0CHAPTER 3Creating RAID ArraysUsing the MediaShield Utility1 InstalltheNVIDIARAIDdriversThe\rpmfolderco

Strona 20

NVIDIA Corporation 23C HAPTERINSTALLING AND USING THE NVIDIAMEDIASHIELD APPLICATIONTheNVIDIARAIDdriverpackageincludestheMediaShieldapplication

Strona 21 - CREATING RAID ARRAYS

24 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationInstalling the NVIDIA MediaShield Application

Strona 22 - ForSLESandSuSELinux:

NVIDIA Corporation 25CHAPTER 4Installing and Using the NVIDIA MediaShield Application• Name:IndicatestheRAIDarraytype,drivemodelinformation,w

Strona 23 - Creating RAID Arrays

NVIDIA CorporationDrivers for Windows® MediaShield User’s Guide Version 1.01.About NVIDIA® MediaShield™System Requirements . . . . . . . . .

Strona 24

26 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationCreating an ArrayThisoptionisavailableonl

Strona 25 - Using the RAID BIOS

NVIDIA Corporation 27CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationTheRAIDArraySelectionpageappears.Figure 4.3RAID Array Select

Strona 26 - Using the MediaShield Utility

28 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield Application5 Selectthedisksthatyouwa nttoinclude

Strona 27 - SHIELD APPLICATION

NVIDIA Corporation 29CHAPTER 4Installing and Using the NVIDIA MediaShield Application7 ClickNext.TheCompletingtheNVIDIAMediaShieldSetupWizard

Strona 28 - Figure 4.1

30 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationDeleting an ArrayThisoptionisavailableonl

Strona 29 - NVIDIA Corporation 25

NVIDIA Corporation 31CHAPTER 4Installing and Using the NVIDIA MediaShield Application2 AttheWelcomepage,clickNext.TheCompletingtheNVIDIADele

Strona 30 - Figure 4.2

32 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationRebuilding an ArrayAbout RebuildingRebuilding

Strona 31 - Figure 4.4

NVIDIA Corporation 33CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationTheNVIDIARebuildArrayWizardopens.Figure 4.12Rebuild Array Wi

Strona 32 - Figure 4.6

34 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationTheCompletingtheNVIDIARebuildArraypage

Strona 33 - Figure 4.7

NVIDIA Corporation 35CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationSynchronizing an ArraySynchronizinganarraywillforcearebuild

Strona 34 - Figure 4.9

NVIDIA Applications MediaShield User’s Guide Version 1.0

Strona 35 - Figure 4.10

36 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationTheSynchronizeArrayWizardWelcomescreena

Strona 36 - Figure 4.11

NVIDIA Corporation 37CHAPTER 4Installing and Using the NVIDIA MediaShield Application4 ClickFinish.TheStatuscolumnforthearraybeingsynchronize

Strona 37 - Figure 4.13

38 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationManaging Spare DisksAbout Spare DisksYoucan

Strona 38 - Figure 4.15

NVIDIA Corporation 39CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationRequirements for Designating a Spare DiskTheDesignateSpareopti

Strona 39 - Figure 4.16

40 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationTheNVIDIASpareDiskAllocationWizard‐Welco

Strona 40 - Figure 4.18

NVIDIA Corporation 41CHAPTER 4Installing and Using the NVIDIA MediaShield Application4 ClickNext.TheCompletingtheNVIDIASpareDiskAllocationpage

Strona 41 - Figure 4.19

42 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationRemoving a Spare DiskTheRemovespareoption

Strona 42 - Dedicated Disks

NVIDIA Corporation 43CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationMigrating an ArrayInatraditionalRAIDenvironment,whenauser

Strona 43 - Figure 4.20

44 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationSpecific Migrating RequirementsThefollowing

Strona 44 - Figure 4.22

NVIDIA Corporation 45CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationMigrating Instructions1 GotothesystemBIOSandmakesurethat

Strona 45 - Figure 4.23

NVIDIA Corporation 1C HAPTERABOUT NVIDIA® MEDIASHIELD™NVIDIAbringsRedundantArrayofIndependentDisks(RAID)technology—whichisusedbytheworld’

Strona 46 - Figure 4.24

46 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield Application3 ClickNext.TheRAIDModeSelectionpageapp

Strona 47 - Migrating an Array

NVIDIA Corporation 47CHAPTER 4Installing and Using the NVIDIA MediaShield Application5 Selectadditionaldisks,ifneeded.Forexample,• Ifyouwantt

Strona 48 - Table 4.1

48 MediaShield User’s Guide – Version 1.0CHAPTER 4Installing and Using the NVIDIA MediaShield ApplicationThenewRAIDarrayappearsintheStorageMan

Strona 49 - Figure 4.26

NVIDIA Corporation 49C HAPTERMEDIASHIELD RAID FREQUENTLY ASKEDQUESTIONSTheFAQinthischapterareorganizedbythefollowingcategories:• BasicRAID

Strona 50 - Figure 4.28

50 MediaShield User’s Guide – Version 1.0CHAPTER 5MediaShield RAID Frequently Asked QuestionsBasic RAID Questions•WhatisRAID?RAIDstandsforRedunda

Strona 51 - Figure 4.29

NVIDIA Corporation 51CHAPTER 5MediaShield RAID Frequently Asked Questions•WhyisthecumulativesizeofaRAID0(Stripe)orRAID0+1(Stripe‐Mirror)

Strona 52 - HAPTER 4

52 MediaShield User’s Guide – Version 1.0CHAPTER 5MediaShield RAID Frequently Asked QuestionsDedicated Disk Questions•CanIassignaded icateddiskt

Strona 53

NVIDIA Corporation 53CHAPTER 5MediaShield RAID Frequently Asked QuestionsMediaShield Application Questions•WhatfunctionscanbeperformedusingtheM

Strona 54 - Basic RAID Questions

54 MediaShield User’s Guide – Version 1.0CHAPTER 5MediaShield RAID Frequently Asked QuestionsKnown Issues•TheNVIDIAMediaShieldapplicationrequires

Strona 55 - Rebuilding Arrays Questions

2 MediaShield User’s Guide – Version 1.0CHAPTER 1About NVIDIA® MediaShield™System RequirementsHardware SupportTable1.1liststheNVIDIA®nForce™plat

Strona 56 - Array Migrating Questions

NVIDIA Corporation 3CHAPTER 1About NVIDIA® MediaShield™RAID ArraysThissectiondescribesthefollowingtypesofRAIDarraysthatNVIDIAMediaShieldSt

Strona 57 - NVIDIA Corporation 53

4 MediaShield User’s Guide – Version 1.0CHAPTER 1About NVIDIA® MediaShield™RAID 1InaRAID1array,everyreadandwriteiscarriedoutinparallelac

Strona 58 - Known Issues

NVIDIA Corporation 5CHAPTER 1About NVIDIA® MediaShield™Summary of RAID ConfigurationsTable 1.2RAID Configuration SummaryArray Uses Advantages Drawbac

Komentarze do niniejszej Instrukcji

Brak uwag