Hardware options installation 31
DIMM slots
DIMM slots are identified by the numbers 1 through 6. DIMM population order is specified by the letters A
through F.
Installing a DIMM
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
To install the component:
1. Power down the server (on page 15).
2. Disconnect all peripheral cables from the server.
3. Remove the server from the chassis ("Removing the server from the chassis" on page 15).
4. Open the DIMM slot latches.