Hp ProLiant ML370 G6 Server Instrukcja Użytkownika Strona 71

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 70
Hardware options installation 71
13.
Connect the drive cage bay 3 power cable (BP3) to the two-bay LFF drive cage backplane.
14. Connect the two-bay LFF drive cage to one of the following:
o A six-bay LFF backplane. See step 15.
o An optional SAS controller. See step 16.
15. Connect the SAS/SATA controller cable:
a. Connect the "6LFF" labeled connector to SAS connector 5-6 on the six-bay LFF backplane.
b. Connect the "2LFF" labeled connector to the two-bay LFF drive cage backplane.
c. Connect the remaining connector to SAS connector B on the system board.
Przeglądanie stron 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 171 172

Komentarze do niniejszej Instrukcji

Brak uwag