edge switch 2/16 product manager user guide 1–31
Product Manager Overview
If a gray square displays in the status bar (no Ethernet connection), a reason for the
status displays in the Status table at the top of the Hardware View. Refer to No Link
Status on page 2-2 for details.
Table 1–1: Operating Status - Status Bar and Switch Status
Symbol Status Bar
Switch Status
Table Text Meaning
Green Circle Fully Operational All components and installed
ports are operational; no
failures.
Yellow
Triangle
Redundant Failure A redundant component has
failed, such as a power supply,
and the backup component
has taken over operation.
Minor Failure A failure occurred which has
decreased the switch
operational ability. Normal
switching operations are not
affected.
One or more ports failed,
but at least one port is still
operational.
A fan has failed or is not
rotating sufficiently.
Red
Diamond
with Yellow
Background
Not Operational A critical failure prevents the
switch from performing
fundamental switching
operations.
All fans failed.
All installed ports failed.
Both power supplies failed.